DW24T3IXV Built In Dishwasher
Product Information:
– Product Dimensions: 33 7/8-35 7/8 inches (860-910 mm) wide, 29
3/4 inches (757 mm) high. – Cutout Dimensions: 23 9/16 inches (598
mm) wide, 22 1/2 inches (570 mm) high. – Water Drain: Minimum 3 1/8
inches (80 mm), maximum 5 1/8 inches (130 mm). – Power: Electrical
receptacle should be installed according to the provided drawing. –
Water Inlet: Use a 3/8 water inlet hose and a 3/4 metal adapter
with a length of 60 inches (1524 mm). – Flush Installation Depth: A
minimum inset depth of 22 1/2 inches (570 mm) is required. –
Installation Requirements: Follow local codes and ordinances for
drain requirements. Install a waste line with an air gap or a high
drain loop of at least 30 inches (762 mm) to prevent backflow.
Drain hose length is 74 inches (1880 mm), and it should be
connected at a minimum of 20 inches (508 mm) from the floor.
Product Usage Instructions:
1. Measure and ensure that the cutout dimensions in your
installation area match the provided dimensions of the product. 2.
Properly ground the electrical receptacle according to the provided
drawing. 3. Connect the water mains to the water inlet valve using
a 3/8 water inlet hose and a 3/4 metal adapter with a length of 60
inches (1524 mm). 4. Place the product into the cutout, ensuring it
fits securely. 5. If you prefer a flush installation, make sure to
have a minimum inset depth of 22 1/2 inches (570 mm). 6. Follow
local codes and ordinances for drain requirements. Install a waste
line with an air gap or a high drain loop of at least 30 inches
(762 mm) to prevent backflow. 7. Connect the drain hose provided
with the unit at a minimum of 20 inches (508 mm) from the floor. 8.
Ensure all connections are properly placed on either side of the
cutout. 9. After installation, refer to the user manual for further
instructions on operating and maintaining the product.
33 7/8″-35 7/8″ 860-910
3 15/16″ (100) + 2″ (50) feet adjustment
29 3/4″ 757
PRODUCT DIMENSIONS
SIDE VIEW
22 1/2″ 570
1 3/16″- 3 1/8″ (30 -80)*
FRONT VIEW
23 9/16″ 598
4 1/8″ (105)*
2″ (50)
* including the door
47 1/4″ 1200
CUTOUT DIMENSIONS
SIDE VIEW
FRONT VIEW
TOP VIEW
23 9/16″ 598
22 1/2″ 570
WATER DRAIN
POWER
WATER INLET
min 3 1/8″ (80) max 5 1/8″ (130)
Drain hose and toe kick are provided with the unit
TOP VIEW
34″-36″ 864-914
24″ (610)*
or 23 5/8″ (600)**
25″ (635)***
* with vertical side trims installed ** without vertical side trims
ELECTRICAL & WATER CONNECTION
A properly-grounded,
TOP VIEW
horizontally-mounted
E electrical receptacle
EW
EW
should be installed
according to this drawing.
To connect the water
FRONT VIEW
mains to the water inlet
W valve thread, use a 3/8″ water inlet hose and 3/4″
EW
EW
metal adapter with a
length of 60″ (1524) (not
supplied).
Connections placement must be located on either side of the cutout.
*** For a flush installation, a minimum inset depth of 22 1/2″ (570) is required.
INSTALLATION REQUIREMENTS
2″
Follow local codes & ordinances for drain
50
requirements. Install a waste line with an air gap
(not supplied) or, alternatively, at least 30″ (762)
high drain loop to prevent backflow. Drain hose is
74″ (1880) long. Drain hose must be connected
at minimum 20″ (508) from the floor.
3 15/16″ 100
Dimensions in parentheses are millimeters unless otherwise specified.