Portor Lighting Pt-blp6-3cp Series 2 Foot X 2 Foot Led Back Lit Flat Panel Instruction Manual

PT-BLP6-3CP Series 2 foot x 2 foot LED Back Lit Flat Panel

Product Information

The PT-BLP6-3CP (EM) SERIES is a LED luminaire designed for
installation in T-bar ceiling grids. It operates at a voltage range
of 120-277V and comes in three models: PT-BLP6-24, PT-BLP6-22, and
PT-BLP6-14. The luminaire features a dimming capability using a
0-10V IEC compliant control.

The luminaire includes an LED driver with multiple wire
connections. The black wire is for the line, the green wire is for
ground, the purple wire is for dimming positive, the pink wire is
for dimming negative, and the black, grey, and (+) wires are for
other connections.

The installation of the luminaire requires careful handling and
following safety precautions. It is important to turn off the power
supply from the main circuit breaker before starting the
installation process. The luminaire should be inspected for any
defects and cleaned if necessary using a dry cotton cloth and
gloves.

The mounting clips on the sides of the luminaire should be
lifted up to insert it into the T-bar ceiling grid. A safety cable
should be secured as required to meet local seismic requirements
and building codes.

The electrical enclosure cover should be removed to access the
AC line input wires and 0-10V control line. Listed electrical
fittings can be installed in the knockout holes for wire protection
if needed. The AC line (L, N, and GND) should be connected to the
LED driver using 18-14AWG wire. The 0-10V dimming controller wires
should be connected through a separate knockout hole.

After completing the wire connections, the electrical enclosure
cover should be returned and tightened securely.

The PT-BLP6-3CP (EM) SERIES also includes an emergency battery
back-up feature. The wiring diagram for the emergency LED driver,
test switch, and LED module is provided. The luminaire also offers
CCT tunable and wattage selection options with factory settings of
5000K @ 25W. The desired CCT and wattage can be adjusted using the
provided connectors.

Product Usage Instructions

  1. Before installation, ensure that the power supply from the main
    circuit breaker is turned off.
  2. Carefully unpack the luminaire and inspect it for any defects.
    Use work gloves to prevent dirt and oil transfer. Clean with a dry
    cotton cloth if necessary.
  3. Lift up the four mounting clips on the sides of the luminaire
    to prepare for installation.
  4. Insert the luminaire into the T-bar ceiling grid. Secure a
    safety cable if required by local seismic requirements and building
    codes.
  5. Remove the electrical enclosure cover and remove the knockout
    for AC line input wires and 0-10V control line.
  6. If needed, install listed electrical fittings in the knockout
    holes for wire protection.
  7. Connect the AC line (L, N, and GND) to the LED driver using
    18-14AWG wire. Connect the wires from the 0-10V dimming controller
    through a separate knockout hole.
  8. Follow the wire connection instructions provided for proper
    installation.
  9. Return the electrical enclosure cover and tighten the screws
    securely.
  10. If applicable, adjust the CCT and wattage settings using the
    provided connectors.

For more information and updates, please visit www.portorlighting.com.

INSTALLATION INSTRUCTIONS

PT-BLP6-3CP (EM) SERIES
PT-BLP6-24 / PT-BLP6-22 / PT-BLP6-14

GENERAL WIRING DIAGRAM

120-277V

Black (Line) Green (Ground)

LED Driver

Purple (Dim +) Pink (Dim -) Black (-) (+) Grey (-)

