S3910 Series Switches
S3910 Series Switches Software Upgrade Guide
Product Information:
The S3910 Series Switches Software Upgrade Guide provides
instructions for upgrading or downgrading the system software of
S3910-24TS and S3910-48TS switches. The upgrade is necessary to
optimize performance or add new features to the switch. The upgrade
can be done through the CLI interface, WEB interface, and
restarting the device. The version requires 512 MB of memory space
and 256 MB of Flash space.
Precautions:
- Pay attention to the prompt information output during the
operation. - If the upgrade fails, save the log information and contact FS
Network Technical Support. - Do not power off, reset the system, or insert or remove any
modules during the upgrade and downgrade process. - After the upgrade and downgrade are complete, run the show
version command to view the current version number of the device to
confirm the upgrade is successful.
Upgrade File:
To upgrade or downgrade to this version, use the following
upgrade file:
| Applicable Products | Upgrade File | File Description | File Size | MD5 Value |
|---|---|---|---|---|
| S3910-24TS | S3910_FSOS11.4(1)B70P1_install.bin | System installation package | 75475433 bytes | a0af188fa338201a3b0d58a654e3ffef |
| S3910-48TS | S3910_FSOS11.4(1)B70P1_install.bin | System installation package | 75475433 bytes | a0af188fa338201a3b0d58a654e3ffef |
Upgrade Steps:
4.1 Upgrade Under the Main Program
Follow the below configuration steps to set up the IP address of
the console port of the switch:
- Enter privileged mode by typing “S3910>enable”.
- Enter global configuration mode by typing “S3910#configure
terminal”. - Enter vlan 1 interface by typing “S3910(config)#interface vlan
1”. - Set management IP on vlan 1 interface by typing
“S3910(config-if)#ip address 192.168.1.200 255.255.255.0”. - Return to global configuration mode by typing
“S3910(config-if)#exit”.
Set the computer IP address, and confirm that the computer can
ping the switch, and the switch can also ping the computer. Use
software TFTP on local PC to specify the folder where the version
file is located and the IP address of the TFTP server. Once done,
upgrade through the CLI interface, WEB interface, and restart the
device to achieve.
S3910SS3e9r1i0esSSEwRIiEtcShSeWs SIToCfHtwEaSrSeOUFpTgWraAdReEGUuPiGdeRADE GUIDE
S3910 Series Switches Software Upgrade Guide
Models: S3910-24TS; S3910-48TS
www.fs.com
1
S3910 SERIES SWITCHES SOFTWARE UPGRADE GUIDE
Contents
1. Explanation…………………………………………………………………………………………………………………………………………………..1 2. Upgrade File………………………………………………………………………………………………………………………………………………… 1 3. TFTP Server Setup…………………………………………………………………………………………………………………………………………1 4. Upgrade Steps……………………………………………………………………………………………………………………………………………… 2
4.1 Upgrade Under the Main Program………………………………………………………………………………………………………………………………………….. 2 4.1.1 Network Topology………………………………………………………………………………………………………………………………………………………………….. 2 4.1.2 Configuration Steps………………………………………………………………………………………………………………………………………………………………… 2 4.1.3 Functional Verification……………………………………………………………………………………………………………………………………………………………..3 4.2 Upgrade in Uboot Mode…………………………………………………………………………………………………………………………………………………………. 4 4.2.1 Network Topology………………………………………………………………………………………………………………………………………………………………….. 4 4.2.2 Configuration Steps………………………………………………………………………………………………………………………………………………………………… 4 4.2.3 Functional Verification……………………………………………………………………………………………………………………………………………………………..6
www.fs.com
I
S3910 SERIES SWITCHES SOFTWARE UPGRADE GUIDE
1. Explanation
When new features are added or the original performance needs to be optimized and the current running version is lagging behind, the device needs to be upgraded. At this time, you need to load the higher version of the system software, upgrade through the CLI interface, WEB interface, and restart the device to achieve.
Precautions
This version requires: 512 MB of memory space and 256 MB of Flash space. In the process of upgrading and downgrading, please pay attention to the prompt information output during the operation. If it fails,
please save the log information and contact FS Network Technical Support. During the upgrade and downgrade process, there will be a prompt message not allowing restart. Once such a prompt message
appears, please do not power off, do not reset the system, and do not insert or remove any modules. After the upgrade and downgrade are complete, run the show version command to view the current version number of the device
to confirm the upgrade is successful.
2. Upgrade File
To upgrade the device to this version or downgrade to this version, you need to use the following upgrade file.
