Jojo Qb60 0.37kw Booster Pump Instruction Manual

QB60 0.37kW Booster Pump

Product Information: 0.37kW Booster Pump

The 0.37kW Booster Pump is a high-quality pump that is NRCS
approved and energy-efficient. It comes with a 1-year quality
warranty and offers dry running protection and over-current
protection. This pump is easy to operate and features an automatic
start/stop function. It is pre-wired with a 3-point plug.

The pump is suitable for use in bathrooms, misting, pop up,
impact, dishwasher, and washing machine applications. It has a
motor power of 0.37kW and a maximum flow of up to 20 lt/min. The
pressure range is between 1 to 2.4 bar.

The pump body is made of cast iron, the impeller is made of
brass, and the motor shaft is made of stainless steel 304. The
mechanical seal is made of ceramic-graphite.

Product Usage Instructions

Installation

Before installing the pump, ensure that the foundation is solid
enough to support the pump. It is recommended to secure the unit by
bolting it to concrete or a paved surface.

Recommended suction pipes are HDPE (minimum 1 or 25mm) or
helical coil reinforced flexible hose 1 or 25mm. The recommended
discharge pipe should be installed according to local
regulations.

Priming Instructions

It is important to prime the pump prior to use to ensure proper
functionality and to prevent possible damage to any of the
components. Follow these steps to prime the pump:

  1. Ensure that the ball valve between the tank and pump is
    open.
  2. Open the air valve on the pump casing by removing the priming
    screw, to allow the air in the volute to escape and for it to be
    filled with water via gravity feed. The suction line and pump
    should slowly fill with water until a steady flow is visible from
    the air valve. Note: this also ensures that all air has been
    removed from the casing and suction piping.
  3. If after a few seconds water is not visible from the air valve,
    fill the pump volute manually until it is overflowing.
  4. Put the priming screw back in place and then tighten. Do not
    over tighten.

Operating Instructions

After priming the pump, do the following to test it and ensure
proper operation:

  1. Ensure that the pump is connected to a power source.
  2. Turn on the pump using the automatic start/stop function.
  3. Check for any leaks or abnormal noises.

Automatic Pump Control

The pump features an automatic start/stop function that makes it
easy to operate. When water is needed, the pump will automatically
turn on and when the water demand is met, it will automatically
turn off.

0.37kW Booster Pump
Instructions for use

Features & Benefits
1-year Quality Warranty NRCS approved Energy-efficient
APPLICATIONS

Easy to operate Automatic start/stop function Pre-wired with a 3-point plug

August 2022
Dry running protection Over-current protection

Pump 0.37kW

Bathrooms 1

or

or

Misting 10

Pop up 2

Impact 1

Dishwasher Yes

Washing Machine Yes

Get the most out of your purchase!
· Add a JoJo Pump Cover to protect your pump from the elements and prolong its lifespan. · Add a JoJo Pump-to-Tank Connector Kit for seamless connection from your pump to a JoJo water tank.

1-year Quality Warranty
JoJo pumps purchased from an approved JoJo retail outlet and/or distributor carry a 1-year warranty from the date of purchase. In order to maintain your warranty, always ensure you install, operate and maintain the pump as per the instructions provided in this manual.

Detailed T’s and C’s, as well as return policies and procedures are in the back of this manual.

Performance table

Pump specifications Pump model Motor power Max. flow Max. pressure Max. fluid temperature Max. ambient temperature Max. suction lift

QB60 0.37kW 34 lt/min 3.8 bar 40 °C 40 °C 8m

Flow control switch Model Input voltage Frequency Current Max. power Protection

Best efficiency range
Flow range Lt/min

10 to 20 lt

Pressure range Bar

PERFORMANCE CURVE

SKD-2 220V 50 Hz 10 A 1500W | 2HP IP 44
1 to 2.4 bar

Additional pump details
Suction pipe (inches) Start-up amps (single phase) Running amps (single phase) Weight Dimensions: Length Width Height

1″ x 1″ 6.2 A 1.9 A 9 kg
280 mm 140 mm 170 mm

Construction characteristics Pump body Impeller Motor shaft Mechanical seal

Cast iron Brass Stainless steel 304 Ceramic-graphite

PUMP DIAGRAM

No. Description

1

O-Ring

2

Brass air vent screw

3

Flat washer

4

O-Ring

5

Stator

6

Motor bracket

7

Terminal board

8

Capacitor

No. Description

9

Capacitor cover

10

Cable fixer

11

Water proof ring

12

Bearing

13

End cover

14

Fan

15

Pump body

16

Impeller

No. Description

17

Shaft circlip

18

Mechanical seal

19

Coupling

20 Fan cover

21

Cable protector

22 Cable

23 Rotor

24 Wave spring

02

03

Important information
· The pump must be earthed with no strain placed on the electrical cable. · All maintenance should be carried out with the power supply disconnected. · The pump is only designed for clean water use i.e. water containing no solid particles. Pumping
muddy water or water containing suspended solids will severely reduce the life expectancy of the unit. Note: this type of application falls outside of the factory warranty. · Extending the cable will affect your factory warranty. Always make use of an approved extending plug adapter. · The pump should be installed in a ventilated, undercover area to protect the unit against direct sunlight, rain and spray from an irrigation system. A JoJo pump cover is recommended for best protection.

