Eph Controls Pr092k7 Rf Cylinder Thermostat Instruction Manual

PR092K7 RF Cylinder Thermostat

Product Information

RFC – RF Cylinder Thermostat

The RFC – RF Cylinder Thermostat is a wireless enabled
thermostat designed for controlling the temperature of a cylinder.
It comes with various features and functions to ensure accurate
temperature control and ease of use.

Factory Default Settings

  • Temperature indicator: Off
  • Switching differential: Not specified
  • In-built frost protection: Not specified
  • Keypad lock: Off

Specifications

  • Power Supply: Not specified
  • Power consumption: Not specified
  • Battery replacement: Required (batteries provided)
  • Temp. Control Range: Not specified
  • Dimensions: Not specified
  • Temp. sensor: Not specified
  • Temp. indication: Not specified

Button / Symbol Description

  • Wireless symbol: Indicates wireless connectivity
  • Heating ON symbol: Indicates that the heating is turned on
  • Water temperature: Indicates the current water temperature
  • Battery low symbol: Indicates low battery level
  • Boost button: Used for activating the boost function
  • Set point handwheel: Used for setting the desired
    temperature
  • Code button: Not specified
  • Reset button: Used for resetting the thermostat

Product Usage Instructions

Prior Setup

Before setting up the thermostat, ensure that all required
settings are completed as described in the user manual.

CAUTION: Only qualified electricians or authorized service staff
are permitted to open the thermostat.

Ensure that the wireless enabled thermostat is installed at
least 1 meter away from any metallic object, television, radio, or
wireless internet transmitter.

Mounting

The thermostat can be mounted in various ways:

  1. Recessed conduit boxes
  2. Surface mounting boxes
  3. Directly on walls

Installation

  1. Press the button on the bottom of the thermostat to detach the
    front housing from the baseplate.
  2. Insert the provided batteries into the thermostat.
  3. Press the reset button on the PCB to initiate the reset
    process.
  4. Rotate the hand wheel clockwise until ‘YES’ appears on the
    screen.
  5. Press the hand wheel once to confirm the setting.
  6. The thermostat has now been reset, and the current temperature
    will appear on the screen.

Boost Function

To boost the heating for a specific duration:

  • Press the boost button once, twice, or three times to boost the
    heating for 1, 2, or 3 hours respectively.
  • ‘+1H’, ‘+2H’, or ‘+3H’ will appear on the screen to indicate
    the boost duration.
  • The boost function will override the programmer if it is timed
    to be Off.

Lock Function

To lock the thermostat:

  • Press the hand wheel for 10 seconds.
  • The keypad symbol will appear on the screen, indicating that
    the thermostat is locked.

To unlock the thermostat:

  • Press the hand wheel for 10 seconds.
  • The keypad symbol will disappear from the screen, indicating
    that the thermostat is unlocked.

For further assistance, please contact EPH Controls Ireland at
[email protected] or visit their website at www.ephcontrols.com. For inquiries
in the UK, contact EPH Controls UK at [email protected] or
visit their website at www.ephcontrols.co.uk.

RFC – RF Cylinder Thermostat

Page 1 of 2
Operating Instructions

Contents
1. Factory default settings 2. Specification & wiring 3. Mounting 4. Installation 5. Button / symbol description 6. Resetting the thermostat 7. Boost function 8. Lock function 9. To connect the RFC thermostat to the
R_7-RF programmer 10. To disconnect the RFC thermostat from
the R_7-RF programmer
Important: Keep this document
Prior to setting the thermostat, it is neccessary to complete all required settings described in this section.

CAUTION!
Only qualified electricians or authorised service staff are permitted to open the thermostat.
Ensure that this wireless enabled thermostat is installed 1 metre from any metalic object, television, radio or wireless internet transmitter.

