CFN-1101 52 Inch Integrated LED Nickel Ceiling Fan
V20220704 CFN-1101 Instruction Manual
Introduction:
This product requires careful installation and usage. Before
installation, please read the package list on Page 2 and ensure all
parts are present and display no defects. If any part is missing or
damaged, contact customer service and do not attempt to install the
product. Also, read all of the safety information on Page 3 before
installation or use.
Estimated assembly time: 120 minutes
Additional tools required for assembly:
- Electrical tape
- Flathead & Phillips screwdriver
- Pliers
- Safety glasses
- Ladder
- Wire strippers
Additional helpful tools:
- AC tester light
- Tape measure
- Wiring handbook
- Wire cutters
1. Package Contents:
- Fan Motor Assembly
- Light Plate
- Glass Shade
- LED Light Kit
- MED LOW LI HI STOP 2H 1H 4H R/F Remote Control
- Receiver
- Balance Kit
2. Safety Information:
Warning!
- To reduce the risk of electric shock, ensure electricity has
been turned off at the circuit breaker or fuse box before
beginning. - All wiring must be in accordance with national and local
electrical codes. Electrical installation should be performed by a
qualified licensed electrician. - This fan is suitable for use with solid-state speed
controls. - To reduce the risk of personal injury, use only the screws and
washers provided with the junction box for mounting to the junction
box. Most junction boxes commonly used for the support of lighting
fixtures are not acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt. - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, &
PERSONAL INJURY, MOUNT FAN TO AN JUNCTION BOX MARKED ACCEPTABLE FOR
FAN SUPPORT. - The junction box and support structure MUST be securely mounted
and capable of reliably supporting a minimum of 50 pounds. Use only
UL listed junction boxes marked FOR FAN SUPPORT. - After marking electrical connections, spliced conductors should
be turned upward and pushed carefully up into junction box. The
wires should be spread apart with the grounded conductor and the
equipment-grounding conductor on one side of the junction box. - The fan must be mounted with a minimum of 7 feet clearance from
the trailing edge of the blades to the floor. - Do not use the reverse switch while the fan blades are in
motion. To prevent damage and ensure long use, the fan must be
turned off and the blades stopped before reversing direction. - Do not place objects in the path of the blades.
- Exercise caution when working around or cleaning the fan.
- Use a soft dry cloth to clean the fan body and blades. Do not
use water or detergent. - The electrical diagrams provided herein are for reference only.
Light kits that are not packaged with the fan must be UL listed and
suitable for use with this fan. Switches must be UL general use
switches. Refer to their separate instructions for proper
assembly. - NEVER BEND THE BLADE BRACKETS/FLANGES FOR ANY
REASON.
3. Preparation:
- Turn off Your Power: Begin installation by removing fuses or
turning off circuit breakers to the wiring you will be using. Use
your compatible UL listed junction box if you already have one
installed.
Product Usage Instructions:
- Before using the product, ensure that all parts are present and
display no defects. If any part is missing or damaged, contact
customer service and do not attempt to use the product. - Read all of the safety information carefully before
installation or use. - Use additional tools required for assembly, including
electrical tape, flathead & Phillips screwdriver, pliers,
safety glasses, ladder, and wire strippers. Additional helpful
tools include an AC tester light, tape measure, wiring handbook,
and wire cutters. - Begin installation by turning off the electricity at the
circuit breaker or fuse box and using a compatible UL listed
junction box if already installed. - Mount the fan to a junction box marked acceptable for fan
support, ensuring that the junction box and support structure are
securely mounted and capable of reliably supporting a minimum of 50
pounds. Use only UL listed junction boxes marked FOR FAN
SUPPORT. - Follow electrical codes and have electrical installation
performed by a qualified licensed electrician. - After marking electrical connections, spliced conductors should
be turned upward and pushed carefully up into the junction box. The
wires should be spread apart with the grounded conductor and the
equipment-grounding conductor on one side of the junction box. - The fan must be mounted with a minimum of 7 feet clearance from
the trailing edge of the blades to the floor. - Use only screws and washers provided with the junction box for
mounting to the junction box. - Do not use the reverse switch while the fan blades are in
motion. To prevent damage and ensure long use, turn off the fan and
stop the blades before reversing direction. - Do not place objects in the path of the blades.
- Exercise caution when working around or cleaning the fan. Use a
soft dry cloth to clean the fan body and blades. Do not use water
or detergent. - The electrical diagrams provided are for reference only. Light
kits that are not packaged with the fan must be UL listed and
suitable for use with this fan. Switches must be UL general use
switches. Refer to their separate instructions for proper
assembly. - Never bend the blade brackets/flanges for any reason.