Dimming wire to 0-10V IEC compliant control

Lead wire to LED load

WARNING
· TO REDUCE THE RISK OF DEATH, PERSONAL INJURY OR PROPERTY DAMAGE FROM FIRE, ELECTRIC SHOCK, FALLING PARTS, CUTS/ABRASIONS, AND OTHER HAZARDS READ ALL WARNINGS AND INSTRUCTIONS INCLUDED WITH AND ON THE FIXTURE BOX AND ALL FIXTURE LABELS. · BEFORE INSTALLING, SERVICING, OR PERFORMING ROUTINE MAINTENANCE UPON THIS EQUIPMENT, FOLLOW THESE GENERAL PRECAUTIONS. · COMMERCIAL INSTALLATION, SERVICE AND MAINTENANCE OF LUMINAIRES SHOULD BE PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN. · FOR THE INSTALLATION: IF YOU ARE UNSURE ABOUT THE INSTALLATION OR MAINTENANCE OF THE LUMINAIRES, CONSULT A QUALIFIED LICENSED ELECTRICIAN AND CHECK YOUR LOCAL ELECTRICAL CODE. · TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARP OBJECTS. · DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING KIT INSTALLATION.
WARNING
· TURN OFF ELECTRICAL POWER AT FUSE OR CIRCUIT BREAKER BOX BEFORE WIRING FIXTURE TO THE POWER SUPPLY.
· TURN OFF THE POWER WHEN YOU PERFORM ANY MAINTENANCE. · VERIFY THAT SUPPLY VOLTAGE IS CORRECT BY COMPARING IT WITH THE LUMINAIRE LABEL INFORMATION. · ALL WIRING CONNECTIONS SHOULD BE CAPPED WITH UL APPROVED WIRE CONNECTORS.
CAUTION
· AVOID DIRECT EYE EXPOSURE TO THE LIGHT SOURCE WHILE IT IS ON. · ACCOUNT FOR SMALL PARTS AND DESTROY PACKING MATERIAL, AS THESE MAY BE HAZARDOUS
TO CHILDREN. · RISK OF BURN. DISCONNECT POWER AND ALLOW FIXTURE TO COOL BEFORE CHANGING BULB OR
HANDING FIXTURE.

INSTALLATION (ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!)

1. Carefully unpack unit and properly inspect for
defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire. If cleaning is needed, use gloves and a dry cotton cloth. It is not recommended to use hazardous chemicals.

2. Lift up four mounting clips on the sides of the
luminaire. You can do it by hand (Do wear work gloves) or use pliers.

3. Insert luminaire into T-bar ceiling grid. Secure
safety cable to connection hole as needed to meet local seismic requirements. Safety cable and method of attachment to the building provided by contractor according to local building codes.

4. Remove electrical enclosure cover. Carefully
remove knockout for AC line input wires and 0-10V control line. Install listed electrical fittings in the knockout holes for wire protection if needed.

5. Plug in AC line(L and N,and GND) to the LED Driver
using 18-14AWG Wire. When connecting 0-10Vdimming controller, wires must run through a separate knockout hole equipped with an appropriate electrical fitting.

6. Follow wire connection instructions. When using
the 0-10V dimming controller Run wires from controller through a different knockout than the AC input wire. Don t forget to return the electrical enclosure cover and tighten the screws.

www.portorlighting.com

AC line

LED Driver

Gnd ACL ACN
Dim + Dim –
LED LED + LED –

Green Black White
To 0-10V Dimmer

Specification subject to change without notice

1/2

INSTALLATION INSTRUCTIONS

PT-BLP6-3CP (EM) SERIES
PT-BLP6-24 / PT-BLP6-22 / PT-BLP6-14

EMERGENCY BATTERY BACK-UP

Emergency LED Driver

Test switch

WIRING DIAGRAM

L

Red

Black

N

White

White & Blue

Black White

White Gray Black Purple Pink

Violet Gray
Connector

LED Module
LED Indicator & Test Switch

3500K 5000K

Brown Blue
Brown White

CCT TUNABLE AND WATTAGE SELECTOR

30W 25W 20W

FACTORY SETTINGS: 5000K @ 25W
· DIP switches are located onto the drive box. · Select a wattage and color temperature by sliding switch left or
right respectively to the desired value.

3500K-5000K

www.portorlighting.com

Specification subject to change without notice

2/2