NMDP42-G35-55-12 Water Pressure Diaphragm Pump
Diaphragm Pump Instruction Manual
Diaphragm Pump NMDP42-G35-55-12
If you have any product questions or need technical support,
please contact us at [email protected]. Please read all
manual instructions carefully before operating. VEVOR reserves
clear interpretation of our user manual. The appearance of the
product shall be subject to the product you received. Please note
that we won’t inform you again if there are any technology or
software updates on our product.
Product Specifications
- Rated Voltage: 12V
- Number of Chambers: 4 PCS
- Rated Pressure: 55 PSI
- Max. Flow: 3.5 GPM
- Inlet/Outlet Diameter: 1/2 MNPT
Features
- 4-chamber diaphragm pump
- 5min on 10min off
- Bypass: reduces cycling
- Run dry capable for normal workloads
- Automatic: controlled by pressure switch
- Industry-standard mounting pattern
- Self-priming
- Quiet operation
- Ignition protected
Applications
- Yacht/RV/caravan pressurized water system
- Sprayer fixtures (vehicle-mounted sprayers, electric
sprayers) - Cleaning machines, humidifiers, water purification, medical
apparatus - Food beverage filling & liquid transfer
- Solar water system
- Any other pressurization system
Installation
Materials:
- Diaphragm pump with related accessories
- (At least) pieces of flexible, reinforced hose piping, with
collapsing strength of twice the inlet collapsing pressure (hose
must be minimum 1/2 ID) - Stainless steel hose clamps and screws
- Screws to fasten the pump to the mounting surface
- 1 electrical cut off switch
- 1 fuse
- 1 screwdriver
- 1 strong cutting implement for tubing (if desired)
- Teflon tape or sealant
Setup:
- Mount the pump in a dry and well-ventilated area, on a flat
surface. - Connect the pump to the water supply using flexible, reinforced
hose piping. - Connect the pump to the outlet using flexible, reinforced hose
piping. - Fasten the pump to the mounting surface using screws.
- Install an electrical cut off switch and a fuse for
safety. - If desired, use a strong cutting implement to cut tubing to
appropriate length. - Use Teflon tape or sealant on all threaded connections to
prevent leaks.
Notes:
- Please consult a professional technician if the bypass needs
adjustment. Improper adjustment of the bypass may damage the
pump. - Please follow the instruction manual to install the product.
Any action outside what is recommended in this manual may bring
damage to the pump. Any inappropriate installation or operation
that causes pump damage is not covered by warranty.
Diaphragm Pump Instruction Manual
Diaphragm Pump
NMDP42-G35-55-12
NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to contact us: [email protected]
This is the original instruction,Please read all manual instructions carefully before operating.VEVOR reserves clear interpretation of our user manual. The
appearance of the product shall be subject to the product you received.Please forgive us that we won’t inform you again if there is any
technology or software updates on our product. 01
An economical workhorse, the 42 Series is engineered for flexibility. The 4-chamber series are our Heavy-Duty water pump. It provides
high-volume water flow with reduced pump cycling, thanks to the large four-chamber diaphragm. With the on- demand switch, 3.5 GPM, and 55 PSI, the 42 Series will meet your special requirements
with positive predictable performance. With a built-in bypass function, the 42 Series can reduce rapid cycling and allow water to
flow back from the outlet side to the inlet side of the pump. We also offer a variety of easy-connect fittings and filters.
PRODUCT SPECICATIONS
Propey
Specications
Rated Voltage
12V
Rated Pressure Number of Chamber 4 PCS
55 PSI 4 PCS
Max. Flow Inlet/Outlet Diameter
3.5 GPM 1/2″ MNPT
An incredible feature list, high-quality components, plus amazing performance. The four-chamber high-volume design, driven by a heavy-duty motor produces flow rates of 3.5 GPM, capable of self-priming up to 6 vertical feet, and can run dry, making it the price-to-performance leader. This pump also offers a variety of easy-connect fittings and filters.
