PCE-VE Series Industrial Borescope
Product Information: Product Name: PCE-VE 400N4 / PCE-VE
800N4 / PCE-VE 900N4 Industrial Borescope Last Change: 13 January
2021 v1.0 Specifications: – Cable / head diameter: 2.8 mm (PCE-VE
800N4), 4 mm (PCE-VE 400N4), 2 mm (PCE-VE 900N4) – Camera head
movement direction: 4-way – Camera head length: 8 mm (PCE-VE
800N4), 18 mm (PCE-VE 400N4), 7 mm (PCE-VE 900N4) – Bending radius:
7 mm (PCE-VE 800N4), 8 mm (PCE-VE 400N4), 6 mm (PCE-VE 900N4) –
Camera head material: Titanium alloy – Camera lens material: Glass
– Viewing angle: 5 … 50 mm – Viewing direction: 10 … 100 mm –
Focus area: 3 … 30 mm – Image sensor: 1/18 colour (PCE-VE 800N4),
1/9 colour (PCE-VE 400N4, PCE-VE 900N4) – Resolution: 160000 pixels
(PCE-VE 800N4), 1000000 pixels (PCE-VE 400N4), 160000 pixels
(PCE-VE 900N4) – Frame rate: 30 Hz – Length borescope cable: 1.5 m
(PCE-VE 400N4), 1.2 m (PCE-VE 900N4) – Material borescope cable:
Tungsten – Protection class borescope cable: IP58 (PCE-VE 400N4),
IP67 (PCE-VE 900N4) – Operating conditions: SDHC memory card up to
64 GB – Power supply: Li-Ion battery 3350 mAh, Mains adaptor 5 V –
Dimensions: 33.5 x 14.5 x 8 cm – Weight: Approx. 700 g Product
Usage Instructions: 1. Safety Notes: – Before using the device
for the first time, read the user manual carefully and completely.
– The device should only be used by qualified personnel and
repaired by PCE Instruments personnel. – Non-observance of the
manual may result in damage or injuries, which are excluded from
the liability and warranty. 2. Rechargeable Batteries: 6.1 Remove
batteries: – Follow the instructions provided in the user manual to
remove the rechargeable batteries. 6.2 External charging: – Connect
the external charger to the device as per the instructions provided
in the user manual. 3. Contact: – For any questions or assistance,
contact PCE Instruments using the contact details provided at the
end of the user manual. 4. Disposal: – Follow the proper disposal
methods as per local regulations. 5. Function Modes: – The device
has four different function modes: Recording, Playback, Toolbar,
and Menu. The keys on the device have different functions depending
on the mode you are in. 6. Delivery Scope: The package includes the
following items: – Borescope PCE-VE 800N4 / PCE-VE 400N4 / PCE-VE
900N4 – Mains adaptor incl. charger – Card reader – Memory card –
Li-Ion battery set (2x) – HDMI cable – Cleaning set – User manual –
Carrying case 7. Device Description: The device consists of the
following components: 1. Display 2. Image memory 3. Charging
indicator 4. Operating display 5. Freeze key (freeze image) 6. DOWN
key 7. ON/OFF key 8. UP key 9. Menu key 10. OK key 11. Borescope
cable 12. Micro USB socket (data transfer to PC) 13. HDMI socket
(e.g., for external monitor) 14. SD card slot 15. Charging socket
DC in 16. Reset key 17. Headphone jack 18. Video recording key 19.
Illumination key 20. Image capture key 21. Display brightness Note:
Refer to the user manual for detailed instructions on using each
component and its corresponding functions. Please refer to the
complete user manual for detailed instructions on using the PCE-VE
400N4 / PCE-VE 800N4 / PCE-VE 900N4 Industrial Borescope, including
setup, operation, maintenance, and troubleshooting information.
