Pce Instruments Pce-127 Series Flow Cup Meter User Manual

PCE-127 Series Flow Cup Meter

Product Information

The Manual Flow Cup Meter PCE-127 Series is a device
manufactured by PCE Instruments. It is designed for measuring flow
rates and is suitable for use in various industries. The meter is
equipped with a flow cup and provides accurate measurements of
liquid flow.

The PCE-127 Series Flow Cup Meter is available in different
models with varying technical specifications. The meter comes with
a user manual that provides detailed information on its operation,
safety instructions, and maintenance procedures.

Product Usage Instructions

1. Safety Notes

Before using the PCE-127 Series Flow Cup Meter, it is important
to read and understand the safety notes provided in the user
manual. These notes outline the precautions that need to be taken
to ensure safe operation of the device.

Only qualified personnel should operate the flow cup meter, and
any repairs should be carried out by PCE Instruments personnel.
Non-compliance with the safety instructions may result in damage or
injuries that are not covered by warranty.

2. Specification

The user manual contains detailed technical specifications of
the PCE-127 Series Flow Cup Meter. It provides information on the
device’s measurement range, accuracy, power supply requirements,
and other relevant parameters. Refer to this section for a
comprehensive understanding of the meter’s capabilities.

3. System Description

This section provides an overview of the flow cup meter’s system
description. It explains the components of the meter and how they
work together to measure flow rates accurately. Familiarize
yourself with this information to better understand the device’s
functionality.

4. Operation

4.1 Preparing the Measurement

Prior to taking measurements using the PCE-127 Series Flow Cup
Meter, it is necessary to follow the instructions provided in this
section. It includes steps such as preparing the meter, connecting
it to the liquid source, and ensuring proper calibration.

4.2 Taking a Measurement

This section explains the step-by-step process of taking
measurements with the flow cup meter. It covers procedures such as
filling the flow cup, timing the flow, and recording the results.
Follow these instructions carefully to obtain accurate and reliable
measurements.

4.3 Maintenance

Maintenance is an essential aspect of ensuring the longevity and
performance of the flow cup meter. This section provides guidelines
on how to clean and maintain the device properly. It also includes
information on recommended maintenance intervals and
procedures.

5. Contact

For any inquiries or support related to the PCE-127 Series Flow
Cup Meter, contact PCE Instruments using the provided contact
details. The user manual lists the contact information for PCE
Instruments UK and PCE Americas separately. Reach out to the
respective office based on your location.

6. Disposal

This section provides instructions on the proper disposal of the
flow cup meter. Follow the guidelines mentioned in this section to
ensure environmentally friendly disposal of the device.

7. Contact

7.1 PCE Instruments UK

For customers located in the United Kingdom, contact PCE
Instruments UK using the provided contact details for any further
assistance or inquiries.

7.2 PCE Americas

For customers located outside of the United Kingdom, contact PCE
Americas using the provided contact details for any further
assistance or inquiries.

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 [email protected]

PCE Instruments UK Ltd. Units 12/13
Southpoint Business Park Ensign way
Hampshire / Southampton United Kingdom, SO31 4RF
From outside UK: +44 Tel: (0) 2380 98703 0 Fax: (0) 2380 98703 9 [email protected]

www.pce-instruments.com/english www.pce-instruments.com

Manual Flow Cup Meter PCE-127 Series

Version 1.0 Date of creation: 09.06.2016 Date of last change: 10.06.2016

Manual

Contents

1 Safety notes……………………………………………………………………………………………….2

2 Specification………………………………………………………………………………………………3

2.1

Technical specifications……………………………………………………………………………………………….. 3

2.2

Delivery contents ………………………………………………………………………………………………………… 3

2.3

Optional accessories …………………………………………………………………………………………………… 3

3 System description …………………………………………………………………………………….3

4 Operation …………………………………………………………………………………………………..4

4.1

Preparing the measurement …………………………………………………………………………………………. 4

4.2

Taking a measurement………………………………………………………………………………………………… 4

4.3

Maintenance ………………………………………………………………………………………………………………. 4

5 Contact…………………………………………………………………………………………………….5

6 Disposal …………………………………………………………………………………………………….5

7 Contact………………………………………………………………………………………………………5

7.1

PCE Instruments UK …………………………………………………………………………………………………… 5

7.2

PCE Americas ……………………………………………………………………………………………………………. 5

Thank you for purchasing a flow cup meter from PCE Instruments.
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage the meter.
You must not make any technical changes to the device. The appliance should only be cleaned with a cloth and suitable cleaning agents. Do not use
aggressive agents or abrasives and do not use wire brushes, metal scrapers or other metallic tools for cleaning. Clean the flow cup meter after each use and make sure that it is dry and free from residues before storing it. The device must only be used with accessories from PCE Instruments or equivalent. Before each use, inspect the cup for visible damage. If any damage is visible, do not use the device.
This user’s handbook is published by PCE Instruments without any guarantee.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments.

