Blunt Bird Dn -998 Infrared Thermometer User Manual

Blunt Bird Dn -998 Infrared Thermometer User Manual

BLUNT BIRD DN -998 Infrared Thermometer - LOGO

Introducing – Infrared Thermometer Check temperature maintaining safe distancing with the contactless thermometer.

BLUNT BIRD DN -998 Infrared Thermometer
MODEL: DN -998

BLUNT BIRD DN -998 Infrared Thermometer - ICONBeSafeMedikit
+91 9811609355
https://www.besafemedikit.com

Non- Contact
Infrared Thermometer

BLUNT BIRD DN -998 Infrared Thermometer - FIGURE 1

Product Life: 2 Year

Note: To ensure the correct use of this infrared thermometer, please read this manual carefully.

Product Description

This product is a non-contact medical infrared forehead thermometer for the professional measurement of human body temperature.

Fundamental

Anything above absolute zero radiates a certain amount of infrared ray energy, the infrared energy value radiated by different kinds of objects is different, but the infrared energy and wavelength can be used to judge the surface temperature value of the object. According to this principle, the temperature of the forehead can be accurately measured due to its constant temperature. And since the infrared intensity radiated from the forehead at the same temperature is different from that of other objects, such as water, there are at least two temperature models (body temperature and body temperature).

Product Features

  • Ergonomic design, simple & generous appearance.
  • Non-contact high precision, clean & sanitary measurement.
  • Excellent adaptability to environmental, change & can be used in complex environments.
  • One-click temperature switching, convenient & practical.
  • Double 32 groups of memory storage, one-click query, simple & practical.
  • Adjustment of temperature deviation to facilitate different user habits.
  • Automatic shutdown function, no automatic shutdown operation within 20 seconds.
  • Measuring method: Non-contact type
  • Effective Distance: 3cm – 15cm
  • Measuring Range: Human Model 32.0C – 42.9C (85.9F – 109.F)
  • Display: Trichrome backlight
  • Temperature unit: Celsius / Fahrenheit
  • Auto power off: Within 20 seconds.

Advice For The 1st Use

In order to obtain stable and reliable measurement data, when the temperature changes greatly, the infrared measuring instrument of the human body should be placed indoors for
15-20 minutes before use.
According to the skin color, thickness, and human body parts, the measured temperature will be different, which is normal. The more exposed the human body part is, the greater the impact of environmental temperature is Do not expose the product to the sun or touch the water One-minute interval after two consecutive measurements.

The normal temperature range at different measuring positions

Measuring temperature

NormMtempemtum°C

MnomMtemperaWWF

Anus36.63897.8-100.4
oral cavity35.5-37.595.9-99.5
Armpit34.7-37.394.4-99.1
Ear35.83896.4100.4

People’s body temperature changes at different times of the day, but is also affected by another external environment, such as age, character,skin color and thickness, etc.

The normal temperature range at different ages

AgeNormal temperature*CAt normal temperature
0-2yemsold36.4-38.097.5     100.4
340yeamold36.137.897.0100.0
11-65yearsold35.937.696.6      99.7
>65yearsold36.8-37.596.499.5

Technical Parameters

Measurement Methods

Non-Contact

Effective Distance3cm— 5cm
Measurement RangeHuman Body Model32.0″C —42. 91C (85.9°F —109.2°F
Object ModeOr .–   t100

(32’F-212°F)

Measurement PrecisionBody Temperature±0. 2*C10. 4°F
Object Temperature± 3.0°C/37.4°F
Resolution0.1°C/°F
Operating Conditions10t —40°C (50°F —104°F ) Rh‘.80% Non condensing
Storage Condition-25r-55t (-13°F-131°F) RH-90°A Non-condensing
PowerAAA Dry Battery
Power ConsumptionOff ModeClOuW
Working Mode-.530mW
Low Power InstructionsVoltageS.2.5V
MemoryDouble 32 Groups(Body Temperature, Object Temperature)
DisplayThree Colors Backlighting
Temperature UnitCelsius, Fahrenheit
Auto Power Shut Off20 Seconds
Dimension138x95x45mm
Net Weight86g
Meet StandardEN60601-1, EN 12470-5 , ASTM 1965-98

Product Illustration

1. Display1. Setting key
2. Handheld position2. Temperature unit
3. Infrared sensor3. Measuring button
4. Choice mode4. Battery Installation

BLUNT BIRD DN -998 Infrared Thermometer - FIGURE 2

LCD Indicator

Function definition

Icon

Detailed description

Battery level indicationBLUNT BIRD DN -998 Infrared Thermometer - ICON 3LightThe battery needs to be replaced due to insufficient power
TwinkleLow power, the battery needs to be replaced
DisappearEnough electricity, everything is normal
Measurement modeTemperaturebody temperature model
Object temperatureMaterial temperature model
Temperature unit°CCentigrade
°FFahrenheit degree
Temperatur valueBLUNT BIRD DN -998 Infrared Thermometer - ICON 4Measured temperature value
BLUNT BIRD DN -998 Infrared Thermometer - ICON 5OPEN

Button Functionality

BLUNT BIRD DN -998 Infrared Thermometer - FIGURE 6

No.