Recommended suction pipes: HDPE (minimum 1″ or 25mm) Helical coil reinforced flexible hose 1″ or 25mm

Recommended discharge pipe:
Copper, HDPE or any SABS approved piping (minimum ¾ inch or 22mm)

INSTALLATION

Foundation Mounting

The foundation should be solid enough to support the pump. It is recommended to secure the unit by bolting it to concrete or a paved surface.
Before building the foundation, take the following into consideration: · The placement of the pump incl. the direction of inlet/outlet. · The height – ensure that the water level in the tank is higher than the suction
side of the pump.
· Ensure the pump base is level so that the pump shaft is aligned horizontally. · The pump suction line and fittings must all be on a horizontal plane. · The discharge line and fittings must be on a vertical plane.

Piping
04

· The suction and discharge pipes should be supported independently by utilising pipe hangers and support blocks – this will prevent strain on the pump joints and casing.
· Before making a connection, always check the pipe alignment to ensure it is correct.
· The inlet and discharge pipe should align with the pump to ensure there are no bends or kinks that might affect the flow.
· The inlet and discharge pipe/connections must correspond with the design specifications of the pump as it may directly affect the efficiency and power consumption of the pump.
· The diameter of the suction and discharge pipe must be equal or greater than that of the ports of the pump.
· When being used as an alternative water supply for a home, install non-return valves to ensure no back pressure to the municipal supply or the pump.

PRIMING INSTRUCTIONS

IMPORTANT: the pump needs to be primed prior to use to ensure proper functionality and to prevent possible damage to any of the components.
01. Ensure that the ball valve between the tank and pump is open. 02. Open the air valve on the pump casing by removing the priming screw, to allow the air in the volute to
escape and for it to be filled with water via gravity feed. The suction line and pump should slowly fill with water until a steady flow is visible from the air valve. Note: this also ensures that all air has been removed from the casing and suction piping. 03. If after a few seconds water is not visible from the air valve, fill the pump volute manually until it is overflowing. 04. Put the priming screw back in place and then tighten. Do not over tighten.

02

03

04

OPERATING INSTRUCTIONS After priming the pump, do the following to test it and ensure proper operation:

b a

AUTOMATIC PUMP CONTROL
POWER

TYPE: PS02.1
RESET 220 – 240 50 / 60 Hz 10Amax. 10BARMAX. IP 65

FAILURE ON

01. Check that the ball valve (a) between the tank and the pump is open and that the discharge valve (b) on the pump is closed. Note: it is always advised to install a ball valve between pump and tank for maintenance purposes.

02. Insert the plug into the main power supply and switch the plug on. The power indicator light of the flow controller must be illuminated.
05

Operating instructions (continued)

AUTOMATIC PUMP CONTROL
POWER

TYPE: PS02.1
RESET 220 – 240 50 / 60 Hz 10Amax. 10BARMAX. IP 65

FAILURE ON

AUTOMATIC PUMP CONTROL
POWER

TYPE: PS02.1
RESET 220 – 240 50 / 60 Hz 10Amax. 10BARMAX. IP 65

FAILURE ON

03. Open the discharge valve (b), the pump should start automatically.

04. Close the discharge valve (b), the pump will switch off within 15 to 20 seconds (this is a built-in safety feature that protects the pump). This tests the pressure controller operation.

AUTOMATIC PUMP CONTROL
POWER

TYPE: PS02.1
RESET 220 – 240 50 / 60 Hz 10Amax. 10BARMAX. IP 65

FAILURE ON

AUTOMATIC PUMP CONTROL
POWER

TYPE: PS02.1
RESET 220 – 240 50 / 60 Hz 10Amax. 10BARMAX. IP 65

FAILURE ON

05. Close the inlet valve (a) and open the discharge valve (b). The pump will switch on and run for 15 to 20 seconds. The pump should then stop operating and the failure light on the flow controller should be illuminated. This tests the run dry operation.

06. Open the inlet valve (a) and press the reset button on the flow controller. The pump will start running. After completing steps one to six, the pump will be ready for use.