2

Manual

2 Specification

2.1 Technical specifications
Capacity Ø nozzle Standard Flow time Dynamic viscosity Material Dimensions
Weight

Immersion cup

Flow cup

PCE-127/4P

PCE-127/4

100 ml

4 mm (±0.02 mm)

DIN 53211

25 … 150 s

96.2 … 680 mPa * s

Cup: anodized aluminium

Nozzle: stainless steel

Inner Ø: 50 mm Outer Ø: 65 mm Height: 78 mm Handle length: 170 mm

Inner Ø: 50 mm Outer Ø: 65 mm Height: 70 mm

Approx. 215 g

Approx. 200 g

2.2 Delivery contents
1 x flow cup PCE-127/4 or immersion cup PCE-127/4P 1 x glass plate (PCE-127/4 only) 1 x factory certificate 1 x instruction manual

2.3 Optional accessories – Stand BDG 130

3 System description

handle cup
nozzle immersion cup PCE-127/4P

overflow gutter
cup

flow cup PCE-127/4

nozzle

3

Manual
4 Operation
4.1 Preparing the measurement To perform a measurement, you need a stopwatch. Also, please mind the following notes to prepare the measurement:
Make sure that the cup and the nozzle are clean and free from residues. The liquid to be measured has to be homogeneous and free from air bubbles. Do not let the
sample rest for too long. The sample should be freshly strained (e. g. by stirring) before starting the measurement. Allow some time for the fluid and the cup for temperature compensation. Measure and note down the temperature of the liquid. You can only measure Newtonian fluids with the flow cup. To check if the sample is Newtonian, observe the measuring procedure (see chapter 4.2) and follow these steps:
o Fill the cup and measure the flow time immediately. o Fill the cup again and wait one minute before measuring the flow time. o If the deviation between both results is above 10 %, the sample is a non-Newtonian fluid.
In this case, you cannot measure it with the flow cup.
4.2 Taking a measurement
Immersion cup PCE-127/4P
1. Immerse the flow cup into the sample until it is filled completely. 2. Quickly pull the flow cup out of the fluid and start the flow time measurement at the same time.
Make sure that you hold the flow cup vertically during the whole measurement. 3. Watch the fluid coming out of the nozzle. Once the flow breaks, stop the flow time measurement. 4. Repeat the measurement. 5. If the results of both measurements do not deviate by more than 5 %, calculate the average and
note it down. 6. After that, you can calculate the viscosity by using a viscosity nomogram, for example.
Flow cup PCE-127/4
1. Place the cup in a way that the nozzle is aligned vertically and not blocked. 2. Place a finger on the nozzle to cover it. 3. Fill the cup to the brim. Pour the fluid into the cup gently to prevent the formation of air bubbles. 4. Slide the glass plate over the rim of the cup until it is covered completely. Excess sample is
absorbed by the overflow gutter. 5. Remove your finger from the nozzle and wait a while to allow air bubbles to get to the surface. 6. Remove the glass plate and start the flow time measurement at the same time. 7. Watch the fluid coming out of the nozzle. Once the flow breaks, stop the flow time measurement. 8. Repeat the measurement. 9. If the results of both measurements do not deviate by more than 5 %, calculate the average and
note it down. 10. After that, you can calculate the viscosity by using a viscosity nomogram, for example.
4.3 Maintenance The flow cups of the PCE-127 series are low-maintenance devices. If you need to perform calibration checks on a regular basis (e. g. in line with a quality management system) we offer a variety of calibration oils.
4

Manual
5 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
6 Disposal
For the disposal of batteries, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. If you have any questions, please contact PCE Instruments.
7 Contact
If you have any questions about our range of products or measuring instruments please contact PCE Instruments. 7.1 PCE Instruments UK By post: PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF By phone: 02380 987 035
7.2 PCE Americas By post: PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter 33458 FL USA By phone: 561 320 9162
5

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals