Euri Lighting Efl-230w-md Led Flame Lantern Installation Guide

EFL-230W-MD LED Flame Lantern

Product Information

The LED Flame Lantern is an outdoor wall light fixture from the
Eurilighting LED Fixtures series. It is available in two models:
EFL-230W-MD and EFL-240W-MD. The lantern features a flame bulb
design and is suitable for use in various outdoor applications.

The lantern is equipped with a motion sensor and a photocell
sensor for automatic lighting control. It has a detection range of
approximately 5.9 to 7.2 feet and can be adjusted for different
distances using the sensor switches.

For more information about the product, please visit www.eurilighting.com or contact
their toll-free number: 1-888-743-5766.

Product Usage Instructions

Installation Guide

  1. Before starting the installation, make sure to cut off power to
    the fixture.
  2. For the Lantern installation:
    1. Mount the provided mounting plate to the junction box.
    2. Connect the wires using all three wire nuts (positive, neutral,
      and ground).
    3. Install the fixture body and tighten the screw nuts
      securely.
  3. For the Flame Bulb installation:
    1. Cut off power before installation.
    2. Move the E12 base to the side and screw the flame lamp into the
      socket.
    3. Turn the E12 base back to its original position.
  4. To prevent water penetration, seal the fixture by applying
    caulk between the fixture back plate and the wall surface using a
    silicone sealant (not included).

Troubleshooting

Problem: In motion sensing mode, the light does
not turn on when there is motion.

Possible Cause:

  • The wall switch of the circuit breaker is off.
  • Incorrect or loose wire connections.
  • Too much sunlight shining into the photocell sensor in the
    early evening.
  • Too much light shining onto the photocell sensor due to another
    light source.
  • Motion sensor is mounted too high, and moving persons or
    vehicles are below its view.

Corrective Action:

  • Turn on the switch or circuit breaker.
  • Check wire connections.
  • Relocate the fixture away from a western facing wall.
  • a. Eliminate or turn off any other light sources.
    b. Block other light sources from shining onto the photocell
    sensor.
    c. Test the fixture in a different location.
  • Adjust the height of installation.

Problem: In motion sensing mode, the light
stays on continuously.

Possible Cause: False triggering caused by a
heat source, such as a heater or dryer vent, or heated swimming
pool.

Corrective Action:

  • Eliminate the heat source.
  • Test the fixture in a different location.

Problem: The light comes on for no apparent
reason.

Possible Cause:

  • Street or sidewalk traffic is triggering the motion
    sensor.
  • False triggering caused by a heat source, such as a heater or
    dryer vent, or heated swimming pool.

Corrective Action:

  • Eliminate the heat source.
  • Test the fixture in a different location.

Problem: The light comes on during the daytime
or too early in the evening.

Possible Cause: The fixture may be installed in
a shaded area, such as under a porch or eave, preventing daylight
from shining onto the photocell sensor.

Corrective Action: Test the fixture in a
different location.

INSTALLATION GUIDE
MODEL #: EFL-230W-MD / EFL-240W-MD

LED Fixtures | Outdoor Wall Light Series Flame Bulb Lantern Class

Questions? For customer service please call us at 1-888-743-5766 Office Hours: 8:00 a.m. ­ 5:00 p.m. PST Monday-Friday
www.eurilighting.com

LED FLAME
LANTERN

PLEASE REVIEW THE INSTRUCTIONS AND WARNINGS LISTED BELOW PRIOR TO PROPER INSTALLATION

WARNINGS

CAUTIONS

· Risk of fire / electrical shock · LED Fixture installation requires knowledge of luminaire electrical
systems. · Risk of electric shock ­ disconnect power at source before installation. · Do not make or alter any open holes in an enclosure of wiring or
electrical components during installation. · If lamp or luminaire exhibits abnormal operation (buzzing, flickering,
minimal light, etc.), turn off power, remove lamp and contact us. For more information please visit www.eurilighting.com or call our toll-free number 1-888-743-5766.

· Do not use with dimmers. · Do not look directly at the operating LED Light Source. · Do not touch this product with wet hands. · Do not disassemble, repair, or alter lamp. · Designed for outdoor applications only. · Suitable for wet locations. · The luminaires shall be grounded. · Be careful not to touch the lamp pins to the metal housing when installing. · This Device is not intended for use with emergency exits or
emergency lights.

OPERATING INSTRUCTIONS
· The motion sensor on this fixture has a built-in Dusk-to-Dawn sensor that automatically disables the motion sensor during daylight hours regardless if motion is detected.
· The 120-degree coverage of the motion sensor is measured side to side. Therefore, the sensor will be better at detecting motion across the field of view (side-to-side), rather than movement coming straight at the sensor (in-and-out).
TROUBLESHOOTING

· Extreme hot or cold weather can affect the performance of the built-in sensors that detect body heat. Certain winter clothing can shield a person’s body heat from the sensor during extremely cold weather. During extremely hot weather, the sensor may not be able to distinguish the difference between normal body temperatures and surrounding high temperatures. The sensor will begin working normally once weather conditions return to normal.

PROBLEM
In motion sensing mode, the light does not turn on when there is motion.