Name of Button

Description

1Temperature UnitSwitch between Celsius and Fahrenheit
2Memory ButtonView recently saved measurement data
3Body Tmemperartautruerte/
Object temperature
Temperature/temperature switch

Instructions

Temperature mode
Press the measurement key to start the machine, and the machine will self-check. Normally, all symbols will be displayed. Figure 1O-1) at this time, the machine will automatically measure the ambient temperature and display the ambient temperature (10-2). Make sure that the machine can be tested once in the temperature mode At this time, the measurement is completed and the results are displayed as shown In Figure 10.4). At this time, you can read the data according to the displayed results to determine whether the temperature is abnormal lithe machine is not operated within 15 seconds after measurement, it will automatically shut down

BLUNT BIRD DN -998 Infrared Thermometer - FIGURE 5

Note:

  1. Keep the head of the sensor clean and do not cover the front with anything
  2. In order to ensure the accuracy of measurement, it is recommended that when you enter a new environment where the temperature changes greatly, wait for ten minutes before measuring
  3. When the temperature of a very high or very low object is measured, wait for ten minutes before measuring the temperature

Sweat and stains on the forehead will affect the accuracy of measurement. Do not measure the body temperature within 30 minutes after eating, bathing, and exercise

Battery Replacement

When the battery symbol is displayed on the screen, please replace the battery, otherwise, the measurement result will be affected. Open the battery cover, take out the exhausted battery, put 2 AA dry batteries, please pay attention to the battery polarity, do not put reversely.

BLUNT BIRD DN -998 Infrared Thermometer - FIGURE 3

AS Notes:

  1. Please take out the battery when not used for a long time;
  2. Please do not throw exhausted batteries into the fire;
  3. Dispose of used batteries in accordance with local laws and regulations.

Usage Tips

  • Please read this instruction carefully before use;
  • The ambient temperature of this product is 10°C-40°C, and the best temperature is 25°C;
  • Please do not use this product in an environment higher than 40°C or lower than 0°C;
  • Please keep the product away from electrified objects to avoid electric shock; -Please do not use the product in an environment where the relative temperature is greater than 80%;
  • Please do not put this product too close to the electromagnetic range (such as radio, mobile phone, etc.);
  • Please do not expose the product to the sun or near the stove, and do not touch the water; -Please do not shoot down or drop this product. If it is damaged, please do not use it;
  • Hair on the forehead, sweat, a hat, or scarf can affect the accuracy of the measurements; -Please make sure the measuring distance is not greater than 15cm;
  • In order to obtain accurate, stable and reliable measurement data, when the room temperature changes greatly, the thermometer should be placed in the room for ten minutes after use;
  • When the forehead is sweating or other reason causes forehead temperature to be unable to reflect body temperature normally, can measure from earlobe hind; -When cleaning, please wipe the surface of the device with alcohol. In the event of a problem with the product, contact the distributor and do not attempt to repair it yoursiglim:Please keep this product out of the reach of children.

Q&A

Description

Solution

LCD display “LO” or HI”1. Wind, water vapor, sweat, Cosmetic may affect measurement results
2. Set the temperature deviation value
3. Large changes in ambient temperature
4. The measurement distance is too far
The measurement key is not responding1. Reinstall the battery

2. Whether the machine is under measurement

No display or error1. Reinstall the battery
No sound1. Make sure the sound switch is On
Shut down after measurement1. Check if the battery level is sufficient

Sign Description

Rated voltage BLUNT BIRD DN -998 Infrared Thermometer - ICON 6 3.0VBLUNT BIRD DN -998 Infrared Thermometer - ICON 7

Contact Us

Whether you’re interested in bulk purchase, or in manufacturing your own private label, you’re in the right place.
For Bulk/OEM/Retail Enquiries, Contact Us: BeSafeMedikit
Whatsapp: +91 9811609355,
Email: [email protected]
Website: https://www.besafemedikit.com

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals