Pentair Chlorplus Protect 10 Water Filtration System Instruction Manual

Chlorplus Protect 10 Water Filtration System

Product Information

The ChlorPlus Protect 10 Water Filtration System is designed to
reduce the concentration of specific substances in water. It has
been tested according to NSF/ANSI Standard 53 and meets the
requirements for reducing Perfluorooctanoic Acid (PFOA) and
Perfluorooctane Sulfonate (PFOS) to a concentration less than or
equal to the permissible limit.

The system has an average reduction of 98.20% for the listed
substances. It operates at a flow rate of 1 gallon per minute (3.79
liters per minute) and has a capacity of 1,000 gallons (3,785.41
liters) or 12 months.

Product Usage Instructions

Installation

  1. Ensure that the water supply is turned off before starting the
    installation.
  2. Connect the system to the water supply using the provided
    inlet/outlet connections. For brass fittings, tighten the nut
    snugly about 1/2-turn with a wrench.
  3. Turn on the water supply and check for any leaks. If leaks
    persist, turn off the water supply and contact Pentair Technical
    Support at 1.800.279.9404.

Troubleshooting Leaks

If there are leaks between the cap and bottom of the filter
housing:

  1. Turn off the water supply and press the red pressure-relief
    button.
  2. Remove the bottom of the housing.
  3. Clean the O-ring and O-ring groove located beneath the threads
    of the housing.
  4. Lubricate the O-ring with silicone lubricant and place it
    securely into the groove.
  5. Screw the bottom of the filter housing onto the cap and
    hand-tighten. Do not overtighten.

If there are other leaks on the system, turn off the water
supply and contact Pentair Technical Support at 1.800.279.9404.

Replacement Parts

For replacement parts, contact your nearest Pentair dealer or
call 1.800.279.9404. The following replacement parts are
available:

  1. 151039 – Pressure-relief button kit
  2. 154101 – Black cap (W/PR 3/4)
  3. 151120 – O-ring, cap
  4. 153019 – Blue housing
  5. 655226-43 – ChlorPlus Protect 10 cartridge
  6. 151011 – UB-1KIT mounting bracket kit
  7. 150295-06 – SW-2 housing wrench

Precautions

  • Do not use the system with water that is microbiologically
    unsafe or of unknown quality without adequate disinfection before
    or after the system.
  • Protect the filter against freezing, as it can cause cracking
    and water leakage.
  • Ensure that the rubber O-ring is properly seated in the groove
    below the threads of the housing to prevent water leaks.
  • Replace the bottom of all plastic housings every 10 years for
    opaque to prevent costly repairs or water damage. Date the bottom
    of any new or replacement housing to indicate the next recommended
    replacement date.

For more information on product warranties, visit pentair.com/assets/residential-filtration-warranty.

For any further assistance, please contact Pentair Customer
Service at 800.279.9404 or email [email protected].

PERFORMANCE DATA SHEET This system has been tested according to NSF/ANSI Standard 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water exiting the system, as specified in NSF/ANSI Standard 53. Testing was performed under standard laboratory conditions; actual performance may vary.

Substance

Influent Challenge Max. Permissible Product Reduction

Concentration

Water Concentration Requirements

Standard 53

Perfluorooctanoic Acid (PFOA) and Perfluorooctane Sulfonate (PFOS)

0.0015 mg/L ± 10%

0.00007 mg/L

n/a

Flow Rate = 1 gpm (3.79 L/min); Capacity = 1,000 gallons (3,785.41 L) or 12 months

Average Reduction 98.20%

TROUBLESHOOTING
Leaks: Between Cap and Bottom of Filter Housing: 1. Turn off water supply and press the red pressure-relief button. Remove bottom of the
housing. 2. Clean O-ring and O-ring groove (located directly beneath threads of housing). Lubricate
the O-ring with silicone lubricant and replace securely into groove. Screw bottom of filter housing onto cap and hand-tighten. Do Not Overtighten.
On Inlet/Outlet Connections: 1. Turn off water supply. For brass fittings, tighten nut snugly about 1/2-turn with a wrench. 2. Turn on water supply. If leaks persist, or if there are other leaks on the system, turn off
water supply. Call Pentair Technical Support at 1.800.279.9404.

