A16R All New Industrial Clamp Multimeter
A16R Industrial Clamp Multimeter User Manual
Product Information
The A16R Industrial Clamp Multimeter is a versatile tool
designed for measuring AC/DC voltage, resistance, continuity,
frequency, and current. It features a 3 3/4 digit large scale LCD
display with a display count of 4000 and a measuring rate of 1.5
times per second. The meter has overload protection of
750Vrms//1000Vdc and input impedance of 1M // less than 100pF. It
is powered by a 9V alkaline battery that has a life of up to 100
hours.
The A16R Industrial Clamp Multimeter is compliant with EU
directives, and the jaw is CAT.IV.600V protected with respect to
earth. The meter also features tactile barriers for hand guards to
ensure safe operation.
Product Usage Instructions
Safety Information: Always follow the
instructions provided for safe operation and service of the Meter.
Failure to observe warnings can result in severe injury or
death.
Off/On: To power on the meter, press any button
(except Hold button) and switch the rotary knob. The meter will
automatically power off after approximately 30 minutes of
inactivity. To disable auto power off, press any button (except
Hold button) and switch the rotary knob.
AC/DC Voltage Measurement: Use the AC V/DC V
function to measure voltage. Ensure that the equipment being
measured is protected by double or reinforced insulation. For DC
measurement, connect the red test lead to the positive (+) terminal
and the black test lead to the negative (-) terminal. For AC
measurement, connect the test leads to the phase line and neutral
line.
Resistance & Continuity: Use the Resistance
and Continuity function to measure resistance and continuity. The
meter has overload protection of 600Vrms and a maximum open circuit
voltage of 3V. The internal sound will activate if the resistance
of the circuit under test is less than 30 approximately.
AC/DC Current Measurement: Use the AC A/DC A
function to measure current. For DC measurement, open the jaw and
place it around the conductor being measured. For AC measurement,
ensure that the jaw is CAT.IV.600V protected with respect to earth.
Do not hold the meter across the tactile barrier for hand
guard.
Frequency Measurement: Use the Hz function to
measure frequency.
Data Hold: Use the Data Hold function to freeze
the displayed value on the LCD display.
Min/Max Hold: Use the Min/Max Hold function to
save and display the minimum and maximum values measured. Press and
hold the MIN/MAX button to return to normal operation.
Peak Hold: Use the Peak Hold function to save
and display the peak maximum and minimum values measured. Press and
hold the PEAK button for 3 seconds to calibrate the meter itself
for accurate measurement. Press and hold PEAK to return to normal
operation.
Back Light: The back light will automatically
turn off after 60 seconds of inactivity.
Battery Replacement: Replace the 9V alkaline
battery when “Replace battery” is displayed or flashes when
pressing a button.
A16R
User Manual /
EN All New Industrial Clamp Multimeter TC SC JP RU
YEAR S
LIMITE D WARRAN TY
A16R
EN
Read First
Safety Information
To ensure safe operation and service of the Meter, follow these instructions. Failure to observe warnings can result in severe injury or death.
WARNING
· Avoid working alone so assistance can be rendered. · Do not use test leads or the Meter if they look damaged. · Do not use the Meter if the Meter is not operating properly
or if it is wet. · Use the Meter only as specified in the Instruction card or
the protection by the Meter might be impaired. · Use extreme caution when working around bare
conductors or bus bar. Contact with the conductor could result in electric shock. · Use caution with voltages above 30V ac rms, or 60V dc. These voltages pose a shock hazard. · To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the low battery indicator ( ) appears. Symbols as marked on the Meter and Instruction card
Risk of electric shock
See instruction card
DC measurement
Equipment protected by double or reinforced insulation
Battery
Earth
AC measurement
Conforms to EU directives
Caution If the meter is used in the vicinity of equipment which generates electromagnetic interference, the display may become unstable or the measurements show may be subject to large errors.
1
A16R
EN
Off / On
Auto Power Off
30min
Auto Power Off disable : Press buttons (except Hold button) than switch the rotary knob to power on the Meter.