Englis h
User Manual
PCE-VE 400N4 / PCE-VE 800N4 / PCE-VE 900N4 Industrial Borescope
User manuals in various languages (français, italiano, español, português, nederlands, türk, polski,
, ) can be found by using our product search on: www.pce-instruments.com
Last change: 13 January 2021 v1.0
© PCE Instruments
Contents 1 Safety notes ………………………………………………………………………………. 1 2 Specifications ……………………………………………………………………………. 2 3 Delivery scope …………………………………………………………………………… 2 4 Device description …………………………………………………………………….. 3 5 Function modes ………………………………………………………………………… 4
5.1 Key assignment…………………………………………………………………………………………………. 4 5.2 Display icons…………………………………………………………………………………………………….. 5 5.3 Switch the instrument on/off ………………………………………………………………………………… 5 5.4 Menu……………………………………………………………………………………………………………….. 5
6 Rechargeable batteries ……………………………………………………………… 6
6.1 Remove batteries ………………………………………………………………………………………………. 6 6.2 External charging ………………………………………………………………………………………………. 6
7 Contact……………………………………………………………………………………. 7 8 Disposal ……………………………………………………………………………………. 7
© PCE Instruments
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
· The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
· The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
· Do not expose the device to shocks or strong vibrations. · The case should only be opened by qualified PCE Instruments personnel. · Never use the instrument when your hands are wet. · You must not make any technical changes to the device. · The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents. · The device must only be used with accessories from PCE Instruments or equivalent. · Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device. · Do not use the instrument in explosive atmospheres. · The measurement range as stated in the specifications must not be exceeded under
any circumstances. · Non-observance of the safety notes can cause damage to the device and injuries to
the user. We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.
© PCE Instruments 1
2 Specifications
Technical data of the endoscope PCE-VE 800N4
Cable / head diameter
Camera head movement direction Camera head length Bending radius
2.8 mm
4-way 8 mm 7 mm
Camera head material
Titanium alloy
PCE-VE 400N4 4 mm
18 mm 8 mm
Camera lens material
Glass
Viewing angle
80 °
90 °
Viewing direction
0 °
Focus area
5 … 50 mm
10 … 100 mm
Image sensor
1/18″ colour
1/9″ colour
Resolution Frame rate Length borescope cable Material borescope cable Protection class borescope cable
Operating conditions
Display Interface Video output Memory
160000 pixels 30 Hz
Tungsten
1000000 pixels 1.5 m
IP58
IP67
Main unit: 0 … 45 °C / 15 … 90 % RH Cable: 0 … 60 °C 5″ 16:9 LCD Micro USB HDMI
SDHC memory card up to 64 GB
Power supply
Li-Ion battery 3350 mAh Mains adaptor 5 V
Dimensions Weight
33.5 x 14.5 x 8 cm approx. 700 g
PCE-VE 900N4 2 mm
7 mm 6 mm
80 °
3 … 30 mm 1/18″ colour 160000 pixels
1.2 m IP58
3 Delivery scope
1x borescope PCE-VE 800N4 / PCE-VE 400N4 / PCE-VE 900N4 1x mains adaptor incl. charger 1x card reader 1x memory card 2x Li-Ion battery set 1x HDMI cable 1x cleaning set 1x user manual 1x carrying case
© PCE Instruments 2
4 Device description
1. Display 2. Image memory 3. Charging indicator 4. Operating display 5. Freeze key (freeze image) 6. DOWN key 7. ON/OFF key 8. UP key 9. Menu key 10. OK key 11. Borescope cable 12. Micro USB socket (data transfer to PC) 13. HDMI socket (e. g. for external monitor) 14. SD card slot 15. Charging socket DC in 16. Reset key 17. Headphone jack 18. Video recording key 19. Illumination key 20. Image capture key 21. Display brightness
© PCE Instruments 3
5 Function modes
The keys have different functions depending on which mode you are in. These are the 4 different modes you can be in:
Mode Recording Playback Toolbar Menu
Function
Display shows camera image and optional setting options.
Images and videos on the microSD card are displayed.
The toolbar is visible at the top of the screen in recording mode. Settings such as brightness, zoom, etc. can be changed here.
Contains all system settings.
5.1 Key assignment
Key
Recording
Playback
Toolbar
Menu
Up/Down
Switch to previous / next image
Change the
Previous / next
setting or option menu item
Menu Ok Play
Freeze Off/On LED Video
Open menu
Open menu
Open menu
–
Move to the next setting in the toolbar
Open record memory
Freeze image
Switch off the instrument
Adjust the brightness of the LED
Start/stop video recording
Confirm deletion
Back to recording mode Delete record Switch off the instrument
–
–
Change in the settings
Open record memory
Freeze image
Switch off the instrument Adjust the brightness of the LED Start/stop video recording
Confirm selection
Back to recording mode Switch off the instrument
–
Image
Image recording –
Image Brightness brightness
–
Image recording –
Image brightness
–
Note: “-” means no function of the key in the respective function mode.
