The Rover 100A MPPT Solar Charge Controller is a versatile and
efficient charge controller designed for use with 12V, 24V, 36V,
and 48V DC system voltages (for non-lithium batteries). It is
compatible with a variety of Deep Cycle battery options, including
AGM, Sealed, Gel, Flooded, and Lithium batteries. The controller
features innovative MPPT technology with high tracking efficiency
of up to 99% and peak conversion efficiency of 98%.

Product Specifications:

  • Model: Rover 100A MPPT Solar Charge
    Controller
  • Terminal Range: Not specified
  • Grounding: Not specified
  • Communication: Not specified
  • Operating Temperature: Not specified
  • Storage Temperature: Not specified
  • Humidity: Not specified
  • Dimensions (LxWxH): Not specified
  • Weight: Not specified
  • Regulatory and Safety Specifications: Not
    specified

Charger Data:

  • Rated Battery Input Voltage: 12VDC
  • Battery Input Voltage Range: 10VDC~60VDC
  • Rated Charge Current: 100A
  • Rated Solar Input Power: 1300W (12V Battery);
    2600W (24V Battery); 3900W (36V Battery); 5200W (48V Battery)
  • Maximum Solar Input Power: 1300W (12V
    Battery); 2600W (24V Battery); 3900W (36V Battery); 5200W (48V
    Battery)
  • Maximum Solar Input Voltage (Voc): Not
    specified
  • Solar Input Voltage Range (Voc): Not
    specified
  • Power Consumption: Not specified
  • MPPT Tracking Efficiency: Not specified
  • Conversion Efficiency: Not specified
  • Charger Efficiency: Not specified
  • MPPT Operating Voltage Range: Not
    specified
  • Temperature Compensation: Not specified
  • Charger Algorithm: Not specified
  • Charger Preset: Not specified

Battery Charging Data:

Battery TypeOverVolts ShutdownEqualization VoltageBoost VoltageFloat VoltageBoost Return VoltageLow Voltage ReconnectUnder Voltage WarningLow Voltage WarningLow Voltage DisconnectBoost DurationEqualization Duration
AGM/SLD16.0V14.6V14.4V13.8V13.2V12.6V12.0V11.1V10.6V120min120min
GEL16.0V-14.2V13.8V13.2V12.6V12.0V11.1V10.6V120min
FLD16.0V14.8V14.6V13.8V13.2V12.6V12.0V11.1V10.6V120min120min
LI16.0V-14.4V-13.2V12.6V12.0V11.1V10.6V
USER(Default)16.0V14.6V14.4V13.8V13.2V12.6V12.0V11.1V10.6V120min120min

Product Usage Instructions

To use the Rover 100A MPPT Solar Charge Controller, follow these
steps:

  1. Ensure that the battery input voltage is within the range of
    10VDC to 60VDC.
  2. Connect the Deep Cycle battery to the charge controller.
  3. Connect the solar panels to the solar input terminals of the
    charge controller.
  4. Set the battery type based on the battery being used (AGM/SLD,
    GEL, FLD, LI, or USER).
  5. Adjust the charging parameters as needed to match the battery
    specifications:
  • OverVolts Shutdown: The voltage at which the
    charge controller shuts down charging to prevent overcharging.
  • Equalization Voltage: The voltage at which the
    charge controller performs an equalization charge to balance the
    battery cells.
  • Boost Voltage: The voltage at which the charge
    controller switches to boost charging mode.
  • Float Voltage: The voltage at which the charge
    controller maintains a constant voltage to keep the battery fully
    charged.
  • Boost Return Voltage: The voltage at which the
    charge controller returns to normal charging mode after boost
    charging.
  • Low Voltage Reconnect: The voltage at which
    the charge controller reconnects the load after a low voltage
    disconnect.
  • Under Voltage Warning: The voltage at which
    the charge controller provides a warning for low battery
    voltage.
  • Low Voltage Warning: The voltage at which the
    charge controller provides a warning for critically low battery
    voltage.
  • Low Voltage Disconnect: The voltage at which
    the charge controller disconnects the load to prevent deep
    discharge of the battery.
  • Boost Duration: The duration of boost charging
    mode.
  • Equalization Duration: The duration of
    equalization charging mode.
  • Once the charging parameters are set, the charge controller
    will automatically detect the system voltage and start charging the
    battery using MPPT technology.
  • Monitor the charging process using the charge controller’s
    indicators and adjust the parameters if necessary.

    Note: For specific operating temperature, storage temperature,
    humidity, dimensions, weight, and regulatory/safety specifications,
    please refer to the product manual or contact the manufacturer.

