IO Module Smart Zigbee Input Output
Product Information
The IO Module is a preventive, informing device that is designed
to provide warnings and protection. It is not a guarantee or
insurance against property damage, theft, injury, or any similar
situations. Please note that the manufacturer, frient, cannot be
held responsible in case any of these situations occur.
The IO Module can be connected to various wired devices such as
doorbells, window blinds, wired security devices, heat pumps, and
more. The connection process for these devices is the same, using
the different inputs and outputs provided.
- Inputs:
- IN1: Inputs with internal Pull Up. Must be shorted to IO Module
GND for signal. - IN2: IO Module GND
- IN3: NC2 Normally Closed for Relay Output 2
- IN4: COM2 Common for Relay Output 2
- NO2: Normally Open for Relay Output 2
- NC1: Normally Closed for Relay Output 1
- COM1: Common for Relay Output 1
- NO1: Normally Open for Relay Output 1
- IN1: Inputs with internal Pull Up. Must be shorted to IO Module
- Output:
- Max Load: 1A 1E4
- Voltage Range: 5 – 28 V d.c.
Power Supply:
- Use either 5-28 V or USB PWR as the power supply.
- If both power sources are connected, 5-28V is the primary power
supply. - If 5-28 V is disconnected, USB PWR acts as a fallback power
source.
Reset:
- Resetting is required to connect the IO Module to another
gateway or to perform a factory reset to resolve abnormal
behavior. - Follow the steps below to reset the IO Module:
- Connect the IO Module to a power outlet.
- Press and hold the reset button with a pen.
- While holding the button down, the yellow LED will flash once,
then twice in a row, and finally numerous times in a row. - Release the button while the LED is flashing numerous times in
a row. - After releasing the button, the LED will show one long flash,
indicating that the reset is completed.
Modes:
- SEARCHING GATEWAY MODE: The yellow LED flashes
while the IO Module is searching for a Zigbee network to join.
Product Usage Instructions
Getting started:
- Connect and power up the IO Module.
- The IO Module will start searching for a Zigbee network to
join. This process can take up to 15 minutes, during which the
yellow LED will flash. - Ensure that the Zigbee network is open for joining devices and
will accept the IO Module. - Once the LED stops flashing, it indicates that the IO Module
has successfully joined the Zigbee network. - If the scanning process times out, perform a short press on the
reset button to restart it.
Disposal:
Dispose of the product properly at the end of its life. This is
electronic waste that should be recycled.
FCC Statement:
Changes or modifications to the equipment not expressly approved
by the party responsible for compliance could void the user’s
authority to operate the equipment. Please note that this equipment
has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver. - Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for
help.
eng IO Module
INSTALLATION MANUAL
Version 1.0
Product description With the IO Module, you can connect wired devices to a Zigbee network. Providing four inputs and two outputs, the IO Module works as a bridge between wired devices and a control system over Zigbee networks. Disclaimers CAUTION: · Choking hazard! Keep away from children.
Contains small parts. · Please follow the guidelines thoroughly. The
IO Module is a preventive, informing device, not a guarantee or insurance that sufficient warning or protection will be provided, or that no property damage, theft, injury, or any similar situation will take place. frient cannot be held responsible in case any of the above-mentioned situations occur.
Precautions · WARNING: For safety reasons, always
disconnect power from the IO module, before connecting wires to inputs and outputs. · Do not remove the product label as it contains important information. · Do not open the IO Module. · Do not paint the device.
Placement Connect the IO Module to a device that is located at a temperature between 0-50°C.
Connecting to wired device You can connect the IO Module to different wired devices: doorbells, window blinds, wired security devices, heat pumps and more. The connection of the different devices follows the same principle, using the different inputs and outputs: a.
IN4 IN3I IN2 IN1
NC 2 COM 2 NO 2 NC 1 COM 1 NO 1
Inputs are internal pull up
Output max load 1A 1E4
5 – 28 V d.c.
T50
USB PWR
RST LED
IN1 Inputs with internal Pull Up. Must be
IN2 shorted to IO Module GND for signal
IN3 IO Module GND
IN4 NC2 Normally Closed for Relay Output 2 COM2 Common for Relay Output 2 NO2 Normally Open for Relay Output 2 NC1 Normally Closed for Relay Output 1 COM1 Common for Relay Output 1 NO1 Normally Open for Relay Output 1
5-28 V d.c.
Power Supply NOTE: Use “5-28 V” or “USB PWR”. If both are connected “5-28V” is the primary Power Supply.
USB PWR
Power Supply NOTE: USB PWR is then used as fall back in case “5-28 V” is disconnected.
RST Reset
LED User Feedback
Getting started
1. When the device is connected and powered up, the IO Module will start searching (up to 15 minutes) for a Zigbee network to join. While the IO Module is searching for a Zigbee network to join, the yellow LED flashes.
2. Make sure that the Zigbee network is open for joining devices and will accept the IO Module.
3. When the LED stops flashing, the device has successfully joined the Zigbee network.
4. If the scanning has timed out, a short press on the reset button will restart it.
b.
Resetting Resetting is needed if you want to connect your IO Module to another gateway or if you need to perform a factory reset to avoid abnormal behavior. STEPS FOR RESETTING 1. Connect the IO Module to a power outlet.
2. Press and hold the reset button with a pen (see Illustration b).
3. While you are holding the button down, the yellow LED first flashes once, then two times in a row, and finally numerous times in a row.
c.
4. Release the button while the LED is flashing numerous times in a row.
5. After you release the button, the LED shows one long flash, and the reset is completed.
Modes SEARCHING GATEWAY MODE The yellow LED flashes.
Fault finding · In case of a bad or weak wireless signal,
change the location of the IO Module. Otherwise, you can relocate your gateway or strengthen the signal with a range extender. · If the search for a gateway has timed out, a short press on the button will restart it.
Disposal Dispose the product properly at the end of its live. This is electronic waste which should be recycled.
FCC statement Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/ TV technician for help.
This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
IC statement
English
This device contains licence-exempt
transmitter(s)/receiver(s)
that
comply
with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two
conditions:
1. This device may not cause interference.
2. This device must accept any interference,
including interference that may cause
undesired operation of the device. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.
Français
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Cet équipement est conforme aux limites d’exposition aux radiations IC CNR-102 établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps.
ISED statement
Innovation, Science and Economic Development Canada ICES-003 Compliance Label: CAN ICES-3 (B)/NMB-3(B).
CE certification The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product and, in particular, its compliance with the harmonized standards and specifications.
IN ACCORDANCE WITH THE DIRECTIVES · Radio Equipment Directive (RED)
2014/53/EU · RoHS Directive 2015/863/EU amending
2011/65/EU · REACH 1907/2006/EU + 2016/1688
Other certifications Zigbee 3.0 certified
All rights reserved. frient assumes no responsibility for any errors, which may appear in this manual. Furthermore, frient reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and frient does not make any commitment to update the information contained herein. All the trademarks listed herein are owned by their respective owners.
Distributed by frient A/S Tangen 6 8200 Aarhus Denmark
Copyright © frient A/S