FEATURES
c4 -chamber diaphragm pump c5min on 10min off cBypass: reduces cycling cRun dry capable for normal workloads cAutomatic: controlled by pressure switch cIndustry-standard mounting pattern cSelf priming cQuiet Operation cIgnition protected
02
APPLICATIONS
cYacht/RV/caravan pressurized water system cSprayer fixtures (vehicle-mounted sprayers,electric sprayers) cCleaning machines Humidifiers water purification,medical apparatus cFood beverage filling & liquid transfer cSolar water system cAny other pressurization system
INSTALLATION
Materials
1.diaphragm pump with related accessories 2.(at least) pieces of flexible, reinforced hose piping, with collapsing strength of twice the inlet collapsing pressure(hose must be minimum 1/2″ID) 3.stainless steel hose clamps and screws 4.screws to fasten the pump to the mounting surface
1 electrical cut off switch 1 fuse 1 screwdriver 1 strong cutting implement for tubing (if desired)Teflon tape or sealant
Setup
1. The pump may be mounted in any position. If mounted vertically, the pump head should be in the down position to avoid leakage into the motor casing in the event of a malfunction. 2. Secure the feet, but do not compress them. Over tightening the securing screws may reduce their ability to dissipate noise and vibration. 3.The inlet and outlet hoses must be 1/2″ (13 mm) ID reinforced hoses. The diameter of branch and individual supply lines from the outlet should be no smaller than 3/8″ (10 mm). 4. Plumb the system using high pressure (2 x pump rating), braided, flexible tubing to minimize vibration/noise. 5.Do not apply inlet pressure in excess of 30psi. In general, try to avoid any inlet pressure completely. 6.Avoid any kinks or fittings which could ca use excessive restrictions. 7.Strainer should be attached to the inlet side. 8.The fittings must be secured to avoid leakage 9.Use clamps at both ends of the hose to prevent air leaks into the water line. 10. If a check valve is installed in the plumbing, it must have a cracking pressure of no more than 2 psi. 11. If applying a sealer or plumbing tape, be careful to not over tighten, as they may be sucked into
03
12. This pump should be wired on its own dedicated circuit. Connect the positive lead (red) to the positive terminal of your battery and the negative wire(black) to the negative terminal of your battery. 13. In an easily accessible location, install a switch to control electricity to the pump. Turn the pump off when not used for extended periods or when the tank is empty. 14. The electrical circuit should be protected with an over-current protection device(fuse) in the positive lead. This pump requires a 15 amp fuse. 15. The pump circuit should not include any other electrical loads. 16. As the water supply pump is non-essential, reference the wire Chart under the electrical information. Be sure to have the correct wire sizing for the length of wire you are using. 17.After installation, check the voltage at the pump motor. Voltage should be checked when the pump is operating. Full voltage must be available at the pump motor at times.
Notes
1. Flexible potable water hose or PEX tubing is recommended instead of rigid piping at the pump. If you choose to use rigid piping, provide a short length of hose between the pipe and the pump to avoid noise and vibration. 2. We do not recommend the use of metal fittings. When possible, use the provided plastic fittings. 3. Do not adjust the bypass personally without the help of a technician. 4. Lack of sanitizing and maintenance is one of the main reasons for the underperformance of the pump. Please do maintenance and winterize the pump at appropriate times, especially before and after a period of storage.
ABOUT THE BYPASS
Please consult a professional technician in case the bypass needs adjustment. Improper adjustment of the bypass may damage the pump. The bypass comes preset for optimal operation of the pump. If your application calls for a different setting for the bypass, you may change it yourself. Carefully tighten the screw to increase or loosen the screw to decrease the minimum operating pressure of the bypass.
CAUTION
Please do follow the instruction manual to install the product. Any action outside what is recommended in this manual may bring damage to the pump. Any inappropriate installation or operation that causes the pump damage is not covered by warranty.