    ROVER 100A MPPT SOLAR CHARGE CONTROLLER

    ROVER 100A MPPT SOLAR CHARGE CONTROLLER
    Introducing the Renogy Rover 100A MPPT Charge Controller, the largest Rover controller that Renogy has to offer. Capable of supporting up to 1300 watts on 12 volts, 2600 watts on 24 volts, 3900 watts on 36V and 5200 watts on 48V. This off-grid controller was designed for large-scale projects, both mobile and stationary. For even more power, users can utilize a unique feature limited to this Rover and connect two 100A. Rover controllers in parallel for a total of 200 amps! This smart charge controller can also conveniently self-diagnose itself in the event of an error and can be remotely controlled through the Renogy DC Home app using the Renogy BT-1/BT-2 Bluetooth Module. By pairing the Rover with the BT-1/BT-2 and the Renogy DC Home app through Bluetooth, users can easily monitor and adjust their solar system straight from their phones.

    FEATURES
    Automatically detects 12V, 24V, 36V and 48V DC system voltages (for non-lithium batteries). Compatible with various Deep Cycle battery options: AGM, Sealed, Gel, Flooded and Lithium. Innovative MPPT technology with high tracking efficiency up to 99% and peak conversion efficiency of 98%.
    Electronic protection against reverse polarity, overcharging, over-discharging, overload, short-circuiting, and reverse current. LCD screen and multiple LED indicators for displaying system operation information, customizable parameters, and error codes. RS232 and RS485 ports. RS232 allows the Rover to communicate with the BT-1 Bluetooth module, which can pair with the DC Home smartphone app. RS485 allows the Rover to communicate with the BT-2 Bluetooth module, which can pair with the DC Home smartphone app.

    RENOGY.COM

    5050 South Archibald Avenue, Ontario, CA 91762, USA

    PRODUCT SPECIFICATION
    GENERAL DATA Model Terminal Range Grounding Communication Operating Temperature Storage Temperature Humidity Dimensions (LxWxH) Weight Regulatory and Safety Specifications

    RNG-CTRL-RVR100 8AWG – 6AWG Common Negative RS232;RS485 -31°F- 113°F /-35°C – 45°C -13°F -167°F /-35°C – 75°C 0%~95% RH 12.07 x 17.44 x 4.33 inch / 305 x 443 x 110 mm 22.0 lbs/ 9.9kg FCC Part 15 Class B; CE; RoHS

    CHARGER DATA Rated Battery Input Voltage Battery Input Voltage Range Rated Charge Current Rated Solar Input Power Maximum Solar Input Power Maximum Solar Input Voltage (Voc) Solar Input Voltage Range (Voc) Power Consumption MPPT Tracking Efficiency Conversion Efficiency Charger Efficiency MPPT Operating Voltage Range
    Temperature Compensation
    Charger Algorithm
    Charger Preset

    12VDC 10VDC~60VDC 100A
    1300W (12V Battery);2600W (24V Battery);3900W (36V Battery);5200W (48V Battery)
    1300W (12V Battery);2600W (24V Battery);3900W (36V Battery);5200W (48V Battery)
    150VDC (25¥);140VDC(-25¥) 17VDC~150VDC 2.7-2.9W >99% 98% 95% 17VDC~150VDC -3mV / ¥ / 2V (Non-Lithium) 0mV / ¥ / 2V; no compensation (Lithium) 3-stage Lead Acid, Bulk, Boost, Float, Equalize* 2-Stage Lithium, Bulk, Boost AGM, Gel, Flooded, Lithium-iron Phosphate, User Custom

    BATTERY CHARGING DATA
    Battery TYPE OverVolts Shutdown Equalization Voltage Boost Voltage Float Voltage Boost Return Voltage Low Voltage Reconnect Under Voltage Warning Low Voltage Warning Low Voltage Disconnect Boost Duration Equalization Duration

    AGM/SLD 16.0V 14.6V 14.4V 13.8V 13.2V 12.6V 12.0V 11.1V 10.6V
    120min 120min

    GEL 16.0V
    -14.2V 13.8V 13.2V 12.6V 12.0V 11.1V 10.6V 120min

    FLD 16.0V 14.8V 14.6V 13.8V 13.2V 12.6V 12.0V 11.1V 10.6V 120min 120min

    LI 16.0V
    -14.4V
    -13.2V 12.6V 12.0V 11.1V 10.6V

    USER(Defaul) 16.0V 14.6V 14.4V 13.8V 13.2V 12.6V 12.0V 11.1V 10.6V
    120min 120min

    RENOGY.COM

    5050 South Archibald Avenue, Ontario, CA 91762, USA