V20220704
CFN-1101 Instruction Manual
Read Carefully Before Use Keep For Future Reference
TABLE OF CONTENTS
Introduction ··································································································· 1 Package Contents ·························································································· 2 Safety Information··························································································· 3 Preparation ··································································································· 4 Initial Installation ···························································································· 5 Circuit Connections ························································································ 6 Fan Motor Installation ····················································································· 7 Fan Blade Installation ······················································································ 7 Light Plate Installation ····················································································· 8 LED Light Kit Installation ·················································································· 8 Shade Installation ·························································································· 9 Color Temperature Adjustment ·········································································· 9 Remote Control Operation ·············································································· 10 Troubleshooting ····························································································11 Contact Information························································································11
INTRODUCTION
Before beginning installation of this product, read the package list on Page 2 and ensure all parts are present and display no defects. If any part is missing or damaged, contact customer service and do not attempt to install the product. Read all of the safety information on Page 3 before installation or use. Estimated assembly time: 120 minutes Additional tools required for assembly: Electrical tape, flathead & Phillips screwdriver, pliers, safety glasses, ladder, and wire strippers
Additional helpful tools: AC tester light, tape measure, wiring handbook, and wire cutters
1
PACKAGE CONTENTS
Fan Blades (×4) Mounting Bracket
Fan Motor Assembly
Light Plate
Glass Shade
LED Light Kit
MED LOW LI HI
STOP 2H 1H 4H R/F
Remote Control
Receiver
Metal Washers (×4)
Mounting Screws (×4)
Wiring Nuts (×6)
Blade Bolts (×14)
Plastic Washers (×14)
Anchor Bolts (×4) Spare Blade Arm Bolts (×2)
Gloves (×1)
Balance Kit
2
SAFETY INFORMATION
Warning!
1. To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker or fuse box before beginning.
2. All wiring must be in accordance with national and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
3. This fan is suitable for use with solid-state speed controls. 4. To reduce the risk of personal injury, use only the screws and washers provided with
the junction box for mounting to the junction box. Most junction boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, & PERSONAL INJURY, MOUNT FAN TO AN JUNCTION BOX MARKED “ACCEPTABLE FOR FAN SUPPORT”.
5. The junction box and support structure MUST be securely mounted and capable of reliably supporting a minimum of 50 pounds. Use only UL listed junction boxes marked “FOR FAN SUPPORT”.
6. After marking electrical connections, spliced conductors should be turned upward and pushed carefully up into junction box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the junction box.
7. The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
8. Do not use the reverse switch while the fan blades are in motion. To prevent damage and ensure long use, the fan must be turned off and the blades stopped before reversing direction.
9. Do not place objects in the path of the blades. 10. Exercise caution when working around or cleaning the fan. 11. Use a soft dry cloth to clean the fan body and blades. Do not use water or detergent. 12. The electrical diagrams provided herein are for reference only. Light kits that are not
packaged with the fan must be UL listed and suitable for use with this fan. Switches must be UL general use switches. Refer to their separate instructions for proper assembly.
NEVER BEND THE BLADE BRACKETS/FLANGES FOR ANY REASON.
3
PREPARATION
1. Turn off Your Power Begin installation by removing fuses or turning off circuit breakers to the wiring you will be using. Use your compatible UL listed junction box if you already have one installed.
Failure to disconnect the power supply prior to installation may result in serious injury or death.
Use only on flat ceilings
2. Choose Your Mounting Position
If you need to install a new UL listed junction box, secure it directly to your building’s structure using appropriate fasteners and materials. Do not use plastic boxes. The junction box and its supports must be able to support the MOVING weight of the fan (at least 50 lb.) and be rated for fan support.
Do not use on slanted surfaces
7 feet
30 inches
3. Choose a Suitable Location
Ensure the blades will be at least 30 inches from any obstruction and at least 7 feet above the floor. In locations without a ceiling joist, a hanger support bar may be required. Do not install in damp locations.
4
INITIAL INSTALLATION
Wood Ceiling
Mounting Bracket
Supply Wires Metal Washer
Concrete Ceiling
Anchor Bolt
Mounting Screw
1. Pass the supply wires from the junction box (not included) through the central hole of the mounting bracket.
2. Secure the bracket to the junction box with the provided fasteners. Use the mounting screws and metal washers on wood ceilings or the anchor bolts on reinforced concrete or similar ceilings.
5
CIRCUIT CONNECTIONS
Again, ensure that the power has been cut before working with the wiring. Use the wire nuts provided with your fan.
Ensure there are no loose wires or connections, and secure connectors with electrical tape.
Receiver
Mounting Bracket Steel Wire
1. Insert the receiver into the tray with the receiver facing the ceiling. For best performance, make sure the white antenna, on the end of the receiver, remains extended and not tangled with any of the electrical wires.
