Westinghouse Igen2500c Portable Inverter Generator User Guide

Westinghouse Igen2500c Portable Inverter Generator User Guide

Westinghouse iGen2500c Portable Inverter Generator logo

Westinghouse iGen2500c Portable Inverter Generator

Westinghouse iGen2500c Portable Inverter Generator product

BEFORE STARTING

Add engine oil. 

  • Loosen the screws and remove the engine service panel to access the oil/fill drain plug.Westinghouse iGen2500c Portable Inverter Generator fig 1
  • Remove oil fill plug/dipstick Westinghouse iGen2500c Portable Inverter Generator fig 2
  • Using the supplied 4-cycle engine oil and funnel, slowly add engine oil to the engine until full.
  • Do not overfill, if oil level is too high, oil will drain out through the fill plug.

Add unleaded gasoline to gas tank. 

  • Unscrew gas cap on top of tank and insert a clean funnel into the tank. Westinghouse iGen2500c Portable Inverter Generator fig 3
  • Slowly add gasoline into the fuel tank. The gasoline level should NOT be higher than the filler neck. Westinghouse iGen2500c Portable Inverter Generator fig 4
  • Secure gas cap.

STARTING PROCEDURE

  1. Make sure the generator is OUTSIDE in a well ventilated dry area and FAR AWAY from any doors, windows, or vents.
  2. Check fuel and oil levels.
  3. Make sure nothing is plugged into power outlets.
  4. Make sure the circuit breakers are properly set to operating.-Westinghouse iGen2500c Portable Inverter Generator fig 5
  5. Turn Eco Mode OFF.
  6. If the inverter has a fuel tank vent on top of the gas cap, turn it to the ON position. Westinghouse iGen2500c Portable Inverter Generator fig 8
  7. Turn the engine/fuel control switch to the CHOKE Westinghouse iGen2500c Portable Inverter Generator fig 6position. If the engine is warm turn  the switch to the RUN  Westinghouse iGen2500c Portable Inverter Generator fig 7 position.
  8. Manual Start: Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling up and slightly away from the generator.Westinghouse iGen2500c Portable Inverter Generator fig 9
  9. After the engine starts, gradually move the engine/fuel control switch to the RUNWestinghouse iGen2500c Portable Inverter Generator fig 7 position.
  10. Plug in electronic devices.

MAINTENANCE SCHEDULE

Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals. Refer to the Maintenance section in the Owners Manual to find out how to properly perform maintenance.

Maintenance ItemBefore Every UseAfter First 25 Hours or First Month of UseAfter 50 Hours of Use or Every 6 MonthsAfter 100 Hour of Use or Every 6 MonthsAfter 300 Hours of Use or Every Year
Engine OilCheck LevelChange1Change
Air FilterClean2Replace
Spark PlugCheck/CleanReplace
Spark ArrestorCheck/Clean
Fuel FilterReplace3
Valve ClearanceInspect/Adjust3
  1. Change oil every month when operating under heavy loads or in high temperatures.
  2. Clean more often under dirty or dusty conditions.
  3. Recommended service by authorized Westinghouse dealer.

ENGINE OILWestinghouse iGen2500c Portable Inverter Generator fig 10

Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL. Synthetic oil is an acceptable substitute for conventional oil.