Alpha Fan Ally-5b-56 Led 5 Blades 56 Inch Dc Motor Matt Black Ceiling Fan Instruction Manual

ALLY-5B-56 LED 5 Blades 56 Inch DC Motor Matt Black Ceiling Fan

Product Information:

Version: 2022 V1

Models: ALLY-5B/56 LED, ALLY-5B/42 LED

Product Usage Instructions:

Transmitter Learning Process & Function Power Supply
Connection & Circuit Diagram

1. Installation and maintenance work should only be performed by
qualified persons who are familiar with local code and regulations
and experienced with this type of appliance.

2. All field wiring must be installed in accordance with the
national wiring regulations.

3. Before commencing wiring work according to the wiring
diagram, ensure that the rated voltage of the unit corresponds to
that of the nameplate.

4. The appliance must be permanently connected to the
electricity supply through a double pole switch with a contact
separation of at least 3mm in all poles.

5. The unit must be grounded to prevent possible hazards due to
insulation failure. The earth wire should be approximately 60mm
longer than the safety wire to ensure that in the event of
suspension system failure, the (L) and (N) wire will break, leaving
the fan earthed to prevent electrocution.

6. Tighten the blade firmly using a screwdriver. Blades that
become detached from the unit during operation can cause serious
injuries and property damage.

7. This appliance is not intended for use by persons (including
children) with reduced physical, sensory, or mental capabilities,
or lack of experience and knowledge, unless they have been given
supervision or instruction concerning the use of the appliance by a
person responsible for their safety.

8. Children should be supervised to ensure that they do not play
with the appliance.

9. Confirm that the power supply has been switched OFF before
installing or servicing the unit. Ensure that the blade is fully
static before performing any maintenance work.

10. STOP using the ceiling fan when any abnormality or failure
occurs. If unusual oscillating movement is observed, immediately
stop using the ceiling fan and contact the manufacturer, its
service agent, or suitably qualified persons.

Assembly Instructions:

1. Assemble the Canopy and Coupling Cover through the
Downrod.

2. Remove the Bolt, Washer, Nut, Clevis Pin, and Rubber Pulley
from the downrod.

3. Place the Rubber Pulley onto the ceiling hook and fix back
the Bolt, Washer, Nut, and Clevis Pin.

4. Remove the Safety Wire screw and spring washer from the
Downrod.

5. Tie the Safety Wire across the hook as shown and firmly screw
the Safety Wire onto the Downrod.

6. Fix the Rubber Pulley Assembly to the Downrod with Bolt,
Washer, Nut, and tighten them firmly. Then insert the Clevis Pin
and Washer. IMPORTANT: CLEVIS PIN MUST BE INSERTED TO PREVENT NUT
FROM LOOSENING.

Connection Instructions:

Step 4:

a. Connect the Connectors from Fan and Receiver.

b. Connect the wires from the receiver to House’s Supply
Wire.

c. Connect Earth Wire to House Supply Earth Terminal.

Circuit Diagram:

Circuit Diagram

Blade Installation:

Step 5:

a. Install the Blades on Motor with Blade Screw and Washer.

b. Use two pieces of Blade Screw and Washer for each Fan
Blade.

Version: 2022 V1

Model : ALLY-5B/56 LED ALLY-5B/42 LED

Transmitter Learning Process & Function Power Supply Connection & Circuit Diagram

1 – 2 3 4 – 6 7 – 8 9 – 10 10 11 12

Warning
Installation and maintenance work shall only be performed by qualified persons, familiar with local code and regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
The appliance must be permanently connected to the electricity supply through a double pole switch having a contact separation of at least 3mm in all poles.
The unit must be GROUNDED to prevent possible hazard due to insulation failure. The earth wire is approximately 60mm longer than safety wire. This is to ensure at the event whereby the suspension system fails, the (L) and (N) wire will break leaving the fan remain earthed to prevent electrocution.
Tighten the blade firmly using a screw driver. Blades that are detached from the unit during operation will cause serious injuries and property damages.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliances.
Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that the blade is fully static before doing any maintenance work.
STOP using the ceiling fan when any abnormality or failure occurs. If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.

SAFETY PRECAUTION
CAUTION
Please take note of the following important points when installing. The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan. The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons. The fan is to be installed so that the blades are more than 2.5m above the floor. Safety cord should not be longer than the earthing conductor. Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing conductor. The earthing terminal in the fan assembly should be such that should any part of the suspension system fall off, the body of the fan assembly shall effectively earthed. Ensure that the unit’s panel is closed after service or installation. Unsecured panels will cause the unit to operate noisily. Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places. Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF” position. If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user. Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction. Avoid the ceiling fan unit from exposing to direct sunlight, this may cause degradation of plastic material as a rsult of excessive heat and UV radiation.
Ensure the colour of wires of the outdoor unit and the terminal markings are same to the indoors respectively. Don’t use joined and twisted wires for incoming power supply. Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan. The fan suspension system and blade screw tightening shall be examined yearly. Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons. Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.
2

781

6

2

543

Receiver

Transmitter & Holder x 1

Battery x 2
AAA AAA
Wall Screw x 2

3

Assemble the Canopy and Coupling Cover through the Downrod.
Safety Wire
Canopy
Downrod Coupling Cover

a. Remove the Bolt, Washer, Nut, Clevis Pin and Rubber Pulley from downrod.
b. Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Washer, Nut and Clevis Pin.
c. Remove the Safety Wire screw and spring washer from the Downrod.
d. Tie the Safety Wire across the hook as shown and firmly screw the Safety Wire onto the Downrod.

b.
Rubber Pulley

Washer

Nut Clevis Pin

Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, Nut and tighten them firmly then insert the Clevis Pin and Washer.