1. Factory default settings

Temperature indicator:

°C

Switching differential:

5°C

In built frost protection:

5°C

Keypad lock:

Off

2. Specifications & wiring

5. Button / symbol description
Wireless symbol

Heating ON symbol

Water temperature

Battery low symbol Boost button

Power Supply: Power consumption: Battery replacement: Temp. Control Range: Dimensions: Temp. sensor: Temp. indication:

2 x AAA Alkaline Battery 50 uA Once per year 10…90°C 84 * 84 * 30mm NTC 10K Ohm @ 25°C – 1.5m probe type °C

Set point handwheel

3a Mounting of temperature sensor

Code button

ON CYLINDER: To ensure accurate control of your cylinder, the temperature sensor should be mounted on the bottom 1/3 of the cylinder. It is essential that the sensing element is in direct contact with the cylinder and that there is no insulation between it and the cylinder. 60°C is the temperature level required in order to prevent the build up of legionella bacteria. The temperature sensor can be fixed to the cylinder using the provided foil tape. ON PIPEWORK: To ensure accurate control, the temperature sensor should be mounted on the pipework as tightly as possible. It is essential that the sensing element is in direct contact with the pipework and that there is no insulation between it and the pipework. The temperature sensor can be fixed to the pipework using the provided foil tape.
3b Mounting of thermostat
The thermostat should be mounted in a position that will make reading the display conventient. The thermostat can be fitted to: 1. Recessed conduit boxes
2. Surface mounting boxes 3. Directly on walls
4. Installation

Reset button
6. Resetting the thermostat
Press the button on the bottom of the thermostat, the front housing will detach from the baseplate. Insert the batteries into the thermostat. Press the reset button on the PCB, `NO’ will flash on the screen. Rotate the hand wheel clockwise until `YES’ appears on the screen. Press the hand wheel once to confirm the setting. The thermostat has now been reset and the current temperature will appear on the screen.
7. Boost function
Press the boost button once, twice or three times to boost the heating for 1, 2 or 3 hours respectively. +1H, +2H or +3H will appear on the screen. The boost function will override the programmer if the programmer is timed to be Off.

Press the button on the bottom of the thermostat. The front housing will detach from the baseplate. Insert the batteries (provided) into the thermostat. Mount the unit as described in section 3. Ensure the cable sensor is connected to terminals Con 3 and Con 4. Offer the baseplate up to the thermostat. Snap it into position to close.

8. Lock function
To lock the thermostat, press the hand wheel for 10 seconds. The keypad symbol will appear on the screen. To unlock the thermostat, press the hand wheel for 10 seconds. The keypad symbol will disappear from the screen.

EPH Controls Ireland
[email protected] www.ephcontrols.com

EPH Controls UK
[email protected] www.ephcontrols.co.uk
20221019_RFC-Renesas(PR092K7)_OpIns_PK

RFC – RF Cylinder Thermostat

9. To connect the RF thermostat with the programmer

Lower the cover on the front of the timeswitch / programmer. Move the selector switch to the RUN position.

RUN

CLOCK SET

PROG SET

On the timeswitch / programmer, press the Wireless Connect will appear on the screen.

button for 5 seconds.

On the RFR wireless room thermostat or RFC wireless cylinder thermostat, press the Code button. This is located inside the housing on the Printed Circuit Board.

On the timeswitch / programmer, the available zones will begin to flash.

Press the

button for the zone you wish to connect the

thermostat to.

The wireless symbol appears on the screen.

The thermostat will count to 3 and then display the zone of the programmer that it is paired to.

If it is paired to the first zone it will display r1, the second zone r2 etc.

Press the wheel on the thermostat to complete the pairing process.

The timeswitch / programmer is now operating in the wireless mode. The temperature of the wireless thermostat is now displayed on the programmer. Repeat this process for the second, third and fourth zone if required.

10. To disconnect the RF thermostat with the programmer

Lower the cover on the front of the timeswitch / programmer. Move the selector switch to the RUN position.

RUN

CLOCK SET

PROG SET

On the timeswtich/ programmer, press the button for 5 seconds. This will take you into the Wireless Connect screen. Press the button for 3 seconds. This will clear all RF connections thereby disconnecting all thermostats from the timeswitch / programmer. Press the button.

Page 2 of 2
Operating Instructions