CC10006X AirSim Child Combo X
Product Information
The AirSim Child Combo X is a training manikin designed for
medical education purposes. It is lightweight, weighing
approximately 2.6kg, and comes with a package weight of
approximately 3kg. The full shipment dimensions are 40 x 24 x 22cm.
The product code for the AirSim Child Combo X is CC10006X.
Recommended Equipment Sizes
If required, the recommended equipment sizes for use with the
AirSim Child Combo X can be found in the user manual.
Product Usage Instructions
Initial Set-Up
Before using the AirSim Child Combo X, follow these initial
set-up instructions:
- Refer to the user manual for a list of procedures facilitated
by the manikin.
Replacement of Consumables
To replace the larynx insert, follow these steps:
- Ensure the manikin head is placed in a neutral position.
- Remove the wraparound neck skin to access the larynx
insert. - Discard the old larynx insert.
- Align a new insert into position and press it firmly into
place, ensuring the ridges at all corners are tightly aligned with
the larynx insert frame.
Care and Maintenance
To care for and maintain the AirSim Child Combo X, follow these
guidelines:
- Store the manikin in clean, dry conditions away from heat and
direct sunlight. - Avoid contact with metals, solvents, oils, greases, and strong
detergents. - When not in use, store the manikin in the provided black
carrier case. - Thoroughly wash the AirSim X airway in warm water using warm
soapy water or a similar cleanser until all visible foreign matter
and residue is removed. - Mild detergents or enzymatic cleaning agents may be used on the
airway, following the manufacturer’s instructions and proper
dilution. Ensure the detergent does not contain skin or mucous
membrane irritants. - Do not use any of the following when cleaning the AirSim
product range:- Metals
- Solvents
- Oils or greases
- Strong detergents
- In response to the recent COVID-19 pandemic, it is recommended
to use alcohol spray (minimum 75%) to sanitize the silicone skin
and latex airway. Wipe off the spray and repeat this process 3-4
times to ensure complete virus elimination.
Warranty
The AirSim Child Combo X comes with a 1-year warranty from the
date of delivery. If the unit malfunctions, it must be returned to
the factory for evaluation. If found defective, it will be repaired
or replaced at no charge. Additionally, TruCorp offers a 5-year
warranty on TruCorp branded airways for the AirSim X, Trauma X, and
TruBaby X ranges. This warranty only covers the actual TruCorp
airway and not any other part of the model.
For all warranty and repair inquiries, please contact TruCorp
Ltd:
Address: 33 Waringstown Road, Lurgan, Co. Armagh BT66 7HH,
Northern Ireland
Email: [email protected]
Telephone: +44 (0) 28 3888 2714
Contents
Product specifications ……………………………………………………………………………………………..2 Package contents ……………………………………………………………………………………………………..2 Recommended equipment sizes …………………………………………………………………………….2 Initial set-up information ………………………………………………………………………………………….3 List of procedures facilitated by the AirSim Child Combo X ……………………………..3 Replacement of consumables……………………………………………………………………………….. 4 Care and maintenance …………………………………………………………………………………………….5 Warranty ……………………………………………………………………………………………………………………..5
1
Product specifications
Product Code: CC10006X AirSim Child Combo X weight: Approx. 2.6kg Full shipment weight: Approx. 3kg Full shipment dimensions: 40 x 24 x 22cm
Package contents
· 1 AirSim Child Combo X ready-to-use (CC10006X) · 1 AirSim Child Combo X carrier case (CBAG03) · 100ml bottle of lubrication (TL001) · 5 Larynx inserts (CNLX050 1 supplied on the manikin and 4 spare) · 1 wraparound neck skin (CRSN1005 supplied on manikin) · 2 sets of adhesive pads (attachable to suction cups for increased stability
if required)
Recommended equipment sizes
· 4.5-5.0 mm ID for nasal intubation · 5.5-6.0 mm ID for oral intubation · Size 2 for LMA laryngeal masks · Size 2 laryngoscope blade · Similar respective sizes for other supraglottic devices
2
Initial set-up information
· Gently remove the model from the carrier case · Secure the manikin to a suitable surface by adjusting the screw on the
suction cups (surface must be non-porous to ensure sufficient suction) · Optional: Adhesive pads are provided with the model for increased
