IS-45295 Alton 1 Light Wall Sconce
Product Information: This product is a fixture
that can be mounted on an outlet box. It comes with a mounting
strap for easy installation. The fixture has grounding
instructions, which can vary depending on the type of mounting
strap provided. The product also includes wire connectors for
making wire connections. The fixture can be mounted with the glass
in either an up or down position. It requires a recommended bulb,
which is not included. Product Usage Instructions:
1. Attach the mounting strap to the outlet box using the two
supplied mounting strap screws. Adjust the mounting strap to suit
the position of the fixture. 2. Grounding instructions: – For
fixtures with a mounting strap provided with a hole and two raised
dimples: – Wrap the ground wire from the outlet box around the
green ground screw and thread it into the hole. – For fixtures with
a cupped washer provided: – Attach the ground wire from the outlet
box under the cupped washer and green ground screw, and thread it
into the mounting strap. – If the fixture is provided with a ground
wire, connect it to the outlet box ground wire using a wire
connector. – Never connect the ground wire to black or white power
supply wires. 3. Make wire connections according to the reference
chart below: – Connect the black or red supply wire to: – Black
parallel cord (round & smooth) – Clear, Brown, Gold, or Black
without tracer insulated wire (other than green) with copper
conductor – Connect the white supply wire to: – White parallel cord
(square & ridged) – Clear, Brown, Gold, or Black with tracer
insulated wire (other than green) with silver conductor – Note:
When parallel wires (SPT I & SPT II) are used, the neutral wire
is square-shaped or ridged, and the other wire will be round in
shape or smooth. 4. Push the fixture to the wall and carefully
screw in the four fixture mounting screws through the holes in the
sides of the canopy. The fixture can be mounted with the glass in
the up or down position. 5. Insert the recommended bulb (not
included). 6. Set the glass down over the socket. 7. Thread the
three thumbscrews into the base as shown, making sure not to over
tighten. For further assistance, you can contact our customer
support at 866-558-5706, Monday to Friday, from 9am to 5pm EST.
CAUTION RISK OF SHOCK Disconnect Power at the main circuit breaker panel or main fuse box before starting and during the installation.
1) Attach mounting strap to outlet box using the (2) two
supplied mounting strap screws. Mounting strap can be
adjusted to suit position of fixture.
2) Grounding instructions: (See Illus. A or B).
A)
On fixtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B)
On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector.
After following the above steps. Never connect ground wire
to black or white power supply wires.
A
OUTLET BOX GROUND
WIRE CONNECTOR
FIXTURE GROUND
DIMPLES
OUTLET BOX GROUND
GREEN GROUND SCREW
GREEN GROUND SCREW
B
FIXTURE GROUND
CUPPED WASHER
We’re here to help 866-558-5706 Hrs: M-F 9am to 5pm EST
3) Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to:
Black *Parallel cord (round & smooth)
Clear, Brown, Gold or Black without tracer
Insulated wire (other than green) with copper conductor
Connect White Supply Wire to:
White *Parallel cord (square & ridged)
Clear, Brown, Gold or Black with tracer
Insulated wire (other than green) with silver conductor
*Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
Neutral Wire
4) Push fixture to wall, carefully screw in the (4) fixture mounting screws through holes in the sides of the canopy. NOTE, the fixture can be mounted with the glass in the up or down position.
5) Insert recommended bulb (not included). 6) Set glass down over socket. 7) Thread the three (3) thumbscrews into the base as shown.
(DO NOT over tighten.)
GLASS
THUMBSCREW(S)
(2)STRAP MOUNTING SCREWS
MOUNTING STRAP WITH GROUND SCREW
WIRE CONNECTOR(S)
OUTLET BOX
Date Issued: 06/15/16
(4)FIXTURE MOUNTING SCREWS
IS-45295-US
PRECAUCIÓN RIESGO DE DESCARGA ELÉCTRICA Desconecte la electricidad en el panel principal del interruptor automático o caja principal de fusibles antes de comenzar y durante la instalación.
1) Acople la correa del montaje a la caja de salida usando la (2)
dos suministrados Montaje correa de tornillos. Correa de
montaje puede ajustarse para adaptarse a la posición de la
luminaria.
2) Instrucciones para poner a tierra: (Ver Ilustraciones A o B).
A)
En artefactos donde se suministra la abrazadera de
montaje con un agujero y dos depresiones onduladas.
Envuelva el conductor de tierra de la caja de salida
alrededor del tornillo de tierra verde y atornille en el
agujero.
B)
En artefactos donde se suministra una arandela
cóncava. Fije el conductor de tierra de la caja de salida
debajo de la arandela cóncava y el tornillo de tierra
verde y enrosque en la abrazadera de montaje.
Si se suministra el artefacto con conductor de tierra. Co-
necte el conductor de tierra del artefacto al conductor de
tierra de la caja de salida con conector de tierra después
de seguir los pasos anteriores. Nunca conecte el conductor
de tierra a los alambres de alimentación eléctrica negros o
blancos.
A
TIERRA DE LA CAJA DE SALIDA
CONECTOR DE ALAMBRE
TIERRA ARTEFACTO
B
TIERRA ARTEFACTO
DEPRESIONES
TORNILLO DE TIERRA, VERDE
TIERRA DE LA CAJA DE SALIDA
TORNILLO DE TIERRA, VERDE
ARANDELA CONCAVA
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora oficial del este)
3) Haga las conexiones de alambres. No se provee conectores. Consulte la tabla de abajo para hacer las conexiones correctas y haga las conexiones omo corresponda.
Conectar el alambre de suministro negro o rojo al
Conectar el alambre de suministro blanco al
Negro
Blanco
*Cordon paralelo (redondo y liso) *Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro sin hebra identificadora
Claro, marrón, amarillio o negro con hebra identificadora
Alambre aislado (diferente del verde) Alambre aislado (diferente del
con conductor de cobre
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo (SPT I y SPT II). El alambre neutro es de forma cuadrada o estriada y el otro alambre será de forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
4) Empuje la luminaria a la pared, atornille cuidadosamente el (4) accesorio de tornillos a través de agujeros en los lados del dosel. Tenga en cuenta que el aparato puede montarse con el vidrio ni la posición hacia abajo.
5) Inserte la bombilla recomendada (no incluida). 6) Coloque el vidrio hacia abajo sobre el zócalo. 7) Enrosque los tornillos de tres 3 en la base como se muestra.
(No apriete demasiado.)
GLASS
THUMBSCREW(S)
(2)STRAP MOUNTING SCREWS
MOUNTING STRAP WITH GROUND SCREW
WIRE CONNECTOR(S)
OUTLET BOX
Date Issued: 06/15/16
(4)FIXTURE MOUNTING SCREWS
IS-45295-US
CAUTION RISK OF SHOCK Disconnect Power at the main circuit breaker panel or main fuse box before starting and during the installation.
1) Attach mounting strap to outlet box using the (2) two supplied mounting strap screws. Mounting strap can be adjusted to suit position of fixture.
2) Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to:
Connect White Supply Wire to:
Black
White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black without tracer
Clear, Brown, Gold or Black with tracer
Insulated wire (other than green) Insulated wire (other than green)
with copper conductor
with silver conductor
*Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
Neutral Wire
3) Push fixture to wall, carefully screw in the (4) fixture mounting screws through holes in the sides of the canopy. NOTE, the fixture can be mounted with the glass in the up or down position.
4) Insert recommended bulb (not included). 5) Set glass down over socket. 6) Thread the three (3) thumbscrews into the base as shown.
(DO NOT over tighten.)
GLASS
We’re here to help 866-558-5706 Hrs: M-F 9am to 5pm EST
INSTRUCTIONS For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
THUMBSCREW(S)
(2)STRAP MOUNTING SCREWS
MOUNTING STRAP WITH GROUND SCREW
WIRE CONNECTOR(S)
OUTLET BOX
Date Issued: 06/15/16
(4)FIXTURE MOUNTING SCREWS
IS-45295-CB
INSTRUCTIONS
Nous sommes là pour vous aider 866-558-5706
For Assembling and Installing Fixtures in Canada Pour L’assemblage et L’installation Au Canada
Heures : du lundi au vendredi, de 9h à 17h (heure de l’Est)
ATTENTION RISQUE DE DÉCHARGES ÉLECTRIQUES Couper le courant au niveau du panneau du disjoncteur du circuit principal ou de la boîte à fusibles principale avant de procéder à l’installation.
1) Fixer la sangle de fixation au boîte de sortie à l’aide des (2) deux vis sangle fournies. Sangle de fixation peut être ajusté en fonction de la position de l’appareil.
2) Rendre les connexions des fils. Référence tableau suivant pour les connexions correctes et fil en conséquence.
Connecter le fil noir ou rouge de la boite
Connecter le fil blanc de la boîte
A Noir
A Blanc
*Au cordon parallèle (rond et lisse) *Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou Au transparent, doré, marron, ou
noir sans fil distinctif
noir avec un til distinctif
Fil isolé (sauf fil vert) avec conducteur en cuivre
Fil isolé (sauf fil vert) avec conducteur en argent
*Remarque: Avec emploi d’un fil paralléle (SPT I et SPT II). Le fil neutre est á angles droits ou strié et l’autre fil doit étre rond ou lisse (Voir le schéma).
Fil Neutre
3) Luminaire pousser au mur, visser avec précaution dans les (4) Montage Montage de vis dans les trous dans les côtés de la canopée. Notez que l’appareil peut être monté avec le verre dans le haut ou vers le bas.
4) Insérer recommandé ampoule (non inclus). 5) Placez verre sur socket. 6) Visser les vis à ailettes trois 3 dans la base comme indiqué.
(Ne pas trop serrer.)
VERRE
VIS À OREILLES
VIS DE L’ÉTRIER DE MONTAGE SANGLE DE FIXATION AVEC VIS DE TERRE CONNECTEURS DE FIL
BOÎTE À PRISES
Date Issued: 06/15/16
(4)VIS DE FIXATION DE LUMINAIRE
IS-45295-CB