Cotek Sd3500 Series 3500w Pure Sine Wave Owner's Manual

SD3500 Series 3500W Pure Sine Wave

Product Information

  • Model: SD3500 series
  • Rating Power: 3500 ~ 4500VA, 4500 ~ 6000VA, >6000VA
  • Waveform: Pure Sine Wave
  • Efficiency: 90% – 91%
  • Total Harmonic Distortion (THD): < 3%
  • Input Protection: Reverse Polarity (Fuse), Under Voltage, Over
    Voltage
  • Output Protection: Short Circuit, Overload, Over Temperature,
    Over Voltage
  • DC Input Voltage Range: 10.0VDC – 64.0VDC
  • AC Input Frequency: 50 / 60 Hz
  • Transfer Switch: Standard ATS (8~10ms), Optional STS module
    (< 4ms)
  • LED Indicator: Green LED (Solid, Slow Blink, Intermittent
    Blink), Orange LED (Fast Blink, Slow Blink), Red LED (Intermittent
    Blink, Fast Blink, Slow Blink)
  • Safety & EMC Standards: E-Mark, Certified UL 458, Certified
    EN62368-1, Certified FCC Class B, Certified EN 55014-1, EN 55014-2,
    EN 61000-3-2, 3-3, EN61204-3; EN 61000-6-1, -6-2, -6-3, -6-4 EN
    62368-1, Certified CISPR 25; ISO 7637-2
  • Control & Signal: Input voltage level, faulty status, CR-6,
    CR-8, and CR-10
  • Dimension (WxHxD): 283x128x496 mm / 11.14×5.04×19.53 inch
  • Weight: 10 kg; 2pcs / 21kg / 3.19cuft
  • Cooling: Load & Thermal control fan
  • Communication Port: RS-232 (RJ-11 type connector)

Product Usage Instructions

  1. Connect the DC input to the appropriate power source within the
    voltage range specified (10.0VDC – 64.0VDC).
  2. Connect the AC input to the power source within the specified
    frequency range (50 / 60 Hz).
  3. Ensure the input protection is in place, including reverse
    polarity fuse, under voltage protection, and over voltage
    protection.
  4. Connect the desired load to the output terminals of the
    device.
  5. Ensure the output protection is in place, including short
    circuit protection, overload protection, over temperature
    protection, and over voltage protection.
  6. Use the LED indicators to monitor the status of the device.
    Green LED indicates normal operation, orange LED indicates a
    warning or fault, and red LED indicates an error or critical
    fault.
  7. If remote control is desired, connect the remote control device
    using the RS-232 communication port.
  8. Monitor the efficiency of the device, which is typically around
    90% – 91%.
  9. Ensure that the total harmonic distortion (THD) is below 3%
    under specified conditions.
  10. Refer to the safety and EMC standards to ensure compliance with
    regulations.
  11. Refer to the control and signal section for information on
    input voltage level, faulty status, and compatibility with specific
    remote control models (CR-6, CR-8, and CR-10).
  12. Ensure proper cooling of the device by maintaining adequate air
    circulation and monitoring the load and thermal control fan.

3500W Pure Sine Wave
Features:
Parallel redundancy design for power expansion Multiple industrial applications that create 13W / 34W power systems Automatic master mechanism to eliminate single point failure and optimize reliability Built-in ATS and AC circuit breaker Optional STS module, transfer time less 4ms. RS-232 communication Input & output fully isolation Output voltage / power saving mode selectable by DIP switch or remote control (CR-10)
Input Protection: Reverse Polarity (Fuse) / Under Voltage / Over Voltage Output Protection: Short Circuit / Overload / Over Temperature / Over Voltage

SD3500 series

MODEL

SD3500-112 SD3500-124 SD3500-148 SD3500-212 SD3500-224 SD3500-248

Rating Power

3500VA (de-rating after 35°C, refer to de-rating curve for 12V) (de-rating after 40°C, refer to de-rating curve for 24V and 48V)

Output

Output Power (Max. 3 min.) Peak Power (Max. 3 sec.) Surge Power (Max. 0.2 sec.) Waveform Efficiency (Max.) Output Voltage (@rated VDC) Output Frequency
Total Harmonic Distortion (THD)

3500 ~ 4500VA

4500 ~ 6000VA

>6000VA

Pure Sine Wave

90%

90%

91%

90%

91%

91%

100 / 110 / 115 / 120VAC ±3%

200 / 220 / 230 / 240VAC ±3%

50 / 60Hz ±0.1%

< 3% @ under condition : greater than 1.15 times < 3% @ under condition : greater than 1.15 times

of the rated VDC, 110V / linear load)

of the rated VDC, 230V / linear load)

DC Input
AC Input
Protection Environment

DC Voltage Voltage Range No load Power Consumption On Mode @ Save Mode On Mode @ No Load Mode Fuse AC Range Frequency Selectable Synchronous Frequency Circuit Breaker
Transfer Switch ***
BAT.Low Alarm ±3% BAT.Low Shut-down ±3% BAT.Low Restart ±3% BAT.High Alarm ±3% BAT.High Shut-down ±3% BAT.High Restart ±3% Input Protection Output Protection Working Temp. Storage Temp. Relative Humidity Safety Standards

Safety & EMC EMC Standards

E-Mark

Control & Signal

LED Indicator Remote control

Dimension (WxHxD)

Others

Parking Cooling

Communication Port

12VDC

24VDC

48VDC

12VDC

24VDC

48VDC

10.0~16.0VDC 20.0~32.0VDC 40.0~64.0VDC 10.0~16.0VDC 20.0~32.0VDC 40.0~64.0VDC

@12VDC

@24VDC

@48VDC

@12VDC

@24VDC

@48VDC

1.4A < 2.9A

0.5A < 1.4A

0.5A < 0.8A

1.4A < 3.6A

0.5A < 1.8A

0.5A < 1A

40Ax12

20Ax12

20Ax6

40Ax12

20Ax12

20Ax6

100 / 110 / 115 / 120VAC±25%, recover±12.5% 200 / 220 / 230 / 240VAC±25%, recover±12.5%

50 / 60 Hz

47 – 57 / 53 – 63 Hz

35A

20A

Standard ATS : Inverter to utility AC:8~10ms.; Utility AC to inverter: 16~50ms.

Optional STS module : Single < 4ms; N+1&1P3W&3P4W < 6ms

10.5VDC

21.0VDC

42.0VDC

10.5VDC

21.0VDC

42.0VDC

10.0VDC

20.0VDC

40.0VDC

10.0VDC

20.0VDC

40.0VDC

12.5VDC

25.0VDC

50.0VDC

12.5VDC

25.0VDC

50.0VDC

15.5VDC

31.0VDC

62.0VDC

15.5VDC

31.0VDC

62.0VDC

16.0VDC

32.0VDC

64.0VDC

16.0VDC

32.0VDC

64.0VDC

15.0VDC

30.0VDC

60.0VDC

15.0VDC

30.0VDC

60.0VDC

Reverse Polarity (Fuse) / Under Voltage / Over Voltage Protection / AC over current (Breaker)

Short Circuit / Overload / Over Temperature / Over Voltage

-20 ~ +60°C; refer to SD3500 power de-rating curve

-40 ~ +70°C

Max. 90%, non-condersing

**Certified UL 458 (UL only for hardwire)

Certified EN62368-1

Certified FCC Class B

**Certified EN 55014-1, EN 55014-2, EN 61000-3-2, 3-3, EN61204-3; EN 61000-6-1, -6-2, -6-3, -6-4 EN 62368-1

­

Certified CISPR 25; ISO 7637-2

Input voltage level, faulty status

CR-6, CR-8 and CR-10

283x128x496 mm / 11.14×5.04×19.53 inch

10 kg; 2pcs / 21kg / 3.19cuft

Load & Thermal control fan

RS-232 (RJ-11 type connector)

Note

*UL-458 only support 112 and 124 model. **EN55014-1, EN55014-2 Class B : output cable less than 2 meters. ***Please refer to Transfer – Time Table.

REV. A9 22/09/20
1

3500W Pure Sine Wave

LED Status:
Green LED Solid
Slow Blink Intermittent Blink
Orange LED Fast Blink Slow Blink Red LED Intermittent Blink Fast Blink Slow Blink
Solid Intermittent Blink Intermittent Blink

LED Signal LED Signal LED Signal

Status
Power OK Power Saving
Bypass
Status
OVP UVP
Status
OTP OVP- Shut-down UVP- Shut-down
OLP Fan Failure Component Failure

SD3500 series

Output Socket:

UL458

United Kingdom

Universal

De-rating Curve:

13~16V 12V 11V 10V

REV. A9 22/09/20
1

Transfer Time :

3500W Pure Sine Wave

Transfer-Time Table

ModeTransfer Switch

ATS

STS

Haphazard

Frequency is synchronized : <4ms Inverter to utility AC : 8 ~ 10ms.; Frequency is not synchronized : Utility AC to inverter : 16 ~ 50ms. Inverter to utility AC : <4ms.;
Utility AC to inverter : 16 ~ 50ms.

Normal

Inverter to utility AC : 8 ~ 10ms.; Utility AC to inverter : 16 ~ 25ms.

<4ms

Exacting

Inverter to utility AC : 8 ~ 10ms.; Inverter to utility AC : <4ms.; Utility AC to inverter : 16 ~ 50ms. Utility AC to inverter : 16 ~ 50ms.

Online

Inverter to utility AC : 8 ~ 10ms.; Utility AC to inverter : 16 ~ 25ms.

<4ms

Mechanical Drawings:
125.6 [4.94]

496 [19.53] 240.0 [9.45]

SD3500 series
Unit : mm [inch]

268.6 [10.57] 283 [11.14]

128 [5.04]

8.5 [0.33]

REV. A9 22/09/20