04
ACCESSORIES
Item Hose Adapter
Filter Hexagon Bolt Sealing Tape
Quantity 2 1 1 1
EXPLODED VIEWS
KEY
Description
Quantity
A
Pump Head Assembly
1
B
Valve Assembly
1
C
Diaphragm Assembly
1
D
Motor Assembly
1
1
Pressure Switch
1
2
Diaphragm of Pressure Switch 1
3
Pump Head
1
4
Diaphragm
1
5
Rubber Feet
1
6
Motor
1
05
PRODUCT SIZE
TROUBLESHOOTING
PULSATING FLOW– PUMP CYCLES ON AND OFF ·Check lines for kinks. ·Plumbing lines or fittings may be too small. ·Clean faucets and filters. ·Check fitting tightness for air leaks. FAILURE TO PRIME BUT MOTOR OPERATES – NO PUMP DISCHARGE ·Restricted in take or discharge line · Air leak in intake line. ·Punctured pump diaphragm ·The initial amp supply is not enough to sufficiently start the motor. ·Debris clogs in the valves ·Crack in the pump housing.
MOTOR FAILS TO TURN ON · Loose or improper wiring. ·The pump circuit has no power. · Blown fuse. ·Failed pressure switch. ·Defective motor.
PUMP FAILS TO TURN OFF AFTER ALL FIXTURES ARE CLOSED · Punctured diaphragm. ·Discharge line leak Defective pressure switch. ·Insufficient voltage. ·Clogged valves in the pump head. LOW FLOW AND PRESSURE · Air leak at the pump intake. ·AccumuIation of debris inside pump or plumbing. ·Worn pump bearing (possibly accompanied by loud noise). ·Punctured diaphragm ·Defective motor.
06
NOISY · Check if the mounting feet are compressed too tightly. ·ls the mounting surface flexible? If so, it may be adding noise. ·Check for loose head/screws. ·If the pump is plumbed with rigid pipe,then it may transmit noise more easily.
USE THE FOLLOWING PROCESS TO ADJUST SHUT-OFF AND BY-PASS PRESSURES
1. Install the pump as in picture 1.
ADJUSTING THE BYPASS VALVE AND PRESSURE SWITCH TIP: Bypass adjustment should be performed by a professional
technician using a proper gauge and equipment. Without the proper equipment, you could mis-adjust the valve or switch causing the pump to work improperly (see Caution below). About the Bypass Valve The pump uses a spring-loaded bypass valve to maintain smooth performance as water demands rise and fall. When a faucet is turned on the pump is providing full water flow, so the bypass valve is closed. But when there is little to no water demand, the bypass valve opens to allow water to flow back from the outlet side to the inlet side, keeping a steady flow of water within the pump with almost no cycling.
ADJUSTING THE PUMP’S SHUT-OFF PRESSURE:(1)
° To raise the shut-off pressure, use a 2mm Allen wrench to turn the pressure switch screw clockwise to the desired pressure. °To lower the shut-off pressure, use a 2mm Allen wrench to turn the pressure switch screw counter-clockwise to the desired pressure.
ADJUSTING THE BYPASS:c2 °To raise the pressure at which the bypass starts and raise the full bypass pressure, use a 2mm Allen wrench to turn the bypass screw clockwise to the desired pressure. °To lower the pressure at which the bypass starts and lower the full bypass pressure, use a 2mm Allen wrench to turn the bypass screw counter-clockwise to the desired pressure.
07
CAUTION: The pressure setting for full bypass must be at least 8psi higher than the shut-off pressure of the pump. If the switch and bypass is adjusted too closely, the bypass and switch shut-off can overlap and the pump will not shut off.
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and (2)thisdevice must accept any interferenc ereceived , including interference that may cause undesired operation. This product is subject to the provision of European Directive 2012/19/EC. The symbol showing a wheelie bin crossed through indicates that the product requires separate refuse collection in the European Union. This applies to the product and all accessories marked with this symbol. Products marked as such may not be discarded with normal domestic waste, but must be taken to a collection point for recycling electrical and electronic devices
*There are any minor changes to the numbers included in the user manual without prior notice.
Manufacturer: Xiamen Newmao Pump Co., Ltd Add2nd Pak of Zone , Floor 3, Main Building of Huaxin General Facto;, No. 216, Huanzhu Road, Qiaoying Street, Jimei District,Xiamen
08
E-mail: [email protected]