Vaxcel P0375 Ellis 12 Light Pendant Instruction Manual

P0375 Ellis 12 Light Pendant

Product Information

The product is a light fixture that can accommodate a maximum of
60W type B bulb (not included). It comes with a mounting plate
unit, hardware package, and canopy kit for installation. The
fixture is adjustable in length from 23-3/4 to 68-3/4 inches by
using the threaded rods provided. It is designed for use in
accordance with local electrical codes for wiring and grounding
requirements. The fixture should be installed by a qualified
electrician to avoid the risk of electrical shock.

Product Usage Instructions

  1. Turn off the power at the fuse or circuit box.
  2. Attach the mounting plate unit (A) to the outlet box using two
    mounting screws (B).
  3. Adjust the arms of the fixture according to the picture on the
    package.
  4. Thread the fixture wire through the lower rod, middle rod, and
    upper rod respectively, securing each rod onto the fixture using
    the threaded pipe provided. Note: Use fewer rods if a shorter
    length is desired.
  5. Thread the fixture wire through the canopy kit, then secure the
    rod assembly to the set threaded pipe of the canopy kit.
  6. Pull out the source wires from the outlet box and make wire
    connections using wire connectors (C) as follows:
    • Connect the smooth-coated wire (marked) from the fixture to the
      black wire from the power source.
    • Connect the ribbed-coated wire (unmarked) from the fixture to
      the white wire from the power source.
    • Attach the fixture ground wire to the mounting strap unit (A)
      with the green ground screw, then connect it to the house ground
      wire with a wire connector (C).
  7. Carefully put the wires back into the outlet box.
  8. Attach the canopy kit to the mounting plate unit (A), and then
    secure it with two bolt nuts (D).
  9. Install 12 x 60W Max. candelabra base bulbs (not included). See
    relamping label at socket area or packaging for maximum wattage
    allowed.
  10. Angled mounting is recommended for a vaulted or angled
    ceiling.
  11. Turn on the power at the fuse or circuit box.

ASSEMBLY AND INSTALLATION INSTRUCTIONS

P0375
WARNING: TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.

NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.

2. READ AND SAVE THESE INSTRUCTIONS.

Outlet Box

Hardware Package (included):

House Ground Wire

Green Ground Screw

Mounting Plate Unit (A) Fixture Mounting Screw Mounting Screw (B)

Mounting Plate Unit (A) Mounting Screw (B)

Fixture Ground Wire Wire Connector (C)

Wire Connector (C)

Bolt Nut (D)

Max.60W Type B Bulb (not included)

Canopy Kit Bolt Nut (D) Threaded Pipe Upper Rod Threaded Pipe Middle Rod

Threaded Pipe

Installation Steps

Turn off the power at fuse or circuit box

Lower Rod

1. Attach the mounting plate unit (A) to the outlet box by using two mounting screws (B).
2. Adjust the arms of the fixture according to picture on the package.
3. Rod Connections: a. Thread the fixture wire from the fixture through the lower rod, then secure the lower rod onto fixture using the threaded pipe. b. Thread the fixture wire through the middle rod and then secure the middle rod onto the lower rod using the threaded pipe. c. Thread the fixture wire through the upper rod, then secure the upper rod onto the middle rod using the threaded pipe. Note: Length adjustable from 23-3/4″ to 68-3/4″. Use fewer rods if shorter length is desired.

Fixture Arm

4. Thread the fixture wire through the canopy kit, then secure the rod assembly to the set threaded pipe of the canopy kit.

220228

5. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows:

—Connect the smooth-coated wire (marked) from the fixture to the black wire from the power source.

—Connect the ribbed-coated wire (unmarked) from the fixture to the white wire from the power source.

—Attach the fixture ground wire to the mounting strap unit (A) with the green ground screw, then connect it to

the house ground wire with a wire connector (C).

Carefully put the wires back into the outlet box.

Fig. 1

6. Attach the canopy kit to the mounting plate unit (A), and then secure

it with two bolt nuts (D).

Support Brace

7. Install 12 x 60W Max. candelabra base bulbs (not included). See relamping label at socket area or packaging for maximum wattage allowed.
8. Angled mounting recommended for a vaulted or angled ceiling. (See Fig.1)

Outlet Box Canopy Coupling Kit

Turn on the power at fuse or circuit box

The following parts are available for re-order if damaged or missing.
Spare Parts List:

Mounting Hardware 6479MM (1 SET)

Mounting Plate Unit (A) Mounting Screw (B) Wire Connector (C) Bolt Nut (D)

12″ Rod 3323RD

6″ Rod 3322RD

3″ Rod 3321RD

A: 23-3/4″~68-3/4″
B: 25-1/4″
A