AF-3 Special Effects Fan
AF-3/AF-3X/AF-3S Special Effects Fan User Manual – English
User Manual
Please read all the user manual before operating the machine,
and place the manual where the user can refer to it at all time.
The manual includes how to install and operate the machine under
safe condition and explain all the labels printed on the machine.
If you encounter any problem, contact your local Antari dealer for
assistant immediately.
Safety Information
- Danger: If the danger is not avoided, it will
cause death or serious injury. - Warning: If the warning is not heeded, it can
cause death or serious injury. - Caution: If the precaution is not taken, it
may cause minor or moderate injury.
Danger
- Must connect the machine to the correct rated voltage or it
might lead to an electrical shock or a burn and may cause serious
consequences. - Must connect the machine to a protected circuit and ensure it
is properly grounded to avoid the risk of electrocution. For
grounding instruction, please refer to Appendix I on page 17. - Do not operate the machine with a bundled power cord, it could
lead to a fire hazard. - Do not use the fan in an environment full of flammable gas,
susceptible to water or powder. Keep away from any fire and heat
sources. - When operating the machine, do not point at people, animals, or
fire.
Warning
- Please operate the machine on a flat, level hard and well
ventilated surface area, reserve at least 50cm space around the
machine and make sure there is no flammable gas or material
nearby. - Do not disassemble, repair or modify the machine, it may cause
damages, malfunction, risk of electrical shock or result in
fire. - The machine can only be operated by adults or professionals, is
not intended for use by person with reduced
Caution
- Keep the machine dry at all time. The machine is not
waterproof, do not expose the machine to water, rain, or moisture
environment. - Please make sure the power outlet is not damaged or loose
before plug in the power cord. - If the power cord is damaged, it must be replaced by Antari or
its local dealers, otherwise the warranty will be void. - The machine is for indoor use only.
- Do not operate the machine in any area with unstable
voltage. - If you experience strange sound or malfunction, turn off the
power and unplug the power cord immediately and contact your local
Antari dealer for assistant. - Do not contact any moving part.
- Only use accessories recommended or sold by Antari.
- Please make sure the power is off when not using the machine
and unplug the power cord if not intend to use for a long period of
time. - To disconnect, turn all controls to the off position, then
remove plug from outlet. - Do not unplug by pulling on cord. To unplug, grasp the plug,
not the cord. - Unplug from outlet before servicing or cleaning.
- Ensure that curtain, clothing, cables or other items cannot be
suck into the fan. - Do not operate the machine with a damaged cord or plug, or
after the machine malfunctions or is dropped or damaged in any
manner. Return machine to the nearest authorized service facility
for examination, repair, or electrical or mechanical
adjustment. - After a period of operation, abnormal noise and uneven air
volume may appear because of dust blocking airflow. It will
disappear after cleaning the air inlet and outlet.
Product Usage Instructions
- Make sure to read the user manual before operating the
machine. - Ensure that the machine is connected to the correct rated
voltage and a protected circuit. Refer to Appendix I on page 17 for
grounding instructions. - Operate the machine on a flat, level hard and well-ventilated
surface area, reserve at least 50cm space around the machine and
make sure there is no flammable gas or material nearby. - Do not point the machine at people, animals, or fire when
operating. - Use only accessories recommended or sold by Antari.
- Make sure that the power outlet is not damaged or loose before
plugging in the power cord. If the power cord is damaged, it must
be replaced by Antari or its local dealers, otherwise, the warranty
will be void. - Turn off the power and unplug the power cord immediately if you
experience strange sound or malfunction. Contact your local Antari
dealer for assistance. - To disconnect, turn all controls to the off position, then
remove plug from outlet. Do not unplug by pulling on cord. To
unplug, grasp the plug, not the cord. - Unplug from outlet before servicing or cleaning.
- Ensure that curtain, clothing, cables or other items cannot be
sucked into the fan. - After a period of operation, abnormal noise and uneven air
volume may appear because of dust blocking airflow. Clean the air
inlet and outlet to solve the problem.
AF-3/AF-3X/AF-3S Special Effects Fan User Manual – English
© 2023 Antari Lighting and Effects Ltd.
