Arrow Cda-42854-p1a Pressure Injectable Lumen Cvc Instruction Manual

Arrow Cda-42854-p1a Pressure Injectable Lumen Cvc Instruction Manual

ARROW-logo ARROW CDA-42854-P1A Pressure Injectable Lumen CVCARROW CDA-42854-P1A Pressure Injectable Lumen CVC-productPressure Injectable Arrowgtard Blue Plus

Contents:

  1. Arrowg+ard Blue Plus@1 Four-Lumen Catheter: 8.5 Fr. (3.0 mm OD) x 16 cm, Pressure Injectable
  2. Spring-Wire Guide, Marked: 032″ (0.81 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End- “J” Tip on Other) with Arrow Advancer Catheter 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle Pressure Transduction Probe
  3. Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
  4. Injection Needle: Eclipse TM2 22 Ga. x 1-1/2″ (3.81 cm) RW and 5 mL Luer-Slip Syring
  5. Injection Needle: Eclipse TM2 25 Ga. x 1″ (2.54 cm) RW and 3 mL Luer-Lock Syringe Syringe: 10 mL Luer-Lock
  6. Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm SecondSite”M Adjustable Hub: Fastener
  7. Second Site TM Adjustable Hub: Catheter Clamp SharpsAway® Disposal Cup SharpsAway@ II Locking Disposal Cup
  8. Maximal Barrier DrapeT with 4″ fenestration Towel 1
  9. Needle Holder
  10. Forceps
  11. Safety Scalpel: #11
  12. Checklist/CLIP Sheet Sterile Procedure Sign
  13. Gauze Pad: 2″x2″ (5 cmx5 cm)
  14. gauze Pad: 4″ x 4″ (10 cm x 10 cm)
  15. Dressing: Tegaderm@3 10 cm x 12 cm
  16. Surgical Apparel: Impervious Gown
  17. Surgical Apparel: Bouffant Cap
  18. Surgical Apparel: Mask with Eye Shield
  19. Suture: 3-0 Silk with Curved Needle
  20. HemoHopper® Fluid Receptacle licensed under US Patent No. 7,329,412. 2A trademark of Becton, Dickinson and Company. 3A registered trademark of 3M Company.

Not made with natural rubber latex. Store below 25°C (77°F). Avoid excessive heat above 40°C (104°F).

Contraindications

The Arrowg+ard Blue Plus antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs.

Distal (16 Ga.)0.3827815
Medial 1 (14 Ga.)0.45498010

Priming volumes are approximate and are done without accessories.
Flow rate values are approximate and are determined using deionized water at 100 cm head height.
** Pressure injection flow rates are determined using media of 11.8 centipoises (cP) viscosity, with 152 cm administration set tubing