Installation instructions

Check the construction for vibration noise, make sure the cavity has the proper insulation. Prepare the wall or ceiling to fit in the speaker.

cerasonar-4062-Sub-Series-Invisible-Speaker-Fig1

Strip the wire by 10 mm. Connect the speaker cable to the speaker, be aware of the polarity.

cerasonar-4062-Sub-Series-Invisible-Speaker-Fig2

Insert the speaker, make sure there is no strain between the underlying insulation and speaker. Screw through all pre-drilled holes. The heads of the screws should penetrate about 1 mm into the panel material.

cerasonar-4062-Sub-Series-Invisible-Speaker-Fig3

Fill in plaster, we HIGHLY recommand using a flexible filler, e.g. Knauf Unifl ott or Ardex 828.

cerasonar-4062-Sub-Series-Invisible-Speaker-Fig4

Use mesh tape in the plastering process

cerasonar-4062-Sub-Series-Invisible-Speaker-Fig6

Up to 2mm of plaster can be applied, thus, Q3 and Q4 wall /ceiling quality levels are easily possible. ATTENTION: Before using the speaker, let the plaster dry off More information about the installation process is in our FAQ section.