AC V / DC V
2
A16R
EN
Resistance
Continuity
3
A16R
AC A / DC A
EN
CAT.IV.600V with respect to earth for the jaw.
Tactile Barrier for hand guard. Do not hold the meter across the Barrier
Hz
4
A16R
EN
Zero
2 REL: Meter save the displayed offset value after press the ZERO button first time. The LCD is displaying the relative value.
3 REL (flashing): Meter saved the offset value. Present value is displaying
1 Normal : Press and hold ZERO for 2 sec to return to normal operation and cancel the offset value.
Data Hold
190A
5
A16R
EN
Min / Max Hold
2 MAX: Meter is saving the maximum and minimum value. Maximum value is displayed.
3 MIN: Meter is saving the maxi mum and minimum value. Minimum value is displayed.
4 MAX MIN (flashing): Meter is saving the maximum and minimum values. Present value is displayed.
1 Normal : Press and hold MIN MAX to return to normal operation.
Battery Replacement
Replace battery : ” ” is displayed or displays ” ” a flash when press button.
6
A16R
EN
Peak Hold
2 P MAX : Meter is saving the peak maximum and minimum value. Peak maximum value is displayed.
3 P MIN : Meter is saving the peak maximum and minimum value. Peak minimum value is displayed.
4 CAL : Press and hold PEAK button 3 sec to calibrate the Meter itself for accurate measurement.
1 Normal : Press and hold PEAK to return to normal operation.
Back Light
Back light Automatic off after 60 seconds.
7
A16R
EN
Specifications 1-1 General Specifications
LCD display digits : 3 3/4 digit large scale LCD readout. Display count : 4000 counts. Measuring rate : 1.5 times / sec. Overrange display : “OL” is displayed for “” functions, shows the real value for “A” and “V” function. Automatic power off time : Approximately 30 minutes after power on. Low battery indicator :
is displayed. Replace the battery when the indicator appears in the display. Power requirement : 9V battery. Battery life : ALKALINE 9V 100 hours.
1-2 Environmental Conditions
Indoor Use. Calibration : One year calibration cycle. Operating temperature : 0°C ~ 30°C ( 80% RH) 30°C ~ 40°C ( 75% RH) 40°C ~ 50°C ( 45%RH) Storage temperature : -20 to +60°C, 0 to 80% RH (batteries not fitted). Overvoltage category : IEC 61010-1 600V CAT.IV. CAT.IV equipment of OVERVOLTAGE CATRGORY IV is for use at the origin of the installations. Note examples include electricity meters and primary over-current protection equipment. Operating altitude : 2000m (6562 ft) Conductor Size : 51mm diameter. Pollution degree : 2 EMC : EN 61326-1 Shock vibration : Sinusoidal vibration per MIL-T- 28800E (5 ~ 55 Hz, 3g maximum).
8
A16R
EN
1-3 Electrical Specifications
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C < 80%RH. Temperature coefficient : 0.2 x (Specified accuracy) / °C,< 18°C, > 28°C .
Voltage
Function
V V
Range
0~400.0Vrms 400~750Vrms
0~400.0 V 400~1000 V
Accuracy ±(1.0%+ 5 dgt) *1 50Hz ~ 500Hz *2
±(0.7% + 2 dgt)
Overload protection : 750Vrms//1000Vdc
Input impedance :1M // less than 100pF.
AC Conversion Type :
A16R :
*1 : Reading less than 15% of full scale (4000 digits) is needed to add 4 digits and the settling time will increase. *2 : AC Conversions are ac-acoupled, true rms responding, calibrated to the rms value of a sine wave input. Accuracies are given for sine wave at full scale and non-sine wave below half scale. For non-sine wave add the following Crest Factor corrections : For Crest Factor of 1.4 to 2.0, add 1.0% to accuracy. For Crest Factor of 2.0 to 2.5, add 2.5% to accuracy. For Crest Factor of 2.5 to 3.0, add 4.0% to accuracy. CF 2 @ 600A, 600V 1.5 @ 1000A, 750V
9
A16R
EN
Resistance & Continuity
Function
Range 400.0
Accuracy ±(1% + 3 dgt)
Overload protection : 600 Vrms Max. open circuit voltage : 3V Continuity check : Internal sounds activates if the resistance of the circuit under test is less than 30 approximately.
AC Current
Function
A
(50~400Hz)
A
(50~200Hz)
Range 0~200.0A 200.0~400.0A 400~1000A
Accuracy ±(1.9% + 3 Amp) ±(1.9% + 2 Amp) ±(2.9% + 5 Amp)
Overload protection : 1000 Arms AC Conversion Type and additional accuracy is same as AC Voltage. *2 Position Error : ±1% of reading.
DC Current
Function
A
Range 0~200.0A 200.0~400.0A 400~1000A
Accuracy ±(2.9% + 3 Amp) ±(1.9% + 2 Amp) ±(2.9% + 5 Amp)
Overload protection : 1000 Arms Position Error : ±1% of reading. Addition error according to remanence: 1% max. of current crest.
Auto Power Off (APO) The meter will automatically shut itself off after approximately 30 minutes after power on.
10
A16R
EN
Frequency : Hz
Function 20~400Hz
Range 1Hz
Accuracy ±(0.1% + 2 dgt)
Overload protection : 1000 Arms. Sensitivity : 3 Arms for ACA (A%) (>400Hz Unspecified) Peak Hold : ± (3% + 20dgt) *>750Vpeak Unspecified. *>800Apeak Unspecified. Min/Max Hold : add ± 15 dgt to accuracy for ACA, add ±15dgt and remanence to accuracy for DCA. * Automatically switch to the low resolution range at Peak Hold and MIN MAX Hold.
Maintenance
Do not attempt to repair this Meter. It contains no userserviceable parts. Repair or serving should only be performed by qualified personal.
Cleaning
Periodically wipe the case with a dry cloth and detergent do not use abrasives or solvents.
11
A16R
EN
Limited Warranty
This Meter is warranted to the original purchaser against defects in material and workmanship for 3 year from the date of purchase. During this warranty period, manufacturer will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction.
This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling.
Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you.
12
A16R
TC
· · · ·
·
· 30 60
· ( )
13
A16R
TC
/
30min
( )
/
14
A16R
TC
15
A16R
/
TC
CAT.IV. 600
16
A16R
TC
2 REL LCD
3 REL( ) 1
190A
17
A16R
TC
/
2 4 3 ( )
1
18
A16R
TC
3
2 P
3 P
4 CAL 3
1
60
19
A16R
TC
1-1
LCD 3 3/4 LCD 4000 1.5 OLAV 30 9 9 100
1-2
0° C ~ 30° C ( 80% ) 30° C ~ 40° C ( 75% ) 40° C ~ 50° C ( 45% ) -20~+60° C0~80% ( ) IEC 61010-1 600V CAT. . CAT. 2000 (6562 ) 51 2 EMCEN61326-1 MIL-T-28800E (5 ~ 55 , 3g)
20
A16R
TC
1-3
±(% + ) 23 ° C ± 5 ° C < 80% 0.2 ( ) / ° C< 18° C > 28° C
V V
0~400.0 400~750
0~400.0 400~1000
±(1.0%+ 5 )*1 50 ~ 500 *2
±(0.7% + 2 )
750 //1000
1M// 100pF
A16R :
*14000 15% 4 *2 1.4 2.0 1.0% 2.0 2.5 2.5% 2.5 3.0 4.0% CF2@600 600 1.5@1000 750
21
A16R
TC
400.0
±(1.0%+ 3 )
600 3 30
A
(50~400 )
A
(50~400 )
0 200.0 200.0 400.0
400 1000
±(1.9%+ 3 ) ±(1.9%+2 ) ±(2.9%+ 5 )
1000Arms *2 ±1%
A
0 200.0 200.0 400.0
400 1000
±(2.9%+ 3 ) ±(1.9%+2 ) ±(2.9%+ 5 )
1000Arms ±1% 1%
(APO) 30
22
A16R
TC
20 400
1
±(0.1%+ 2 )
1000 Arms A%3 Arms>400 ± (3% + 20 ) *>750 *>800 / ±15 ±15 *
23
A16R
TC
24
A16R
SC
· · · ·
·
· 30 60
· ( )
25
A16R
SC
/
30min
( )
/
26
A16R
SC
27
A16R
/
SC
CAT.IV. 600
28
A16R
SC
2 REL LCD
3 REL( ) 1
190A
29
A16R
SC
/
2 4 3 ( )
1
30
A16R
SC
3
2 P
3 P
4 CAL 3
1
60
31
A16R
SC
1-1
LCD 3 3/4 LCD 4000 1.5 OLAV 30 9 9 100
1-2
0° C ~ 30° C ( 80% ) 30° C ~ 40° C ( 75% ) 40° C ~ 50° C ( 45% ) -20~+60° C0~80% ( ) IEC 61010-1 600V CAT. . CAT. 2000 (6562 ) 51 2 EMCEN61326-1 MIL-T-28800E (5 ~ 55 , 3g)
32
A16R
SC
1-3
±(% + ) 23 ° C ± 5 ° C < 80% 0.2 ( ) / ° C< 18° C > 28° C
V V
0~400.0 400~750
0~400.0 400~1000
±(1.0%+ 5 )*1 50 ~ 500 *2
±(0.7% + 2 )
750 //1000
1M// 100pF
A16R :
*14000 15% 4 *2 1.4 2.0 1.0% 2.0 2.5 2.5% 2.5 3.0 4.0% CF2@600 600 1.5@1000 750
33
A16R
SC
400.0
±(1.0%+ 3 )
600 3 30
A
(50~400 )
A
(50~400 )
0 200.0 200.0 400.0
400 1000
±(1.9%+ 3 ) ±(1.9%+2 ) ±(2.9%+ 5 )
1000Arms *2 ±1%
A
0 200.0 200.0 400.0
400 1000
±(2.9%+ 3 ) ±(1.9%+2 ) ±(2.9%+ 5 )
1000Arms ±1% 1%
(APO) 30
34
A16R
SC
20 400
1
±(0.1%+ 2 )
1000 Arms A%3 Arms>400 ± (3% + 20 ) *>750 *>800 / ±15 ±15 *
35
A16R
SC
36
A16R
JP
· ·
·
·
· · · 30 V acrms 60Vdc · ( )
DC
AC
EU
37
A16R
JP
/
30min
AC V / DC V
38
A16R
JP
39
A16R
AC A / DC A
JP
CAT.IV..600V
Hz ( )
40
A16R
JP
2 RELZERO LCD
3 REL
1 2
190A
41
A16R
JP
/
2 (Max)
4 (MIN)
3 (MAX MIN)
1 MIN MAX
” ” ”
42
A16R
JP
3
2 PMAX:
3 PMIN:
4 CAL( ) : PEAK 3
1 PEAK
60
43
A16R
JP
1-1
LCD 33/4 LCD 4000 1.5 / “” “OL” “A” “V” 30 9V 9V100
1-2
1 0° C 30 80 RH 30 40 75 RH 40 50 45 RH -20 + 600 80 RH IEC 61010-1 600V CAT. . 2000m6562 51mm 2 EMCEN61326-1 MIL-T-28800E 5 55 Hz 3g
44
A16R
JP
1-3
23 ±5 <80 RH ± +
:
0.2 x/<18° C> 28
V V
0~400.0Vrms 400~750Vrms
0~400.0 V 400~1000 V
±(1.0%+ 5 dgt) *1 50Hz ~ 500Hz *2
±(0.7% + 2 dgt)
750Vrms // 1000Vdc 1M// 100pF
AC
A16R :
*114 4000 15 *2AC AC rms rms : 1.4 2.0 1.0 2.0 2.5 2.5 2.5 3.0 4.0 CF 2 @ 600A600V 1.5 @ 1000A750V
45
A16R
400.0
JP
±(1% + 3 dgt)
600 Vrms 3V 30
AC
A
(50~400Hz)
A
(50~200Hz)
0~200.0A 200.0~400.0A 400~1000A
±(1.9% + 3 Amp) ±(1.9% + 2 Amp) ±(2.9% + 5 Amp)
1000 *2 ±1
DC
A
0~200.0A 200.0~400.0A 400~1000A
±(2.9% + 3 Amp) ±(1.9% + 2 Amp) ±(2.9% + 5 Amp)
1000 ±1 1
(APO)
30
46
A16R
Hz
20~400Hz
1Hz
JP
±(0.1% + 2 dgt)
1000 ACA 3 A%> 400Hz ±3 + 20dgt *>750Vpeak *>800Apeak / ACA ±15 dgt DCA ±15dgt * MINMAX
47
A16R
JP
3
48
A16R
RU
, . .
· , . · -,
· -, ,
. · – ,
, . · . . · 30 rms 60 . . · , , , ( ) .
, – .
.
!
, , .
49
A16R
RU
/
–
30min
( «»), , .
/
50
A16R
RU
51
A16R
/
RU
IV. 600
52
A16R
RU
2 REL«REL»: «ZERO» . – .
3 «REL» (): . .
1 «Normal»: «ZERO» 2 , .
190A
53
A16R
RU
/
2 «MAX»: . .
3 «MIN»: . .
4 «MAX / MIN» (): . .
1 «Normal»: «MAX / MIN», .
: ” ” ”
54
A16R
RU
> 3
2 «PMAX»: . – .
3 «PMIN»: . – .
4 «CAL»: «PEAK» 3
. 1 «Normal»: «PEAK», .
60 .
55
A16R
RU
1-1
-:3 3/4 – . : 4000 . : 1,5 / . : «OL» «», «A» «V». : 30 . : . . : 9 : 9V 100
1-2 .
: – . : 0° C ~ 30° C ( 80%)
30° C ~ 40° C ( 75%)
40° C ~ 50° C ( 45%)
: -20 + 60° C, 0 80% ( ). : IEC 61010-1 600V IV. IV. – IV . , . : 2000 (6562 ) : 51 . : 2 EMC: EN 61326-1 : MIL-T-28800E (5 ~ 55 , 3g).
56
A16R
RU
1-3
± (% + ) 23 °C ± 5 °C, < 80% . : 0,2 x ( ) / °C, < 18 °C, > 28 °C
0~400.0rms 400~750rms
0~400.0 400~1000
±(1.0%+ 5 .) *1
50 ~ 500 *2
±(0.7% + 2 .)
:
750rms // 1000
: 1 // 100
.
:
A16R :
*1 15% (4000 ), 4 . *2 , , . – . : 1,4 2,0, 1,0% . 2,0 2,5 2,5% . 2,5 3,0 4,0% . 2 600//600A 1,5 1000, 750
57
A16R
RU
400.0
±(1% + 3 .)
: 600 rms . : 3 : , 30 .
A
(50~400)
A
(50~200)
0~200.0A 200.0~400.0A 400~1000A
±(1.9% + 3 ) ±(1.9% + 2 ) ±(2.9% + 5 )
: 1000 Arms , . *2 : ± 1% .
A
0~200.0A 200.0~400.0A 400~1000A
±(2.9% + 3 ) ±(1.9% + 2 ) ±(2.9% + 5 )
: 1000 Arms : ± 1% . : 1% . .
(«APO»)
30 .
58
A16R
RU
:
20~400
1
±(0.1% + 2 .)
: 1000 Arms : 3 Arm ACA (A%) (> 400 ) : ± (3% + 20 .) *>750 . *>800 A . /: ± 15 . ACA, ± 15 . DCA. * «-» « . .».
-. , . .
. .
59
A16R
RU
3 . , , , , .
, , , , , , , .
, , , , , . , , , . , .
60
www.appatech.com
APAC MGL APPA Corporation
[email protected] Flat 4-1, 4/F, No. 35, Section 3 Minquan East Road, Taipei, Taiwan Tel: +886 2-2508-0877
400-099-1987 [email protected]
700019906