© PCE Instruments 4
5.2 Display icons Icon Brightness (5 levels)
Description
Exposure (-2, -1, 0, +1, +2) Image rotation 90 Colour filter (black and white, negative) White balance Freeze image Full screen Zoom Borescope is ready for image recording
Borescope records a video
5.3 Switch the instrument on/off Press and hold the off/on key for about 2 seconds to switch the instrument on or off.
5.4 Menu In recording mode, press the menu key once to open the menu. Use the up/down keys to select the desired setting parameter. You can close the menu with the freeze key. The menu contains the following system settings:
5.4.1 Language Here you can choose between German, English, Chinese and Japanese. Confirm your setting with the OK key.
5.4.2 Date/time Setting the date and time and the display format – Press the freeze key to go to the next setting option. Confirm your entry with the Ok key.
5.4.3 Save power Here you can set when the instrument should switch off automatically. You can select Off, 1 min, 3 min and 5 min. Confirm your setting with the OK key.
5.4.4 Print date You can set whether only the date, date and time or nothing is saved on the image. Confirm your setting with the OK key.
© PCE Instruments 5
5.4.5 Format Here you can format the microSD card in the borescope. All data on the card will be irrevocably deleted. Confirm your setting with the OK key. 5.4.6 Reset everything To reset the instruments to factory settings, select “Yes” in this menu item. Selecting “No” takes you back to the menu. If the instrument can no longer be operated, you can also use the reset key on the side of the instrument. 5.4.7 FW update If a firmware update is available for the instrument, it can be installed via this menu item.
6 Rechargeable batteries
The batteries can be charged within the unit with the supplied mains adaptor, as well as with the external charger when removed. 6.1 Remove batteries To remove the batteries, proceed as follows:
1. Loosen the screw of the bottom cover of the instrument. 2. Pull the battery unit out of the borescope. 3. Open the battery compartment by pulling off the cover. 4. Replace the batteries and reassemble the unit in reverse order. Make sure that the
polarity is correct!
6.2 External charging After removing the batteries from the instrument, place them in the charger. Make sure that the polarity is correct! As soon as the batteries are fully charged, you can re-insert them into the instrument. Note: The batteries need approx. 8 hours to fully charge.
© PCE Instruments 6
7 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
8 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.
© PCE Instruments 7
PCE Instruments contact information
Germany
PCE Deutschland GmbH Im Langel 4 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 [email protected] www.pce-instruments.com/deutsch
United Kingdom
PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 [email protected] www.pce-instruments.com/english
The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 [email protected] www.pce-instruments.com/dutch
United States of America
PCE Americas Inc. 1201 Jupiter Park Drive, Suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 [email protected] www.pce-instruments.com/us
France
PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 [email protected] www.pce-instruments.com/french
Italy
PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 [email protected] www.pce-instruments.com/italiano
China
PCE (Beijing) Technology Co., Limited 1519 Room, 6 Building Zhong Ang Times Plaza No. 9 Mentougou Road, Tou Gou District 102300 Beijing, China Tel: +86 (10) 8893 9660 [email protected] www.pce-instruments.cn
Spain
PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 [email protected] www.pce-instruments.com/espanol
Turkey
PCE Teknik Cihazlari Ltd.ti. Halkali Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece – stanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 [email protected] www.pce-instruments.com/turkish
Hong Kong
PCE Instruments HK Ltd. Unit J, 21/F., COS Centre 56 Tsun Yip Street Kwun Tong Kowloon, Hong Kong Tel: +852-301-84912 [email protected] www.pce-instruments.cn
© PCE Instruments 8
References
France.fr : Actualités, destinations et infos du tourisme en France
iberica.es
Make an offer on the domain instruments.co.uk - Domains.co.uk
Computer Instruments | Home
Discover Italy: Official Tourism Website - Italia.it
PCE(北京)科技有é™å…¬å¸
Industrial Measurement Products and Solutions | PCE Instruments
PCE Deutschland GmbH Prüfgeräte vom Hersteller | PCE Instruments
PCE Brookhuis B.V. | PCE Instruments
PCE Americas Inc. : Test Instruments | PCE Instruments
PCE Iberica S.L. Instrumentación | PCE Instruments
PCE Instruments France | PCE Instruments
PCE Italia s.r.l. / Strumenti di Misura | PCE Instruments
PCE Teknik Cihazlar Paz. Tic. Ltd.Şti. | PCE Instruments
PCE Americas Inc. : Test Instruments | PCE Instruments
PCE Americas Inc. : Test Instruments | PCE Instruments