PA-200-AM-BL 3-Speed Low Amp Centrifugal Air Mover with Daisy Chain Capability
Product Information
The 3-Speed Low Amp Centrifugal Air Mover with Daisy Chain
Capability is a powerful air mover designed to quickly and
efficiently move air in various environments. It has a compact size
and lightweight design, making it easy to transport and use in
different locations. The air mover features a 1/5HP motor and
operates at 115V with a power cycle of 60Hz. It has a maximum air
volume of 800CFM and draws 2.1AMPS of power. The unit weighs 11 lbs
and has dimensions of 13×12.2×11 inches. It comes with a 10ft/14AWG
cord for convenient use.
Product Usage Instructions
Before using the air mover, please read and understand all
warnings and instructions provided in the owner’s manual.
- Ensure that there is power supply to the unit. Plug the air
mover into a power outlet and check the circuit breaker. - Make sure the switch is in the ON position.
- If the unit still does not run, the switch may be faulty.
Replace the switch with a new one. - If there is no power or the motor does not run, check for any
faulty or broken cords or motor wires. Perform a continuity check
using a volt/amp meter and repair or replace any damaged
wires.
If the air mover is running but making a loud scraping
noise:
- The unit may have been severely jolted, causing the blower
wheel to rub against the housing. Remove the motor and replace
damaged motor mounts. - If the housing is deformed due to severe jolts, replace the
blower wheel.
If the air mover vibrates excessively:
- A severe jolt may have bent the motor shaft, causing the unit
to be out of balance. Remove and replace the motor. - If the air mover blade is damaged, replace it if
necessary. - If there is dirt build-up on one side of the air mover blade,
clean the blade.
If the blower wheel does not turn:
- The motor bearings may be failing or the motor has developed an
internal electrical fault. Replace the motor. - Check if the intake grill and/or exhaust grill is obstructed.
Remove any obstructions. - If there is excessive duct length, reduce it to the recommended
maximum.
For assembly and replacement of parts, refer to page 3 of the
user manual for the part numbers and descriptions. Follow the
instructions provided to assemble or replace the necessary
components.
Puraero offers a 1-year warranty on parts and labor for this air
mover. Please refer to page 4 of the user manual for detailed
warranty policy information.
3-SPEED LOW AMP CENTRIFUGAL AIR MOVER WITH DAISY CHAIN CAPABILITY
CM
C
US
READ AND SAVE THESE INSTRUCTIONS
OWNERS MANUAL
READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USING THIS AIR MOVER!
VOLTS POWER CYCLE MAX AIR VOLUME AMPS WEIGHT SIZE L/W/H SPEED CORD LENGTH
115V 1/5HP 60Hz 800CFM 2.1AMPS 11 Ibs 13″x12.2″x11″ 3 SPEEDS 10ft/14AWG
Page 2
Problem
Cause
Solution
Unit will not run.
1. No power to nuit. 2. Switch not on. 3. Switch is faulty. 4. Faulty/broken cord or motor wire
1. Plug unit in. Check circuit breaker. 2. Place in “ON” position. 3. Replace switch. 4. Perform continuity check, using volt/amp meter. Repair/replace faulty broken wire.
Unit runs but air mover makes loud scraping noise.
1. Unit has been severely jolted causing blower wheel to rub against housing. 2. Unit has been severely jolted causing housing to deform.
1. Remove motor and replace damaged motor mounts. 2. Replace blower wheel.
Unit runs but vibrates excessively.
1. Severe jolt has bent motor shaft causing unit to be out of balance. 2. Air mover blade damaged. 3. Dirt build up on one side of air mover blade.
1. Remove and replace motor. 2. Replace blade if necessary. 3. Clean air mover blade.
Unit runs but blower wheel does not turn.
1. Motor bearings are failing or motor has developed an internal electrical fault. 2. Intake grill and/or exhaust grill is obstructed. 3. Excessive duct length.
1. Replace motor. 2. Remove obstruction. 3. Reduce duct length to recommended maximum
Page 3
PA-330-AM MOVER ASSEMBLY
5
1
1
2
4
9
13
8
1
11
2
6
14
3 7
10
1
12 1
ITEM
PART
NUMBER NUMBER
DESCRIPTION
1
200-01 SCREW
2
200-02 SWITCH ASSEMBLY
3
200-03 SWITCH KNOB
4
200-04 STRAIN RELIEF CAP
5
200-05 POWER CORD
6
200-06 NUT
7
200-07 FRONT GUARD
8
200-08 MOTOR
QTY
21 1 1 1 1 1 1 1
ITEM
PART
NUMBER NUMBER
DESCRIPTION
9
200-09 HOUSING CASE
10
200-10 RUBBER FEET
11
200-11 WHEEL FAN
12
200-12 KICKSTAND
13
200-13 GFCI PLUG
14
200-14 CIRCUIT BREAKER
15
16
QTY
1 6 1 1 1 1
PURAERO’S WARRANTY POLICY
1-Year Warranty Subject to the conditions stated below. PURAERO offers a limited warranty on parts and labor on the following equipment, parts and accessories to be free from defects in material and workmanship for a period of one year to the original purchaser.
Wear items exempt from warranty consideration include but may not be limited to: power cords, transport wheels, castors, handle grips, filters, screens. Subject to the conditions and exceptions stated in this warranty. PURAERO warrants the PURAERO products to be free from defects in material and workmanship. Under normal use and service. for the periods listed under the warranty policy to the original purchaser. At any time during the warranty period, original owner will be liable for transportation costs to repair facility. PURAERO will furnish replacement parts for the PURAERO products to the original purchaser. Such parts will be fumished and charged including transportation costs, to the original owner. Replacement parts that have become defective through wear or abuse are not included in this warranty. This warranty does not apply to damage or defect caused by accident, misuse, negligence, fire or to any PURAERO product which has been serviced or repaired by other than an authorized PURAERO Service Distributor or PURAERO factory personnel. This warranty is void if products are used for any purpose other than that which was intended. There are no other warranties expressed or implied. In no event shall PURAERO be liable for incidental or consequential damages or any damage to person or property.(Please note some states do not allow the exclusion or limitations for incidental and consequential damages.)
Page 4