1. Introduction…………………………………………………………………………………………………………………………………1 2. Safety Information ……………………………………………………………………………………………………………………….1 3. Package Contents & Inspection ……………………………………………………………………………………………………..2 4. Machine Details …………………………………………………………………………………………………………………………..2 5. Technical Label Information………………………………………………………………………………………………………….3 6. Machine Variation ………………………………………………………………………………………………………………………..4 7. Setting and Manual Operation ……………………………………………………………………………………………………….4 8. Control Settings …………………………………………………………………………………………………………………………..4 9. DMX Connection…………………………………………………………………………………………………………………………4 10. Z-3 Cable Remote (Optional) ………………………………………………………………………………………………………..6 11. WTR-10 Wireless Remote (Optional)……………………………………………………………………………………………..6 12. Service and Maintenance ………………………………………………………………………………………………………………7 13. Technical Specifications ……………………………………………………………………………………………………………….8 14. Warranty Disclaimer …………………………………………………………………………………………………………………….8 15. Machine Dimension ……………………………………………………………………………………………………………………..8 1. ……………………………………………………………………………………………………………………………………………9 2. ……………………………………………………………………………………………………………………………..9 3. ………………………………………………………………………………………………………………………..10 4. …………………………………………………………………………………………………………………………………..11 5. ……………………………………………………………………………………………………………………………12 6. …………………………………………………………………………………………………………………………………..12 7. …………………………………………………………………………………………………………………12 8. …………………………………………………………………………………………………………………………………..13 9. DMX ………………………………………………………………………………………………………………………………..13 10. Z-3 () ……………………………………………………………………………………………………………….14 11. WTR-10 ()………………………………………………………………………………………………………..14 12. ……………………………………………………………………………………………………………………………….15 13. …………………………………………………………………………………………………………………………………..16 14. …………………………………………………………………………………………………………………………………..16 15. ……………………………………………………………………………………………………………………………….16 Appendix I – Grounding Instruction …………………………………………………………………………………………………….17
2
User Manual
1. Introduction
Please read all the user manual before operating the machine, and place the manual where the user can refer to it at all time. The manual includes how to install and operate the machine under safe condition and explain all the labels printed on the machine. If you encounter any problem, contact your local Antari dealer for assistant immediately.
2. Safety Information
DANGER If the danger is not avoided, it will cause death or serious injury
WARNING If the warning is not heeded, it can cause death or serious injury.
CAUTION If the precaution is not taken, it may cause minor or moderate injury.
DANGER l Must connect the machine to the correct rated voltage or it might lead to an electrical shock or a burn and may
cause serious consequences. l Must connect the machine to a protected circuit and ensure it is properly grounded to avoid the risk of
electrocution. For grounding instruction, please refer to Appendix I on page 17. l Do not operate the machine with a bundled power cord, it could lead to a fire hazard. l Do not use the fan in an environment full of flammable gas, susceptible to water or powder. Keep away from
any fire and heat sources. l When operating the machine, do not point at people, animals, or fire.
WARNING l Please operate the machine on a flat, level hard and well ventilated surface area, reserve at least 50cm space
around the machine and make sure there is no flammable gas or material nearby. l Do not disassemble, repair or modify the machine, it may cause damages, malfunction, risk of electrical shock
or result in fire. l The machine can only be operated by adults or professionals, is not intended for use by person with reduced
physical sensory, mental capabilities, or lack of experience and knowledge including children. l Do not leave the machine running unattended, make sure all powers are off when leaving. l Children should be supervised to ensure that they do not play with the machine. l Do not use the machine upside down or tilt it, it might cause damages or malfunction. l Never allow any object or part of your body to enter path of the fan blades to prevent any injury or damages l Do not spray the fan with any liquid including cleaner and insecticide to avoid injury or damages.
CAUTION l Keep the machine dry at all time. The machine is not waterproof, do not expose the machine to water, rain, or
moisture environment. l Please make sure the power outlet is not damaged or loose before plug in the power cord. l If the power cord is damaged, it must be replaced by Antari or its local dealers, otherwise the warranty will be
void. l The machine is for indoor use only. l Do not operate the machine in any area with unstable voltage. l If you experience strange sound or malfunction, turn off the power and unplug the power cord immediately
and contact your local Antari dealer for assistant. l Do not contact any moving part.
1
l Only use accessories recommended or sold by Antari. l Please make sure the power is off when not using the machine and unplug the power cord if not intend to use
for a long period of time. l To disconnect, turn all controls to the off position, then remove plug from outlet. l Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. l Unplug from outlet before servicing or cleaning. l Ensure that curtain, clothing, cables or other items cannot be suck into the fan. l Do not operate the machine with a damaged cord or plug, or after the machine malfunctions or is dropped or
damaged in any manner. Return machine to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment. l After a period of operation, abnormal noise and uneven air volume may appear because of dust blocking airflow. It will disappear after cleaning the air inlet and outlet.