Applicable Products
S3910-24TS S3910-48TS
Upgrade File File Description
File Size MD5 Value
Upgrade File
S3910_FSOS11.4(1)B70P1_install.bin System installation package 75475433 bytes
a0af188fa338201a3b0d58a654e3ffef
3. TFTP Server Setup
Use software TFTP on local PC Specify the folder where the version file is located and the IP address of the TFTP server
www.fs.com
1
S3910 SERIES SWITCHES SOFTWARE UPGRADE GUIDE
4. Upgrade Steps
4.1 Upgrade Under the Main Program
4.1.1 Network Topology
4.1.2 Configuration Steps
Set the IP address of the console port of the switch
S3910>enable
——->Enter privileged mode
S3910#configure terminal
——->Enter global configuration mode
S3910(config)#interface vlan 1
——->Enter vlan 1 interface
S3910(config-if)#ip address 192.168.1.200 255.255.255.0
——->Set management ip on vlan 1 interface
S3910(config-if)#exit
——->Return to global configuration mode
Set the computer IP address, and confirm that the computer can ping the switch, and the switch can also ping the computer
C:UsersFS>ping 192.168.1.200
Ping 192.168.1.200 with 32 bytes of data: Reply from 192.168.1.200: Byte=32 Time=3ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64
Ping statistics of 192.168.1.200: Packet: Sent = 4, Received = 4, Lost = 0 (0% lost),
Estimated time of round trip (in milliseconds): Shortest = 2ms, longest = 3ms, average = 2ms
S3910#ping 192.168.1.100 Sending 5, 100-byte ICMP Echoes to 192.168.1.100, timeout is 2 seconds:
< press Ctrl+C to break > !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 1/1/2 ms. NOTE: The firewall function of the computer must be turned off, and the anti-virus software must be exited, otherwise the upgrade may not succeed Put the tftp software (tftp software can be downloaded from the Internet) and the new software version into the same directory. Start the tftp tool and execute the following commands on the switch, the device will be automatically upgraded: S3910#upgrade download tftp://192.168.1.100/S3910_FSOS11.4(1)B70P1_install.bin Upgrade the device must be auto-reset after finish, are you sure upgrading now?[Y/N]y The following prompt indicates that the upgrade was successful:
www.fs.com
2
S3910 SERIES SWITCHES SOFTWARE UPGRADE GUIDE
*Jul 13 16:38:59: %UPGRADE-6-INFO: *Jul 13 16:38:59: %UPGRADE-6-INFO: [Slot 0]:Upgrade processing is 10% *Jul 13 16:38:59: %UPGRADE-6-INFO: *Jul 13 16:39:04: %UPGRADE-6-INFO: [Slot 0]:Upgrade processing is 20% *Jul 13 16:39:04: %UPGRADE-6-INFO: *Jul 13 16:39:07: %UPGRADE-6-INFO: [Slot 0]:Upgrade processing is 30% *Jul 13 16:39:07: %UPGRADE-6-INFO: *Jul 13 16:39:08: %UPGRADE-6-INFO: [Slot 0]:Upgrade processing is 40% *Jul 13 16:39:08: %UPGRADE-6-INFO: *Jul 13 16:40:21: %UPGRADE-6-INFO: [Slot 0]:Upgrade processing is 50% *Jul 13 16:40:21: %UPGRADE-6-INFO:
Upgrade info [OK]
Rootfs version[1.0.0.eefb500f->1.0.0.3e33691f]
*Jul 13 16:40:21: %UPGRADE-6-INFO: [Slot 0]:Upgrade processing is 80%
*Jul 13 16:40:21: %UPGRADE-6-INFO:
Reload system to take effect!
*Jul 13 16:40:21: %UPGRADE-6-INFO: [Slot 0]:
*Jul 13 16:40:21: %UPGRADE-6-INFO: Upgrade info [OK]
*Jul 13 16:40:21: %UPGRADE-6-INFO:
Rootfs version[1.0.0.eefb500f->1.0.0.3e33691f]
*Jul 13 16:40:21: %UPGRADE-6-INFO:
*Jul 13 16:40:21: %UPGRADE-6-INFO: [Slot 0]:Reload system to take effect!
*Jul 13 16:40:21: %UPGRADE-6-INFO:
*Jul 13 16:40:21: %UPGRADE-6-INFO: [Slot 0]:Upgrade processing is 100%
*Jul 13 16:40:21: %UPGRADE-6-INFO: System is reloading due to upgrade.
*Jul 13 16:40:23: %UPGRADE-6-INFO: Auto-sync box config synchronization, Please wait for a moment….