POSSIBLE CAUSE

CORRECTIVE ACTION

1. The wall switch of the circuit breaker is off. 2. Incorrect or loose wire connections. 3. Too much sunlight is shining into the photocell sensor in the
early evening. 4. Too much light is shining onto the photocell sensor due to
another light source, such as a street lamp or other light fixture. 5. Moving persons or vehicles are below the view of the motion
sensor because the motion sensor is mounted too high.

1. Turn on the switch or circuit breaker. 2. Check wire connections. 3. Relocate fixture away from a western facing wall. 4. a. Eliminate or turn off any other light sources.
b. Block other light sources from shining onto the photocell sensor.
c. Test the fixture in a different location. 5. Adjust the height of installation.

In motion sensing mode, the light stays on continuously.

False triggering is caused by a heat source, such as a heater of a a. Eliminate heat source.

dryer vent, or heated swimming pool.

b. Test the fixture in a different location.

The light comes on for no apparent reason.

1. Street of sidewalk traffic is triggering the motion sensor. 2. False triggering caused by a heat source, such as a heater or
dryer vent, or heated swimming pool.

a. Eliminate heat source. b. Test the fixture in a different location.

The light comes on during the daytime or too early in the evening.

The fixture may be installed in a shaded area, such as under a porch or eave, preventing daylight from shining onto the photocell sensor.

Test the fixture in a different location.

PRODUCT ILLUSTRATIONS REPRESENTED IN THIS INSTALLATION GUIDE MAY VARY IN SIZE DEPENDING ON MODEL NUMBER. INSTALLATION REMAINS THE SAME. ©2021. Euri Lighting | A Division of IRTRONIX Inc. All Rights Reserved

INSTALLATION GUIDE
MODEL #: EFL-230W-MD / EFL-240W-MD

LED Fixtures | Outdoor Wall Light Series Flame Bulb Lantern Class

Questions? For customer service please call us at 1-888-743-5766 Office Hours: 8:00 a.m. ­ 5:00 p.m. PST Monday-Friday
www.eurilighting.com

LED FLAME
LANTERN

PLEASE REVIEW THE INSTRUCTIONS AND WARNINGS LISTED BELOW PRIOR TO PROPER INSTALLATION

SENSOR FUNCTION AND SPECIFICATIONS

PRODUCT INSTALLATION DETECTION FIGURE

· Power Capacity : Integrated Light Engine ­ Max 40W LED / E12 Candle Lamp ­ Max 10W LED
· Test Mode : First, power up the LED Flame Lantern. The security light will turn on for 15±8 seconds, and the sensor will be calibrating during this time. The security light will turn off once the sensor calibration has completed. After cycling through the test mode, please select your desired setting and adjust the sensor sensitivity, if applicable.
· Dual Mode : At dusk, when the ambient light falls below 60 Lux, only the flame bulb will activate. When the sensor detects motion, the flame bulb will deactivate, and the security light will activate. The security light will stay on for 30±10 seconds and shift back to the flame bulb mode once motion is no longer detected. If movement is continuously detected, the security light will remain on, turning off 30 seconds after the last detected activity. When the ambient light reaches 600 Lux, both light sources will be disabled after 60±10 seconds until the following evening.
· Flame Mode : In the evening, when the ambient light falls below 60 Lux, the flame bulb will activate. The security light will remain off, even when motion is detected as the manual override is selected. When the ambient light reaches 600 Lux, the flame bulb will turn off until the following evening.
· Security Mode : In the evening, when the ambient light falls below 60 Lux, the Security light will activate. The flame bulb will remain off, even when no motion is detected, as the manual override is selected. When the ambient light reaches 600 Lux, the security light will remain off until the following evening.
· Detection Range : When the fixture is mounted 6 to 7 feet off the ground, the motion sensor range is as follows: Low (L): 3 to 10 feet; Medium (M): 10 to 20 feet; High (H): Over 20 feet with a max of 120° viewing range from the mounting application.
Acceptance standard of induction distance: When the ambient temperature is 77°F, the standard range is Low (L): 3 to 10 feet, Medium (M): 10 to 20 feet, High (H): Over 20 feet.

Ý

Ý 80Ý 70Ý 60Ý 50Ý
PIR SENSOR 5.9~7.2ft
SENSOR SWITCHES

80Ý

1M

2M

70Ý

3M

60Ý

4M

Ý

5M

40Ý

6M

Ý

30Ý

7M

30Ý

20Ý

20Ý

8ÝM 10Ý

10Ý

PIR SENSOR PIR SENSOR

Direction of travel

*Please note, with different air temperatures, the motion sensor range will slightly vary.

INSTALLATION INSTRUCTIONS

1

2

3

4

Fixture Installation (Lantern)
1. Please cut off power to the fixture before beginning installation. 2. Install the mounting plate to the junction box. 3. Connect the wires using all three wire nuts (positive, neutral, and ground). 4. Install the fixture body and screw nuts tightly.

Fixture Installation (Flame Bulb)
1. Please cut off power before installation. 2. Move the E12 base to the side and screw flame lamp into socket. 3. Turn the E12 base to original position.

Seal the fixture Caulk between the fixture back plateand the wall surface to prevent water penetration. Use a silicone sealant (Not include).