REPLACEMENT PARTS

1. 151039 2. 154101

Pressure-relief button kit Black cap (W/PR 3/4″)

3. 151120 4. 153019

O-ring, cap Blue housing

5. 655226-43 ChlorPlus Protect 10 cartridge

6. 151011

UB-1KIT mounting bracket kit

7. 150295-06 SW-2 housing wrench

For replacement parts, contact your nearest Pentair dealer or call 1.800.279.9404.

1

2

3 4

5

6

7 5

For Pentair product warranties visit: pentair.com/assets/residential-filtration-warranty

13845 Bishops Dr. | Suite 200 | Brookfield, WI 53005 | United States P: 262.238.4400 | Customer Service: 800.279.9404 [email protected] | pentair.com
All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners. ©2022 Pentair. All Rights Reserved.

150743 Rev A NO22

CHLORPLUSTM PROTECT 10 WATER FILTRATION SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS

OPERATING SPECIFICATIONS

Pressure Range:

30­125 psi (2.1­8.6 bar)

Flow Rate:

1 gpm (3.78 Lpm)

Capacity:

1,000 gallons (3,785 L)

Temperature Range:

40­100°F (4.4­37.7°C)

PARTS INCLUDED
· 10″ filter housing · ChlorPlus Protect 10 cartridge · Filter housing cap · O-ring

· Mounting bracket kit
· Screw kit · Housing wrench

TOOLS AND MATERIALS REQUIRED (not included)

· Appropriate fittings and pipe to install filter · Phillips head screwdriver

· Plumber’s tape

· Adjustable wrenches (2)

· File

· Pipe cutters or hacksaw

· Pencil

PRECAUTIONS
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
CAUTION: Filter must be protected against freezing, which can cause cracking of the filter and water leakage.
CAUTION: The rubber O-ring provides the watertight seal between the cap and the bottom of the housing. It is important that the O-ring be properly seated in the groove below the threads of the housing or a water leak could occur.
CAUTION: Because of the product’s limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the bottom of all plastic housings be replaced every 10 years for opaque. If the bottom of your housing has been in use for longer than this period, it should be replaced immediately. Date the bottom of any new or replacement housing to indicate the next recommended replacement date.

The ChlorPlus Protect 10 system is certified by IAPMO R&T against NSF/ANSI 53 for the reduction of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS).

PENTAIR.COM

NOTE:
· For cold water use only · Do not install where system will be exposed to direct sunlight. · Make certain that installation complies with all state and local laws and regulations. · The contaminants or other substances removed or reduced by the selected filter
cartridge are not necessarily in your water. Ask your local water municipality for a copy of their water analysis, or have your water tested by a reputable water testing lab. · After prolonged periods of non-use (such as during a vacation) it is recommended that the system be flushed thoroughly. Let water run for five (5) to six (6) minutes before using. · The filter cartridge used with this system has a limited service life. If there are any changes in taste, odor, color, and/or flow of the filtered water, please replace the filter cartridge. · Spent adsorption media will not be regenerated and used.

INSTALLATION
NOTE: · Please read all instructions, specifications, and precautions before installing and using
this filter. · For installation on standard 1/2″ or 3/4″ main water line (galvanized, copper or plastic pipe). · Only use plumber’s tape for fitting housing connections. · Install filter cartridge in filter housing according to the filter cartridge replacement
instructions on p.4 before proceeding with installation. See Filter Cartridge Selection Guide on p.5 to determine the best filter cartridge for your filtration needs. · Install filter cartridge after water meter or pressure tank. · Numbered diagrams correspond with numbered steps.

1. [A] Turn off cold water supply, and open nearest faucet [B] to release pressure in pipes before starting installation.

[C] Apply about 6″ of plumber’s tape in

clockwise direction to pipe threads of

1

B

each adapter.

2. [D] If mounting bracket is to be used, use bracket as a template to mark screw locations on wall. Insert mounting screws into wall.