Before operating the machine, please read all warning labels on the machine, description as below:
WARNING! 1. Do not allow any object or part of your body get near the protection grill while operating the fan. 2. Operate fan only with adult supervision. 3. Do not use fan without protection grill. 4. Do not use the fan in damp environment.
3. Package Contents & Inspection
Immediately upon receiving the machine, carefully unpack the carton, check the content to ensure it is the correct model and all parts are included. If any part appears to be damaged or missing during transportation, please contact your local dealer and return with original package for inspection.
3.1 Package Contents
AF-3 Compact Effects Fan AF-3X Compact Effects Fan
AF-3S Compact Effects Fan
1 x AF-3 Compact Effects Fan 1 x AF-3X Compact Effects Fan
1 x AF-3S Effects Fan
1 x Neutrik powerCon Cable Connector
1 x User Manual or Scan QR Code on the Machine
3.2 Optional Accessories
Item Code
Description
Z-3
Cable Remote
WTR-10
Wireless Remote (W-1 Transmitter/W-1 Receiver)
4. Machine Details
AF-3
2
01. Adjusting Knob 02. Neutrik powerCon Cable Connector IN 03. Neutrik powerCon Cable Connector OUT 04. XLR 5-Pin DMX 05. Cable Remote Connector 06. Rotary Knob
AF-3X
07. Wirless Connector 08. Ring 09. Bracket 10. Air Inlet 11. Air Outlet
01. Adjust Knob 02. Fuse 03. Neutrik powerCon Cable Connector 04. XLR 5-Pin DMX 05. Cable Remote Connector 06. Rotary Knob
AF-3S
07. Wirless Connector 08. Ring 09. Bracket 10. Air Inlet 11. Air Outlet
01. Adjusting Knob 02. Ring 03. Wireless Connector 04. Rotary Knob 05. Cable Remote Connector 06. XLR 5-Pin DMX
07. Neutrik powerCon Cable Connector IN 08. Neutrik powerCon Cable Connector OUT 09. Air Inlet 10. Air Outlet 11. Bracket
3
5. Technical Label Information
Please read the technical label information on the back of the machine before operating it.
1. Model Name 2. Input Voltage 3. Frequency 4. Rated Power
6. Machine Variation
AF-3 Series Power Supply Available
5. Breaker / Fuse 6. QR CODE for User Manual 7. Serial No.
AF-3X Series Power Supply Unavailable
AF-3S Design for CH-1 with Flight Case
7. Setting and Manual Operation
Step 1. Step 2. Step 3. Step 4. Step 5.
Place the machine on a flat, level hard and well ventilated surface area and reserve at least 50cm open space around the machine, and make sure there is no flammable gas or material nearby; Plug the machine to the power outlet. Please read the technical label on the back of the machine and make sure the power outlet has the correct rated voltage for the machine; Turn on the power, when the status indicator display green indicates the fan is in standby status and ready for operation; To start, turn the rotary knob to the right to increase fan speed and to the left to decrease the fan speed, to stop turn the rotary knob to minimum (-), when fan is in operation the indicator light show orange; To turn off the power, please make sure the machine is not operating. If you will not use the machine a long period of time, please unplug the power cord.
8. Control Settings
AF-3 Series Compact Effects Fan can be operated in the following modes. The machine can only accept 1 type of signal at a time. When using different control modes at the same time, the machine will work according to built-in control priority: l Manual l DMX512 l Wireless l Cable Remote
9. DMX Connection
9.1 DMX Connector Pin Assignment
The machine has a XLR 5-Pin for DMX connection. The diagram below indicates pin assignment information.
4
** There is a protection cap on DMX IN, please remove it with your finger before operation.
Pin
Function
1
Ground
2
Data-
3
Data+
4
N/A
5
N/A
9.2 DMX Setting
DMX Value 0~5 6~254
255
Function Fan off Speed up linearly Maximum speed
9.3 Addressing
Each device occupies 1 channel. To ensure that the control signals are properly directed to each device, they require addressing. This is to be adjusted for every single device by changing the DIP-switches as set out in the table below. The starting address is defined as the first channel from which the device will respond to the controller. Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX data link. If two, three or more devices are addressed similarly, they will work similarly.