stability if required. This is particularly useful when the product is not on an ideal surface for suction cups to be effective. Simply peel the cover from the pad to locate the adhesive area and attach to the suction cups. · The head can be placed in a neutral or sniffing position by rotating the head, if required for direct laryngoscopy · Check the volume of air in the tongue is sufficient, it can be inflated or deflated by a syringe to adjust the difficulty during intubation if desired · Please ensure two lung bags and one stomach bag are attached to the airway and oesophagus respectively · Spray generous amounts of lubrication provided with the model (TL001) on the airway and equipment prior to use
List of procedures facilitated by the AirSim Child Combo X
· Needle and surgical cricothyroidotomy · Percutaneous tracheostomy · Double naso-tracheal intubation · Bag valve mask (BVM) ventilation techniques · Full range of supraglottic devices · Direct laryngoscopy · Endotracheal tube insertion · Awake fibre optic examination · Combi tube insertion · Video laryngoscopy (including Sellick Manoeuvre) · Naso-gastric tube insertion techniques
3
Replacement of consumables
The larynx insert is designed to be replaced for each student to provide a unique training experience. This is a very quick and easy process, perfect for a busy teaching environment. 1. Please ensure the manikin head is placed in a neutral position 2. Remove the wraparound neck skin to provide access to the larynx insert 3. Remove the larynx insert and discard:
4. Align a new insert into position and press into place. Please ensure the ridges at all corners of the insert (yellow areas circled below) are tightly aligned with the larynx insert frame:
4
Care and maintenance
Store in clean, dry conditions away from heat and direct sunlight; avoid contact with metals, solvents, oils or greases and strong detergents. When the product is not in use please store in the black carrier case provided.
Thoroughly wash the AirSim X airway in warm water. Please use warm soapy water or something similar until all visible foreign matter and residue is removed.
Mild detergents or enzymatic cleaning agents may be used on the airway in accordance with the manufacturer’s instructions and at the proper dilution. The detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim product range
· Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g. Cidex®),
· Ethylene oxide, phenol-based cleaners or iodine-containing cleaners
In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the product is fully sanitised:
Use alcohol spray (minimum 75%) and wipe off. Repeat this for 3-4 times to ensure to kill the virus completely. This method can be used on both the silicone skin and the latex airway.
Warranty
TruCorp warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 1-year from the date of delivery. This ensures that our customers receive maximum coverage on each product. If the unit should malfunction it must be returned to the factory for evaluation. Upon examination by TruCorp, if the unit is found to be defective it will be repaired or replaced at no charge.
Additionally, TruCorp warrants a 5-year warranty on TruCorp branded airways on any AirSim X, Trauma X and TruBaby X range. The 5-year warranty only covers the actual TruCorp airway and not any other part of the model.
5
TruCorp will pay for the freight/delivery and the actual parts needed free of charge if any part of the product fails within the 1-year period. TruCorp will pay for the freight/delivery of the TruCorp airway free of charge if the airway fails within the 5-year period. However, these warranties are VOID, if; the unit shows evidence of having been tampered with or shows evidence of having been damaged by excessive heat, the use of sharp instruments, misapplication, misuse or other operating conditions outside of TruCorp’s control. Components which wear or are damaged by misuse are not warranted and will be charged for if repair has been approved. Warranty is void if third party products are seen to have damaged or caused failure of the TruCorp models.
Please direct all warranty and repair inquiries to:
TruCorp Ltd 33 Waringstown Road
Lurgan, Co. Armagh BT66 7HH
Northern Ireland [email protected] Tel: +44 (0) 28 3888 2714
6