Calimet Cm9-631 Fire Access Box Instruction Manual

CM9-631 Fire Access Box

Product Information

The Fire Access Box is a device designed to provide access to
the fire department. It is compatible with various gate operators,
including Calimet Gate Operators and other brands. The box is ready
for a padlock (not supplied), which will be used by the fire
department to open the gate when access is required. It is
important to contact your local fire department to obtain
instructions on which padlock to use. While most fire departments
use Knoxbox, there may be some that use different suppliers.

For more information on Knoxbox and their commercial products,
you can visit their website at www.knoxbox.com/Products/Commercial-KnoxBoxes.

Product Usage Instructions

Calimet Gate Operators:

  1. Use 14-20 gauge AWG wire (not included) for the
    installation.
  2. Splice (join) the wires with the white and black wires of the
    gate operator.
  3. Locate the green terminal on the bottom right of the circuit
    board.
  4. Insert the white wire into the green terminal labeled
    “24V-COM”.
  5. Insert the black wire into the green terminal labeled “EXIT
    LOOP”.

Other Brand Gate Operators:

  1. Use 14-20 gauge AWG wire (not included) for the
    installation.
  2. Splice (join) the wires with the white and black wires of the
    gate operator.
  3. Connect the white wire to the “24V Common” terminal.
  4. Connect the black wire to the “Normal Open Relay”
    terminal.

It is important to ensure that the wires are securely connected
and that the gate operator is properly installed according to the
manufacturer’s instructions. Following these steps will enable the
Fire Access Box to function correctly with the respective gate
operator.

Fire Access Box Instruction Manual

CM9-631

Fire department access box ready for a padlock (not supplied). Your fire department will access this box which when opened, will cause the gate operator to open the gate. Contact your local fire department for instructions on which padlock to use. Most fire departments use knoxbox, but some may use different suppliers.
www.knoxbox.com/Products/Commercial-KnoxBoxes
Calimet Gate Operators
Use 14-20 gauge awg wire (not included) and splice (join) with the white and black wires.
Insert wires into green terminal normally located on the bottom right of the circuit board. White wire 24V-COM Black wire EXIT LOOP

Other Brand Gate Operators
Use 14-20 gauge awg wire (not included) and splice (join) with the white and black wires. White wire 24V Common Black wire Normal Open Relay