Kern Eg2200-2nm Precision Balance Owner's Manual

EG2200-2NM Precision Balance

Product Information

Product Name: KERN EG2200-2NM

Description: The classic balance with robust
tuning fork measuring system

Measuring System: Eccentric loading at 1/3
[Max]

Adjustment Options: Linearity, Minimum weight
(USP)

Readability: 30 mg

Repeatability: 10 mg

Resolution: 10 mg

Stabilisation Time under Laboratory Conditions:
3 seconds

Warm Up Time: 2 hours

Weighing Capacity: 2,200 kg

Weighing Units: tol, g, mo, lb, tl (Singap.
Malays), dwt, ct, tl (Tw), oz, ozt, tl (HK)

Display Digit Height (Large): 1,700 cm

Verification Minimum Load: 500 mg

Periodic Verification for Italy: 969-112

Verification Approval Conforming to 2014/31/EU:
Yes

Verification by KERN Possible: Yes

Verification Class: II

Verification Value [e]: 100 mg

Counting Resolution: 220000

Minimum Piece Weight at Piece Counting
(Laboratory):
10 mg

Minimum Piece Weight at Piece Counting
(Normal):
100 mg

Functions: Capacity display, Counting function,
Percentage determination, Weighing with tolerance range

Environmental Conditions: Maximum humidity:
80%, Maximum operating temperature: 30°C, Minimum ambient
temperature: 10°C

Power Supply: Charging time: 12 hours, Input
voltage: 220 V – 240 V AC 50 Hz, Mains adapter: external EURO CH US
UK, Mains adapter/adapter included: yes, Operating time (Backlight
off): 32 hours, Operating time (Backlight on): 12 hours,
Rechargeable battery: optional

Services (Optional): DAkkS Certificate:
963-127, Verification: 965-216

Category: Brand: KERN Balances, Category:
Precision balance, Product Group: 1

Packaging & Shipping: Delivery: 24 hours,
Dimensions packaging (WxDxH): 325 x 410 x 220 mm, Gross weight:
5,050 kg, Net weight: 3,840 kg, Shipping method: Parcel service

Product Usage Instructions

To use the KERN EG2200-2NM balance:

  1. Ensure the balance is placed on a stable surface.
  2. Power on the balance using the provided mains adapter.
  3. Wait for the balance to warm up for 2 hours.
  4. Place the item to be weighed on the weighing plate.
  5. Wait for the balance to stabilize under laboratory conditions,
    which takes approximately 3 seconds.
  6. Read the weight value displayed on the large digit height
    display.
  7. If needed, you can adjust the balance using the eccentric
    loading at 1/3 of the maximum capacity.
  8. For piece counting, ensure the minimum piece weight is met
    either in laboratory conditions (10 mg) or normal conditions (100
    mg).
  9. The balance also offers functions such as capacity display,
    counting function, percentage determination, and weighing with a
    tolerance range. Refer to the user manual for instructions on using
    these functions.
  10. After use, power off the balance and disconnect it from the
    mains adapter.

Note: The optional rechargeable battery can be used for
operating the balance without a mains power source. Verify and
calibrate the balance periodically according to the provided
verification information.

KERN EG2200-2NM
The classic balance with robust tuning fork measuring system

Measuring system
Adjustment options: Eccentric loading at 1/3 [Max]: Linearity: Minimum weight (USP): Readability [d]: Repeatability: Resolution: Stabilisation time under laboratory conditions: Warm up time: Weighing capacity [Max]: Weighing units:

Internal calibration (manual) 30 mg 10 mg 20 g 10 mg 10 mg 220000 3s
2h 2,200 kg tol g mo lb tl (Singap. Malays) dwt ct tl (Tw) oz ozt tl (HK)

Display
Display digit height (large):

1,700 cm

Technical data about verification

Minimum load [Min]: Periodic Verification for Italy: Verification approval conforming to 2014/31/EU: Verification by KERN possible: Verification class: Verification value [e]:

500 mg 969-112 yes
yes II 100 mg

Counting
Counting resolution: Mininum piece weight at piece counting (Laboratory: Mininum piece weight at piece counting (Normal):
Functions
Capacity display: Counting function: Percentage determination: Weighing with tolerance range:
Environmental conditions
Maximum humidity: Maximum operating temperature: Minimum ambient temperature:
Power supply
Charging time: Input voltage: Mains adapter: Mains adapter/adapter included: Operating time (Backlight off): Operating time (Backlight on): Rechargeable battery:
Services (optional)
DAkkS Certificate: Verification:
Category
Brand: Category: Product Group:
Packaging & shipping
Delivery: Dimensions packaging (WxDxH): Gross weight: Net weight: Shipping method:

220000 10 mg
100 mg
yes yes yes yes
80 % 30 OC 10 OC
12 h 220 V – 240 V AC 50 Hz Mains adapter external EURO CH US UK 32 h 12 h Rchrg. battery optional
963-127 965-216
KERN Balances Precision balance
24 h 325 x 410 x 220 mm 5,050 kg 3,840 kg Parcel service

KERN & SOHN GmbH . Ziegelei 1 . 72336 Balingen . Germany . Tel. +49­(0)7433 – 99 33-0 . www.kern-sohn.com

1

KERN EG2200-2NM
The classic balance with robust tuning fork measuring system

Construction
Casing material: Dimensions housing (WxDxH): Level indicator: Material weighing plate: Revolving screw feet: Weighing surface (WxD):
Piktogramme
STANDARD

Plastic 265 x 192 x 87 mm yes stainless steel yes 180 x 160 mm

OPTION FACTORY

KERN & SOHN GmbH . Ziegelei 1 . 72336 Balingen . Germany . Tel. +49­(0)7433 – 99 33-0 . www.kern-sohn.com

2

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.