AR7104800G Deck Mount Pot Filler
Product Information: POT FILLER FAUCETS
The Pot Filler Faucets are designed for easy installation and
convenient usage. They deliver cold water from a main supply and
can be positioned above sinks or stoves. The spout is articulated,
allowing the outlet to be conveniently positioned above pots or
pans as required.
Installation Note: When installing on plasterboard walls (not
solid walls), it is important to ensure that appropriate
reinforcement is in place to ensure sufficient strength.
Cleaning and Care: This product should be cleaned with care.
While its finish is extremely durable, it can be damaged by harsh
abrasives or polish. To clean, simply wipe gently with a damp cloth
and blot dry with a soft towel.
Compliance: The faucet with a 1.8 GPM aerator is compliant with
California water efficiency regulations, California Proposition 65,
and the Federal Safe Drinking Water Act.
Water Pressure Improvement: In areas with extremely low water
pressure causing unsatisfactory faucet water flow, the aerator can
be replaced to improve the water flow.
Notice: This faucet is for cold water connection only. Drainage
below the faucet may cause water damage.
Product Usage Instructions
1. Before installing the valves, clean the water pipe thoroughly
to avoid dirt and deposits.
2. Simple on/off control: Rotate the handle 90 degrees (1/4
turn) to switch the faucet on or off.
3. To install the faucet:
- Screw the base (2) under the body of the faucet.
- Attach the O-ring (3) to the base, ensuring that the handle
stick is facing the correct direction. - Place the washer (2) over the mounting stud under the
sink. - Screw the hexagonal lock nut (3) onto the threaded rod (1) and
tighten.
4. When the sink hole size is 35mm, tighten the fixing nut (2)
to the thread rod (1) and keep it horizontal with the counter.
- Place the washer (3) and metal plate (4) over the mounting stud
under the sink. - Screw the hexagonal lock nut (5) onto the threaded rod (1) and
tighten.
5. Use the triangle fastener (2) when the thickness of the sink
requires it.
Note: It is recommended to read all instructions completely
before beginning the installation and to pay attention to all
warnings, care, and maintenance information provided in the user
manual.
POT FILLER FAUCETS
You may need
1.8GPM 6.8L/min
For easy installation of your faucet you will need:
To READ ALL the instructions completely before beginning.
To READ ALL warnings, care, and maintenanceinformation.
Application Faucet are designed for delivering cold water from a main supply. Faucet can be positioned above sinks or stoves and the articulated nature of the spout enables the outlet to be conveniently positioned above pots / pans as required.
Installation Note: When installing on plasterboard walls (not solid walls) it must be assured that an appropriate reinforcement is in place to ensure sufficient strength.
Flush pipes thoroughly!
Cleaning and Care Care should be given to the cleaning of this product. Although its finish is extremely durable, It can be damaged by harsh abrasives or polish. To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.
washer 1.8gpm aeratot
aeratot house
With 1.8 gpm are compliant with California water effi ciency regulations, Complies with California Proposition 65 and with the Federal Safe Drinking Water Act.
In areas with extremely low water pressure causing the faucet water flow to be unsatisfactory , replace the aerator to improve the water flow in the faucet.
ON OFF
unit:inch(mm) OFF
ON
16.2”(412mm) 18”(458mm)
9”(229mm) 20.1”(511mm)
Ø1.8” (Ø45mm)
G1/2 G1/2
2″(50mm) Max. deck Thickness
24″(600mm)
3/8″
Notice:
Cold water connection only
Simple on/off control by rotating handle 90 (1/4 turn)
Ø1-1.4″ Shut off both handle cartridges when not in (Ø25-35) use or left unattended. Improper use or inadequate
drainage below faucet may cause water damage.
Notice Before installing the valves,
1
clean the water pipe thoroughly
to avoid dirt and deposits.
1
1
3
4
ON OFF
2
1.Screw the base(2) under the body .
3
1.Make sure attach the O-ring(3) to the
base. 2. Make sure the handle stick is facing
user when it is off, turn the handle 90° clockwise to open the tap. Correct installation will aviod the stick touching wall.
2.A
2.B
1
Hole size:Ø1″
2
(Ø25mm)
3
1.Place washer(2) over mounting stud under sink. 2.Screw hexagonal lock nut (3) on to threaded rod (1) and tighten.
1
2
Hole size:Ø1.4″ 3 (Ø35mm)
4
5 1.When the sink hole size is 35mm, please tighten the fixing nut (2)to the thread rod (1)and keep it horizontal with the counter. 3.Place washer(3) and metal plate(4) over mounting stud under sink. 4.Screw hexagonal lock nut (5) on to threaded rod (1) and tighten.
1
2 3 4 5
1.Use the triangle fastener(2) when the thickness of sink <5mm. 2.Place Triangle fastener(2) and washer(3) and metal plate(4) over mounting stud(1) under sink. Secure with mounting nut(5) .
5
COLD
2
Remove aerator (1) and turn faucet handles (2) to the full on position. Turn on cold water supplies and flush water lines for one minute. Important: This flushes away any debris that could cause damage to internal parts. Check all connections at arrow for leaks. Re-tighten if necessary, but do not overtighten.
Attach supply lines . Do not overtighten. Turn water back on.
2 1