Occupation of the DIP-Switches:
DIP
1 2 3 4 5 6 7 8 9
10
Ch.
1 2 4 8 16 32 64 128 256 Wireless pairing, control on/off
SW.
11
ON
2 CH Mode
OFF
1 CH Mode
12 Wireless Pairing
No Function
5
Device Number & Channels Device 1 Channel 1 Device 2 Channel 2 Device 3 Channel 3 Device 4 Channel 4 Device 5 Channel 5
Staring Address
On Off On Off On Off On Off On Off
1 2 4 8 16 32 64 128 256
10. Z-3 Cable Remote (Optional)
Z-3 Cable Remote is an optional accessory for AF-3/AF-3X Special Effects Fan, please see instruction below; 1. Plug the cable remote to the connector on the back of the machine; 2. Press the red button to turn the power of the remote on, red indicator light is solid; 3. You can start to turn the knob to activate the fan and adjust the fan speed. ** If you encounter any problem, please contact your local Antari dealer for assistant
11. WTR-10 Wireless Remote (Optional)
WTR-10 Wireless Remote is an optional accessory for AF-3/AF-3X Special Effects Fan, it included a W-1 wireless transmitter and a W-1 wireless receiver. If you already purchased the wireless model, it’s ready to use. If you purchase the WTR-10 Wireless Remote afterwards, please follow the instruction below. If you encounter any problem, please contact your local Antari dealer for assistant.
6
11.1 W-1 Wireless Transmitter & Receiver
l Battery27A 12V l Effective RangeThe effective range is approximately 50m,
depends on actual condition, it may vary. l W-1 wireless transmitter has 2 buttons, each function as follow:
Button [A] [B]
Function Start Fan Stop Fan
W-1 Wireless Transmitter
11.2 W-1 Wireless Receiver Installation
W-1 Wireless Receiver
If you purchased the WTR-10 Wireless Remote afterwards, please follow the instructions below to install the receiver. If you encounter any problem, please contact your local Antari dealer for assistant.
Graph 1
Graph 2
Graph 3
1. Please see graph 1, remove the cover from the pointed place; 2. You will see a white cable like graph 2, pull it out and connect to the W-1 receiver; 3. Screw it back to the machine like graph 3 and follow the instruction on 11.3 for pairing.
11.3 Pair & Unpair
Each receiver can pair up to 5 transmitters, please follow the steps below to pair or unpair the remote;
Step 1. Step 2.
Step 3. Step 4.
Set DIP switch No.10 to “ON” position; Status will show red light for 10 seconds, press “A” or “B” on the transmitter to pair it; status indicator will show green light if pair is successful; If you want to pair extra transmitter, turn DIP switch No.10 to “OFF” position first and repeat Step 2.; To unpair, set DIP switch No.10 to “OFF” position;
12. Service and Maintenance
DANGER! Disconnect the power cord before starting maintenance operation!
l Always keep the machine clean. l Can use an air compressor, a vacuum or a soft brush to remove the dust on the machine. l Can use a slightly damp cloth to clean the casing. l It is recommended to run the machine at least once a month in order to maintain its best performance and
output condition. l Excessive dust will reduce the performance and cause overheat.
7
13. Technical Specifications
Rated Voltage
Rated Power Ambient Temp. Range Air Flow Fan Speed Noise Level Control Methods Interface DMX Channel Included Accessories Optional Accessories
Dimension
Weight
AF-3/AF-3X US Model : AC 100-120V, 50/60Hz 1.5A EU Model : AC 220-240V, 50/60Hz 1.0A 127W
AF-3S
0°C – 40°C (32°F – 104°F)
530 CFM (50Hz)600 CFM (60Hz)
750 – 2550 rpm (50Hz)750 – 2800 rpm (60Hz)
72.6 dB (Max. Output)
ManualDMX512Wireless (Optional)Cable Remote (Optional)
XLR 5-Pin (DMX)Neutrik powerCon (Power)
1 Channel
N/A
Z-3 Cable RemoteWTR-10 Wireless Remote
L 124 W 316 H 368 mm (L 4.88 W 12.44 H 14.49 inch)
L 160 W 312 H 336 mm (L 6.29 W 12.28 H 13.24 inch)
6.0 kg (13.23 lbs.)
6.4 kg (14.00 lbs.)