IMPORTANT : CLEVIS PIN MUST BE INSERTED

TO PREVENT NUT FROM LOOSENING.

d.

Safety Wire

Step 4 a. Connect the Connectors from Fan and Receiver. b. Connect the wires from the receiver to House’s Supply Wire. c. Connect Earth Wire to House Supply Earth Terminal.

House Supply Wires

Brown (L) Blue (N)

Green/Yellow (E)

Orange Blue

Orange Blue

Green/Yellow(E) Brown (L) Blue (N)

White White Yellow Yellow Grey Grey

Green/Yellow(E)

Step 5 a. Install the Blades on Motor with Blade Screw and Washer. b. Two pieces Blade Screw and Washer for each Fan Blade.

Bolt
Washer, Nut & Clevis Pin

4

5

Step 6 a. Install the LED Light Kit on Motor with Light Kit Screw. b. Install Lamp Shade by twisting in clockwise.

a.

b.

Step 7 Below shows a complete installation diagram

6

AAA

IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR. The receiver & transmitter is pre-programmed in factory. If you wish to control 2 or more fans using 1 transmitter, the below steps are required. DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS Step 1 a) Insert the 2 pcs of batteries (provided) into transmitter. b) Turn on the power supply (wall switch) to the fan. c) Within 30 sec, press and hold the “LEARN” button for 3 sec. Once the receiver has detected the frequency,
transmitter will “Beep Beep” twice. Programming process is completed and fan is ready to use. If the fan is not responding to the transmitter, repeat Step 1b.
Learn
Press and hold for 3 sec
Transmitter
7

AAA

Fan Speed 1 – Lowest speed 8 – Highest speed
Forward Reverse Anti-clockwise or clockwise rotation.
Light On/Off & LED light colour selection Warm, Daylight & White

781

6

2

543

Power Turn off fan
Natural Wind Fan speed changes within its range creating gentle sea-breeze effect
Timer On 1h – Fan turns on after 1 hour 3h – Fan turns on after 3 hours 6h – Fan turns on after 6 hours 8h – Fan turns on after 8 hours

The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, fan will operate as the last setting.
Function of Forward & Reverse
Fan must be turned on and rotating.
Press and hold Forward/Reverse button for 3 sec fan will slow down and then change direction (approx. 15 sec). When the fan is slowing down to change direction, the Fan Speed function is disabled until direction has been changed.

Earth

Regulator

Dimmer Switch

Double Pole Switch

220-240V~ 50Hz Power Supply

Single Pole Switch

Forward Fan rotates anti-clockwise blowing the air downwards creating the wind chill effect. Suitable for hot weather condition.

Reverse Fan rotates clockwise drawing the air towards the ceiling circulating the warm air downwards. This function works best at low speed. Suitable for air-conditioned condition.

8

9

Earth (Green/Yellow) Grey
Yellow White More than 2.5m (8′ 2″)

IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
DC Motor

Neutral (Blue) Live (Brown)
Earth (Green/Yellow)
Power Supply 220V-240V – 50Hz

Blue Brown Green/Yellow

24W

W

ANT

V

LED

U

Orange Blue

MAIN PCB N LED+
L LED-

Orange Blue

E

220V-240V~ 50Hz

MAINTENANCE
Due to the fan’s natural movement, connections may get loose after period of usage. To ensure a proper and safety usage, it is highly recommended to inspect and tighten all connections every 6 months.
Cleaning Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures are as follows : 1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution. 2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will
scratch the surface. 3. Do not bent the blades while cleaning. At the event where blades are bent or damage,
order new set of blades from service center or dealer shop. 4. There is no need to oil the fan.
10

Model No. of Blades Fan Width Motor RPM Voltage Motor Wattage LED Wattage Nett Weight

ALLY-5B/56 LED 5
1420mm (56″) 80 – 185
220 – 240V~ 50Hz 5W – 45W 24W 7.0kg

ALLY-5B/42 LED 5
1066mm (42″) 110 – 240
220 – 240V~ 50Hz 5W – 40W 24W 6.1kg

More than 1m

320mm (12.6″)

405mm (1′ 4″)

ALLY-5B/56 LED 1420mm (4′ 8″) ALLY-5B/42 LED 1066mm (3′ 6″)

11

If you need any technical assistance or faulty report, please contact our customer service centre at :

Alpha Home Appliances Sdn. Bhd. (390258-H)

Head Office : 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32, 40460 Shah Alam, Selangor.

Tel

: 03-5740 6666

Fax : 03-5740 8220

Website : www.alphamalaysia.com

Email : [email protected]

Johor Bahru : 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.

Tel

: 07-353 4833 / 4933

Fax : 07-355 4233

Melaka Tel

: 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.

: 06-292 6292 / 6293

Fax : 06-292 6296

Ipoh

: 11, Jalan Tasek Timur 5, Taman Tasek Indra, 31400 Ipoh, Perak.

Tel

: 05-545 2282 / 547 2282

Fax : 05-547 6282

Penang Tel

: 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang. : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966

Pahang Tel

: A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.

: 09-516 5226

Fax : 09-513 9226

12

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals