IT-N6900 Programmable DC Power Supply
Product Information
Product Name: IT-N6900 Programmable DC Power
Supply
Features:
- CC, CV priority
- Suitable for a variety of DUT’s
- Remote Sense function
- Supports OVP, UVP, OCP, OPP, OTP, Foldback protection
function - Built-in USB/LAN/Digital IO communication interface, optional
GPIB/RS232/analog IO - Supports SCPI, LabVIEW programming
- Trend analysis – monitor the voltage, current, and power of the
DUT in real-time
Applications:
- Automotive Electronics
- Motor
- Battery
- Communication
- Consuming Electronics
- Production Line
Product Usage Instructions
Data Logging Function (Trend Analysis)
The IT-N6900 supports trend analysis function, allowing users to
observe voltage, current, and power online for a long time. To use
this feature:
- Connect the IT-N6900 to the DUT using the appropriate
cables. - Turn on the power supply.
- On the IT-N6900 interface, select the trend analysis
function. - Observe the voltage, current, and power readings on the HD
screen in real-time. - To save test data, insert a U disk into the USB port and
configure the data recording interval.
List Programming
The IT-N6900 has a LIST programming function that allows users
to create output change sequences. To use this feature:
- Access the IT-N6900 programming interface.
- Create a sequence file by editing the steps for voltage,
current, time, and cycle. - Save the sequence file.
- Select the desired sequence file for output.
- The IT-N6900 will output the specified sequence according to
the programmed steps.
CC&CV Priority
The IT-N6900 supports CC and CV priority modes. To select the
desired mode:
- Access the IT-N6900 settings menu.
- Select either CC or CV priority mode.
- In CC priority mode, there will be no voltage overshoot.
- In CV priority mode, there will be no current priority.
Foldback Protection
The IT-N6900 provides multiple protection functions, including
OVP/UVP/OCP/OPP/OTP/Foldback. To configure Foldback protection:
- Access the IT-N6900 settings menu.
- Enable the Foldback protection function.
- Set the working mode and protection delay time.
- When the power supply CV/CC is switched, the output will be
turned off to protect sensitive DUTs from voltage and current
overshoot.
IT-N6900
Programmable DC Power Supply
IT-N6900 Programmable DC Power Supply
IT-N6900 DC power supply has 60V and 150V, 850W and 1500W output. It features as black panel and HD screen, low ripple and noise. It can provide stable and pure DC power, two current ranges, up to 1µA current resolution. It has CC and CV priority settings, new Foldback protection. It is well used for the test of DC-DC, semiconductor lasers, automotive electronics, communication electronics, motors, PV modules and so on. IT-N6900 series supports SCPI and LabVIEW drivers, built-in USB/LAN/digital IO communication interface, optional GPIB/RS232/analog IO, suitable for remote control and system integration, and can be used in R&D, production lines, univeristies, etc.
FEATURE
4.3” HD LCD Voltage: 60V, 150V Power: 850W, 1500W, wide range output Two current ranges, 1µA current resolution Lower ripple and noise Using a new type of transformer, lighter, higher efficiency and stability Faster voltage rise and fall
With CC, CV priority, suitable for a variety of DUT’s Remote Sense function Support OVP, UVP, OCP, OPP, OTP, F oldback protection function Built-in USB/LAN/Digital IO communication interface, optional GPIB/RS232/analog IO Support SCPI, LabVIEW programming Trend analysis,monitor the voltage, current and power of the DUT in time
Applications
Automotive Electronics
Motor
Battery
Communication
Consuming Electronics
Production Line
Model IT-N6952 IT-N6962 IT-N6953 IT-N6963 IT-E177 IT-E176
Voltage
Current
60V
25A
60V
25A
150V
10A
150V
10A
RS232& analog
GPIB
*1 The power output is 850W under 110Vac input
Power 850W 1500W*1 850W 1500W*1 Optional Optional
01 IT-N6900 Programmable DC Power Supply
Semiconductor LAN USB Digital IO Optional Interface
Power Sense Output
Your Power Testing Solution
IT-N6900 Programmable DC Power Supply
Data Logging Function (Trend Analysis)
IT-N6900 supports trend analysis function, allowing end users to observe voltage, current and power online for a long time. Users can save test data in U disk, and the time interval of data recording can be set, which is especially suitable for long-term aging test of production lines or R&D laboratories. HD screen with graphic display, users can observe the abnormal situation of the test in real time.
List programming
V
The LIST programming function of IT-N6900 can provide a maximum of 100 steps of sequence output, and a total of 10 sequence files can be edited. The user can generate various output change sequences by editing the steps such as voltage, current, time and whether to cycle the steps of each single step. The parameters include time units.
CC&CV priority
T1 T2 T3 T4 T1 T2 T3 ……
T
IT-N6900 has CC/CV priority function, which is suitable for complex applications with high speed or no overshoot test requirements. In CV priority mode, you can get faster voltage rising. In CC priority mode, the output current has no overshoot, which can be used to test the DUT of constant current operating characteristics. It is good for applications such as laser testing, integrated circuit testing, charge and discharge testing, power transient simulation and characterization of automotive electronics, etc.
CV priority no voltage overshoot
CC priority no current priority
Foldback
IT-N6900 supports multiple protection functions such as OVP/UVP/OCP/OPP/OTP/Foldback. The Foldback protection function is mainly used to turn off the output when the power supply CV/CC is switched, so as to protect the DUTs which are sensitive to voltage and current overshoot. You can set the working mode and the protection delay time. If the current working mode is changed, the protection will be triggered when the time is up and the output will be turned off.
02 www.itechate.com
Parameter
Rated values
Line regulation ±c%of Output+Offset Load regulation ±c%of Output+Offset
Setup resolution
Readback resolution
Setup accuracy
Readback resolution
Ripplec20Hz~20MHz Ripplec20Hz~20MHz Setup temperature coefficient ±c% of Output+Offset/¥
Rising time (no load) ±c% of Output+Offset/¥ Rising time (no load) Rising time (full load) Falling time (no load) Falling time (full load) Dynamic response*5
AC input
Efficiency Sense Programming response Power factor Max.input current Max. input apparent power Storage temperature Protection Isolation(output to ground) Isolation(input to ground) Working temperature Dimension(mm) Weight(net)
Voltage Current Power Voltage Current Voltage Current Voltage Current Voltage
Current
Voltage Current Voltage
Current
Peak value Voltage(RMS) Current(RMS)
Voltage Current Voltage
Current
Voltage Voltage Voltage Voltage Voltage Voltage Frequency
IT-N6962
IT-N6963
0~60V
0~150V
0~25A
0~10A
0~1500W*6 0.01%+6mV 0.02%+5mA 0.01%+6mV*1 0.02%+5mA
1mV
1mA
1mV
1mA 1µA20mA*2 0.03%+12mV*3 0.1%+25mA 0.03%+12mV 0.1%+25mA 0.05%+20uA (20mA)*4
0~1500W*6 0.01%+15mV 0.02%+2mA 0.01%+15mV*1 0.02%+2mA 1mV100V10mV100V
1mA 1mV100V10mV100V
1mA 1µA20mA*2 0.03%+30mV*3 0.1%+10mA 0.03%+30mV 0.1%+10mA 0.05%+20uA (20mA)*4
15mVp-pTypical 2mVrmsTypical
9mArms
30mVp-pTypical 4mVrmsTypical
7mArms
0.002% + 0.4mV
0.002% + 1mV
0.005% + 1.5mA
0.005% + 0.6mA
0.002% + 0.4mV
0.002% + 1mV
0.005% + 1.5mA
0.005% + 1µA*4 20ms 10%-90% 30ms 10%-90% 150ms 90%-10% 15ms 90%-10% 100µs 50%-100% load back to 150mV
0.005% + 0.6mA
0.005% + 1µA*4 30ms 10%-90% 30ms 10%-90% 150ms 90%-10% 15ms 90%-10% 200µs 50%-100% load back to 150mV
100V-240V
50/60Hz
75%Typical 2.5VPer each lead
5ms
0.98
11A
2100VA
-1070
OVP/UVP/OCP/UCP/OTP/OPP/Foldback
240V
1500Vac
040
255mm(W)×108.2mm(H)×529.5mm(D)
7.6kg
*1 Measured with sense wiring *2 When the current measurement range is 20mA, the capacitive load of the power supply cannot exceed 47µF *3 Voltage setting accuracy and measurement accuracy are measured under sense wiring *4 The accuracy of small range current (20mA range) is measured in the state of power supply output CV *5 Test under frequency 100Hz *6 99Vac-121Vac max. output 850W *All specifications are subject to change without notice.
ITECH ELECTRONICS
Web: www.itechate.com E-mail: [email protected]








![Itech Power Meter [it9121, It9121h, It9121c, It9121e] User Manual Itech Power Meter [it9121, It9121h, It9121c, It9121e] User Manual](https://static-data1.manualsee.com/1/img/72/17006/2020/12/iTech-Power-meter.jpg)