[E] Leave a space the thickness of

A

C

a nickel (2mm) between the head of

the screw and the wall to slip bracket

onto screws. Then place bracket over

the cap and align with inlet and outlet

ports.

2

NOTE: Allow 1 1/2″ clearance below housing to enable filter cartridge changes.

D

E

3. [F] Assemble all fittings. Start adapters into cap by hand. Use a wrench to tighten firmly. DO NOT OVERTIGHTEN. About one thread should remain visible.

[G] Remove compression nuts from fittings.

NOTE: If using mounting bracket, be

sure to insert fittings through bracket

before threading into filter cap.

3

F

G

INSTALLATION CONTINUED

4. [H] Measure length across assembled

fittings and subtract 1″ for 3/4″ pipe or

1 1/2″ for 1/2″ pipe. Mark section of pipe to be removed.

4

H

NOTE: Approximately 6″ will be

removed for 3/4″ pipe and 5 1/4″ for 1/2″ pipe.

I

[I] Using a pipe cutter or hacksaw, cut pipe and remove marked section. File or sand sharp edges on remaining pipe.

5. [J] Slip brass compression nut and brass ferrule [K] onto each end of 3/4″ pipe.

[L] If installing on 1/2″ pipe, substitute rubber ferrule for brass ferrule.

6. [M] Align filter assembly with ends

5

of pipe, making certain cap opening

marked “IN” is facing your incoming

water supply [N]. It will be necessary to spread ends of pipe apart to install filter assembly. Using two (2) adjustable wrenches, hold inlet adapter securely with one wrench and tighten with second wrench. Repeat process for outlet adapter.

NOTE: If using mounting bracket, be

6

sure to slip bracket over screws in wall

(see step 2).

K

J

L

M

7. [O] Slowly turn on water supply to allow

filter to fill with water. [P] Depress red

pressure-relief button on top of cap to

N

release trapped air. Check for leaks.

[Q] Open nearest faucet and flush filter

cartridge for five (5) minutes.

CAUTION: If water pipes are used to

ground electrical systems, appliances,

7

P

or phones, be sure to install a jumper

wire. Contact a qualified electrician

with any questions about your home’s electrical system.

Q

O

2

3

FILTER CARTRIDGE REPLACEMENT

WARNING: Use safety glasses when

handling household bleach to prevent

bodily injury. Follow bleach manufacturer’s

A

2

instructions when handling bleach.

A. [1] Turn off cold water supply, open nearest faucet.

NOTE: This will shut off all water flow

within the household. Fill a bucket with

water to clean housing after it has been

1

removed.

3

[2] Depress red pressure-relief button to release pressure. [3] Remove bottom of the housing by turning clockwise.

B. [4] Locate and remove the large O-ring, wipe clean of lubricant and set aside. [5] Discard used cartridge. Rinse out bottom of the housing and fill 1/3 full with water. Add two (2) tablespoons of bleach and scrub cap and bottom of the housing with non-abrasive sponge or cloth. Rinse thoroughly.

B
4 5

Lubricate the O-ring [4] with clean silicone grease. Insert the O-ring back into groove and smooth into place with finger.

NOTE: This step is important to ensure

proper housing seal. Make sure the

8

O-ring is seated level in the groove.

C

Insert new cartridge [5] over standpipe

in bottom of the housing.

C. [6] Screw bottom of the housing onto the cap and hand-tighten. DO NOT OVERTIGHTEN. Make certain cap standpipe slips into cartridge.
[7] Slowly open the cold water supply 1/4-turn counterclockwise to allow the filter to fill with water.

7 6

[8] Depress red pressure-relief button (if present) to release trapped air. Flush cartridge for five (5) minutes before use. Flush again for 10 minutes before using water.

Check for leaks before leaving installation.

MAINTENANCE: The filter must be maintained according to manufacturer’s instructions, including replacement of filter cartridge. Contact your nearest Pentair dealer for replacement cartridges or call 1.800.279.9404 for help locating a Pentair dealer.

PENTAIR CHLORPLUS PROTECT 10 SYSTEM · INSTALLATION AND OPERATION INSTRUCTIONS 4

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals