SENNEHISER HMD 26-II-600-S Broadcast Headset

In the box

Switching AcitveGard™

Wearing the headset


Single-sided listening

Replacing the ear pads
Accessories

Replacing the headband

Cleaning

Specifications
HMD series
| Headphones | HMD 26-II-600 | HMD 26-II-600S | HMD 26-II-100 |
| Transducer principle | dynamic, closed | ||
| Ear coupling | supra-aural | ||
| Frequency response | 20 to 18,000 Hz | ||
| Impedance | 300 Ω mono/ 600 Ω stereo | 600 Ω mono | 50 Ω mono/ 100 Ω stereo |
| Characteristic SPL ActiveGard™ switched on: switched off: | 105 dB SPL at 1 kHz, 1 mW | ||
| 107 dB SPL at 1 kHz, 1 V | 115 dB SPL at 1 kHz, 1 V | ||
| Max. SPL ActiveGard™ switched on: switched off: | 105 dB SPL at 1 kHz, 1 mW | ||
| 127 dB SPL at 1 kHz, 200 mW | 128 dB SPL at 1 kHz, 200 mW | ||
| THD | < 0,5 % at 1 kHz | ||
| Contact pressure | approx. 3.9 N | approx. 4.0 N | approx. 3.9 N |
| Microphone | |
| Type | BMD 424 |
| Transducer principle | dynamic, noise-compensating, super-cardioid |
| Frequency response | 40 to 16,000 Hz |
| Output voltage | 0.4 mV/Pa at 1 kHz |
| Impedance | 300 Ω |
| General data | |||
| Temperature range operation: storage: | -15 ˚C to 55 ˚C -55 ˚C to 70 ˚C | ||
| Weight without cable | approx. 200 g | approx. 130 g | approx. 200 g |
HME series
| Headphones | HME 26-II-600(4)* | HME 26-II-100(4)*-P48 |
| Transducer principle | dynamic, closed | |
| Ear coupling | supra-aural | |
| Frequency response | 20 to 18,000 Hz | |
| Impedance | 300 Ω mono/ 600 Ω stereo | 50 Ω mono/ 100 Ω stereo |
| Characteristic SPL ActiveGard™ switched on: switched off: | 105 dB SPL at 1 kHz, 1 mW | |
| 107 dB SPL at 1 kHz, 1 V | 115 dB SPL at 1 kHz, 1 V | |
| Max. SPL ActiveGard™ switched on: switched off: | 105 dB SPL at 1 kHz, 1 mW | |
| 127 dB SPL at 1 kHz, 200 mW | 128 dB SPL at 1 kHz, 200 mW | |
| THD | < 0.5 % at 1 kHz | |
| Contact pressure | approx. 3.9 N | |
| Microphone | |
| Type | BKE 4-2 | BKE 4-4 – only in variants (*4) |
| Transducer principle | BKE 4-2: pre-polarized condenser microphone, omni-directional |
| BKE 4-4: pre-polarized condenser microphone, cardioid | |
| Frequency response | 40 to 20,000 Hz |
| Output voltage | 4 mV/Pa ± 2.5 dB |
| Terminating impedance | min. 4.7 kΩ |
| Max SPL | 150 dB at 1 kHz, 0.5% THD |
| Supply Voltage | 5 to 15 V DC |
| General data | |
| Temperature range operation: storage: | -15 ˚C to 55 ˚C -55 ˚C to 70 ˚C |
| Weight without cable | approx. 200 g |