2. Connect the 5 colored wires from the remote receiver to the 5 identically colored lead wires from the fan motor. Secure each set with the provided wire nuts.
3. Connect the 2 colored wires from the remote receiver to the 2 identically colored lead wires from the fan motor. Secure each set with the provided wire nuts.
Junction Box
Black (live) Black (“AC IN L”)
Receiver Black (“to motor L”) Orange (for N) Red (for L)
Red (for L) Orange (for N)
White (neutral) Green or Bare Copper (ground) White (“AC IN N”)
Blue (light) White (neutral) Green (ground)
Blue (light) White (neutral)
Black (motor)
4. Connect the green or bare copper ground wire from the junction box to the ground wires from the ceiling fan. Separate the white and green connections from the black wire connections, which should be kept on opposite sides of the junction box.
6
FAN MOTOR INSTALLATION
Bracket Bolt
Motor Bolt
1. Remove the bolts pre-installed near the top of the fan motor assembly.
2. Connect the motor assembly to the mounting bracket by sliding its slots onto the built-in bolts of the bracket.
3. Secure the motor assembly by replacing and retightening the removed bolts.
FAN BLADE INSTALLATION
1. Fit a blade onto one blade arm underneath the fan motor, aligning their slots with each other.
2. Making sure the blade is straight, attach and tighten 3 plastic washers and blade bolts.
3. Repeat for the remaining blades.
Blade Arm
Plastic Washer Blade Bolt
Blade
7
LIGHT PLATE INSTALLATION
Wire Plug Light Plate
Bolt
1. Remove the bolts pre-installed underneath the fan motor assembly.
2. Feed the wire plug through the middle of the light plate.
3. Install the light plate onto the motor assembly and secure it by replacing and retightening the bolts.
LED LIGHT KIT INSTALLATION
Wire Plugs LED Light Kit
1. Connect the LED light kit to the light plate using its magnetic suction-cup bolts.
2. Connect the wire plugs of the LED light kit and the fan motor assembly together (blue to blue and white to white).
Magnetic Suction-Cup Bolt
8
SHADE INSTALLATION
Fit the glass shade onto the light plate and screw it into place. Ensure it is firmly connected to avoid loosening during use.
Light Plate Glass Shade
COLOR TEMPERATURE ADJUSTMENT
The LED light has 3 different color setting: Warm White (3000K), Daylight (4500K), and Cool White (6000K). To adjust the light settings, 1. Press LIGHT on the remote control to turn on the LED light. 2. Press LIGHT again to turn off the light. 3. Press LIGHT to turn on the light once more with the next color temperature in order. Repeat these steps to toggle among 3 color temperatures.
9
REMOTE CONTROL OPERATION
Install the remote control holder onto any wall or suitable flat surface using the two steel screws.
Key
Function
LOW Starts the fan at low speed
MED Starts the fan at medium speed
HI Starts the fan at high speed
STOP Stops the fan
LIGHT Turns the light on or off
1H Runs the fan for 1 hour and then turns it off
2H Runs the fan for 2 hours and then turns it off
4H Runs the fan for 4 hours and then turns it off
R/F Reverses the fan’s direction
DO NOT press R/F while the fan is turning. Wait for it to stop completely before changing the direction of its rotation.
This remote operates with a range of 30 feet (10 m). It uses 2 1.5V AAA batteries (not included). If the remote will not be used for a prolonged period, it is recommended to remove the batteries for better service life.
10
TROUBLESHOOTING
Potential Problems Fan blades don’t rotate
Fan is too noisy
Fan wobbles during use
Common Solutions
Check fuses and/or circuit breakers and reset if needed.
Cut off power to the fan and check its internal electrical connections.
Replace the remote control’s batteries.
Check that the fan cover is correctly placed and no fasteners interfere with the movement of the blades.
Contact customer service to replace a faulty remote control.
Check that all fasteners are well tightened.
Ensure the canopy housing has a short distance between itself and the ceiling.
Upon initial installation, allow 24 hours of use for the machine to break itself in.
Cut off power to the fan and check that the wire nut connections are not rubbing against one another or the inner housing.
If you have installed a solid-state variable-speed control, cut off power to the fan and disconnect this control from the device. See if using the remote resolves the problem, which can be caused by erratic signals from such controls.
Check that all fasteners are well tightened.
Use the provided blade balancing kit to adjust the blades if their tips are found to be an unequal distance from the ceiling while well fastened.
Exchange the position of the various blades.
Again, do not bend the blades during any of these procedures.
CONTACT US
Thank you for choosing our products! If you have any questions or comments, contact us at [email protected] and we’ll resolve your issue ASAP!
For a .pdf copy of the latest version of these instructions, use the appropriate app on your smartphone to scan the QR code to the right.
11
CFN-1101-NI Rev. 4 Jul. 2022