14. Warranty Disclaimer
We guarantee the merchandise manufactured by us to be free from defect in material and workmanship for a period of one year. Our obligation and liability under this warranty shall be restricted to repair or replacement at our factory or local authorized dealer. We assume no liability of the products that are improperly used or used for any purpose other than that for which they are specially designed. This warranty shall not apply to any merchandise which has been repaired, altered or assembled outside our factory in any way so as in our judgment to affect its performance, nor which has been subjected to misuse, negligence, or accident nor to any merchandise operated contrary to our printed instructions. We will not allow or be liable of any loss or any damages of any kind in connection with the use, sale, or repair of any merchandise purchased from us.
15. Machine Dimension
AF-3/AF-3X
AF-3S
8
1.
Antari
2.
l l
17 I l l l
l
l l
() l l l l l
l l l l
9
l l
Antari l l l l l l l l
l
WARNING! ! 1. Do not allow any object or part of your body get near the protection grill while operating the fan.
2. Operate fan only with adult supervision. 3. Do not use fan without protection grill. 4. Do not use the fan in damp environment.
3.
3.1
AF-3 1 x AF-3
AF-3X 1 x AF-3X 1 x Neutrik powerCon 1 x QR Code
AF-3S 1 x AF-3S
3.2
Z-3 WTR-10
(W-1 /W-1 )
10
4.
AF-3
01. 02. Neutrik powerCon OUT 03. Neutrik powerCon IN 04. XLR 5-PIN DMX 05. 06.
AF-3X
07. 08. 09. 10. 11.
01. 02. 03. Neutrik powerCon 04. XLR 5-PIN DMX 05. 06.
07. 08. 09. 10. 11.
11
AF-3/AF-3S
01. 02. 03. 04. 05. 06. XLR 5-PIN DMX
07. Neutrik powerCon IN 08. Neutrik powerCon OUT 09. 10. 11.
5.
1. 2. 3. 4.
5. 6. QR CODE 7.
6.
AF-3
AF-3X
AF-3S CH-1
7.
1. 2. 3. 4. 5.
50 ; ; (-); ;
12
8.
AF-3/AF-3X ; l l DMX512 l l
9. DMX
9.1 DMX
XLR 5-PIN DMX PIN
DMX IN
Pin
1
2
–
3
+
4
N/A
5
N/A
9.2 DMX
DMX 0~5 6~254 255
9.3 DMX
DMX
:
DIP
1 2 3 4 5 6 7 8 9
10
Ch.
1 2 4 8 16 32 64 128 256 Wireless pairing, control on/off
SW.
11
ON
2 CH Mode
OFF
1 CH Mode
12 Wireless Pairing
No Function
13
Setting the DMX-Starting Address
Device Number & Channels Device 1 Channel 1
Device 2 Channel 2
Device 3 Channel 3
Device 4 Channel 4
Device 5 Channel 5
DIP-Switch No.
Staring Address On Off On Off On Off On Off On Off
10. Z-3 ()
1 2 3 4 5 6 7 8 9
1 2 4 8 16 32 64 128 256
Z-3 AF-3/AF-3X ; 1. ; 2. ; 3. ** Antari
11. WTR-10 ()
WTR-10 W-1 W-1 AF-3/AF-3X WTR-10 Antari
14
11.1 W-1 &
l 27A 12V l 50
l W-1 2
[A] [B]
W-1
11.2 W-1
W-1
WTR-10 Antari
Graph 1
Graph 2
Graph 3
1. ; 2. W-2 ; 3. 11.3
11.3 &
5 ;
1 10 “ON”; 2 10 “A””B”
; 3 10 “OFF” 2 4 10 “OFF”
12.
!
l l l
15
l l
13.
DMX512
AF-3/AF-3X
AF-3S
: AC 100-120V, 50/60Hz 1.5A
: AC 220-240V, 50/60Hz 1.0A
127
0°C 40°C (32°F 104°F)
530 / (50 )600 /(60 )
750-2550 (50 )750-2800 (60 )
72.6 ()
DMX512()()
XLR 5-PIN(DMX)Neutrik powerCon()
1
Z-3 WTR-10
124 316 368
160 312 336
( 4.88 12.44 14.49 )
( 6.29 12.28 13.24 )
6.0 (13.23 )
6.4 (14.00 )
14.
15.
AF-3/AF-3X
AF-3S
16
Appendix I – Grounding Instruction
This appliance must be grounded. In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. DANGER Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipmentgrounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipmentgrounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance is for use on a nominal 120 V circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.
17
C08AF3S001