*Jul 13 16:40:23: %UPGRADE-6-INFO: [Slot 0]
*Jul 13 16:40:23: %UPGRADE-6-INFO:
status:
SUCCESS
*Jul 13 16:40:23: %DP-3-RESET_DEV: Reset device 1 due to upgrade package.
*Jul 13 16:40:23: %DP-3-MACHINE_RESTART: MACHINE_RESTART.
SysRq : Resettin
Restart the switch
S3910#reload
——–>Restart the switch to take effect
Reload system?(Y/N) y
After restart, confirm whether the switch is successfully upgraded
4.1.3 Functional Verification
Confirm whether the version is the upgraded version by show version
www.fs.com
3
S3910 SERIES SWITCHES SOFTWARE UPGRADE GUIDE
4.2 Upgrade in Uboot Mode
4.2.1 Network Topology
4.2.2 Configuration Steps
Restart the device When the Ctrl+C prompt appears, press the CTRL and C keys simultaneously on the keyboard to enter the bootloader menu Boot 1.2.28-0c4a1bf (Feb 09 2017 – 17:14:53)
I2C: ready DRAM: 508 MiB NAND: (ONFI), chipsize 512 MiB In: serial Out: serial Err: serial Unlocking L2 Cache …Done arm_clk=1000MHz, axi_clk=400MHz, apb_clk=100MHz, arm_periph_clk=500MHz SETMAC: Setmac operation was performed at 2020-02-28 15:24:58 (version: 11.0) Press Ctrl+C to enter Boot Menu Net: eth-0 Entering simple UI….
====== BootLoader Menu(“Ctrl+Z” to upper level) ====== TOP menu items.
************************************************ 0. Tftp utilities. 1. XModem utilities. 2. Run main. 3. SetMac utilities. 4. Scattered utilities. 5. Set Module Serial
************************************************ After entering the bootloader menu, click the red reminder below to enter the address configuration menu ====== BootLoader Menu(“Ctrl+Z” to upper level) ======
TOP menu items. ************************************************
0. Tftp utilities. 1. XModem utilities.
www.fs.com
4
S3910 SERIES SWITCHES SOFTWARE UPGRADE GUIDE
2. Run main. 3. SetMac utilities. 4. Scattered utilities. 5. Set Module Serial ************************************************ Press a key to run the command: 0
====== BootLoader Menu(“Ctrl+Z” to upper level) ====== Tftp utilities.
************************************************ 0. Upgrade bootloader. 1. Upgrade kernel and rootfs by install package. 2. Down to memory and jump to run.
************************************************ Press a key to run the command: 1
Under the menu, follow the prompts to enter the switch device address, execute the pc address, and the file name to be upgraded
Plz enter the Local IP:[]: 192.168.1.200
———Switch address
Plz enter the Remote IP:[]: 192.168.1.100
———PC address
Plz enter the Filename:[]: S3910_FSOS11.4(1)B42_install.bin
——— Upgrade bin file
Follow the prompts to select Y to continue to the next step
Determined to upgrade? [Y/N]: Y
Upgrading, keep power on and wait please …
Upgrading boot …
After successful upgrade, automatically return to the bootloader menu interface, press ctrl+z to exit the menu item to restart ====== BootLoader Menu(“Ctrl+Z” to upper level) ======
Tftp utilities. ************************************************
0. Upgrade bootloader. 1. Upgrade kernel and rootfs by install package. 2. Down to memory and jump to run. ************************************************ Press a key to run the command:
====== BootLoader Menu(“Ctrl+Z” to upper level) ====== TOP menu items.
************************************************ 0. Tftp utilities. 1. XModem utilities. 2. Run main. 3. SetMac utilities. 4. Scattered utilities. 5. Set Module Serial
www.fs.com
5
S3910 SERIES SWITCHES SOFTWARE UPGRADE GUIDE
************************************************ Press a key to run the command: 2 Unmounting UBIFS volume kernel!
4.2.3 Functional Verification
Confirm whether the version is the upgraded version by show version
S3910#show version
System description
: FS 10G Ethernet Switch(S3910-24T4S) By FS Networks
System start time
: 2020-07-13 16:38:39
System uptime
: 0:00:04:31
System hardware version : 1.31
System software version : S3910_FSOS 11.4(1)B70P1
System patch number
: NA
System serial number : G1PT3MT001131
System boot version
: 1.2.28
Module information:
Slot 0 : S3910-24T4S
Hardware version : 1.31
Boot version
: 1.2
Software version : S3910_FSOS 11.4(1)B70P1
Serial number
: G1PT3MT001131
www.fs.com
6