MAINTENANCE INSTRUCTIONS

IMPORTANT: it is advised to run the pump at least once a month to prevent the impeller from getting stuck. Should the impeller get stuck (typically due to sediment in the water), you can follow these guidelines to clean and test it.

To clean the pump, you will require:
06

A CLEAN CLOTH

SIZE 8 SPANNER

FLAT POINT

WATER PUMP

SCREW DRIVER

PLIERS

100/120 GRIT SAND PAPER

Open the pump to confirm if the impeller needs cleaning.

01

02

03

04

With the pump inlet facing you, remove the 3 x 6mm screws from the front casing.

Split the front cover from the pump.

Move the cover away from the pump. Be careful not to damage the electrical cord.

If the wear-plate or impeller is dirty, dirt will be visible as indicated in the image above.

If the impeller needs cleaning, simply do the following:

05

06

07

08

Using a piece of sandpaper gently clean the surface where the impeller runs.

Next clean behind the impeller and casing. Once done, wipe both sides with a cloth.

Make sure the O-Ring is in place (as indicated in the image above), before re-fitting the front cover.

Replace the front cover and refit the 3 x 6mm screws to it.

Test the pump to ensure it has been cleaned properly.
09
Note: we recommend testing the pump before connecting it to the water supply.

Tighten the 3 screws on the cover, making sure not to over tighten them.

10. Insert the plug into the main power supply and switch it on. The pump should start up immediately and run for 20 seconds, after which it will shut down (a built in safety feature to prevent dry run).
11. Reset the pump by pressing the reset button on the pressure switch. 12. Reconnect your pump to your water supply as per the operation instructions on
pages 5 and 6 in this manual.

JOJO PUMP WARRANTY
Please read this warranty in conjunction with the South African Consumer Protection Act 68 of 2008.
01. JoJo warrants its pumps to the original end user/purchaser to be free of defective materials and workmanship under normal use for a period of 12-months from the date of purchase from authorised retailers and distributors. To be eligible for warranty repair or replacement, the pump must be returned to the point of purchase during and up to the expiry date of the warranty period. Proof of date of purchase is required.
02. Liability in terms of this warranty shall be limited to repair or replacement of the pump. Liability for all and any other losses and/or subsequent damages suffered are expressly excluded. 07

Pump Warranty (continued)
03. This warranty does not obligate JoJo to bear any cost of removal, installation, transportation, or other charges which may arise in connection with a warranty claim.
04. The warranty shall not apply to repairs or service necessitated by normal wear and tear or for lack of reasonable and proper maintenance. This warranty does not apply if in the sole judgement of JoJo the product or any of the components have been; (a) Tampered with, disassembled (unless as per JoJo’s specific instructions relevant to peripheral pumps and clearly displayed on fan cover), repaired or altered (except as may be pre-authorised by JoJo in writing); (b) Subjected to misapplication, misuse, neglect or accident; or (c) Used to pump anything for which the pump was not designed. Such use may compromise or harm the pump and/or any of its components.
IMPORTANT: this is the exclusive warranty given by us and no other warranty or guarantees, expressed or implied shall be of any force or effect. No distributor or other person is authorised to assume any liability or obligated for JoJo other than expressly provided herein.
RETURN POLICIES AND PROCEDURES
Refunds
Within 5 days of purchase; as part of the cooling off clause (section 16 of the CPA), the pump may be returned for refund, provided that it is still within the original packaging, unused, and in the original condition.
Within 10 days of purchase; the pump may be returned for refund or replacement if it does not meet the purpose for which intended (section 20 of the CPA) l provided that it is still within the original packaging, unused, and in the original condition. In such instance the pump will be returned to JoJo for an evaluation, after which an inspection report will be provided confirming whether it meets the necessary requirements for refund or replacement.
Returns/repairs
Within 12 months; should the pump not operate as specified, or cease to do so within 12 months after being purchased, the return procedure is as follows: · Return the pump to the store from which purchased, together with the proof of purchase (to confirm that it is
within the 12-month warranty period). Please ensure that the condition of the pump is as specified in section four of this warranty, and that it is still packed in the original packaging. · The store will send the pump to the nearest JoJo factory for an evaluation. · At JoJo’s election, (a) the pump will either be repaired (if repairable) which repairs shall be and warranted for three months, or the balance of the 12-month period, whichever period is longer; or (b) the pump will be exchanged (this only applies if the pump is non-repairable, and a replacement pump in similar visual condition will be provided by JoJo). · The evaluation (once the pump is sent back to JoJo), repair/exchange and delivery to the store will take place within 14 days.
Our return/repair request form is available on our website at www.jojo.co.za.
Thank you for choosing JoJo. If there is anything that you are unsure about or need assistance with, please do not hesitate to contact us.
www.jojo.co.za | +27 11 695 8300 08

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals