M27086EN Transtek Body Fat Analyzer GBF-2008-B1
Product Information
Product Name: Transtek Body Fat Analyzer
GBF-2008-B1
Manufacturer: ZHONGSHAN TRANSTEK ELECTRONICS
CO., LTD
Manufacturer Address: 23, Jin’an Road,
Minzhong, Zhongshan, 528441, Guangdong, China
Model Number: GBF-2008-B1 (27086)
Made in: China
IP Rating: IP21
Revision Number: M27086-M-Rev.0-12.21
Product Usage Instructions
- Please read the user manual carefully and thoroughly before
using the Transtek Body Fat Analyzer GBF-2008-B1. - Ensure the safe usage of this product by following the safety
and usage information provided. - Keep the user manual for future reference in case of any
problems.
Table of Contents
- Safety Information
- Tips
- Overview
- Initial Start-Up
- Start Measuring
- Manage Your Health
- Troubleshooting
- Specifications
- Maintenance
- Warranty
Safety Information
The safety information section provides important guidelines for
the safe usage of the Transtek Body Fat Analyzer GBF-2008-B1. It is
recommended to carefully read and follow these instructions to
avoid any potential risks or harm.
Tips
The tips section provides additional useful information and
recommendations for optimal usage of the product. It is advised to
go through these tips to enhance your experience with the Transtek
Body Fat Analyzer GBF-2008-B1.
Overview
The overview section provides details about the device
components and the LED display of the Transtek Body Fat Analyzer
GBF-2008-B1. Refer to this section to familiarize yourself with the
different parts and features of the product.
Initial Start-Up
- Follow the general instructions provided in this section to
ensure a proper start-up of the Transtek Body Fat Analyzer
GBF-2008-B1. - Insert the batteries as instructed to power on the device.
- Install the designated app and pair-up the analyzer with your
preferred device for seamless connectivity and data
synchronization.
Start Measuring
- Select the desired measurement unit for your convenience.
- Follow the instructions for daily measurement to accurately
track your body fat composition and other related metrics.
Manage Your Health
This section provides information on data transmission, allowing
you to manage and analyze your health data effectively. Follow the
instructions to transmit your measurements for further analysis or
tracking.
Troubleshooting
The troubleshooting section offers solutions for common errors
or issues that may occur during measurement or data transmission.
Refer to this section if you encounter any problems and follow the
suggested steps to resolve them.
Specifications
The specifications section provides detailed technical
information about the Transtek Body Fat Analyzer GBF-2008-B1,
including its features, dimensions, and other relevant
specifications.
Maintenance
Refer to the maintenance section for instructions on how to
properly care for and maintain the Transtek Body Fat Analyzer
GBF-2008-B1. Following these guidelines will help ensure the
longevity and optimal performance of the product.
Warranty
The warranty section provides information about the warranty
coverage for the Transtek Body Fat Analyzer GBF-2008-B1. Read this
section to understand the terms and conditions of the warranty.
PROFESSIONAL MEDICAL PRODUCTS
ANALIZZATORE DI GRASSO CORPOREO BODY FAT ANALYZER ANALYSEUR DE GRAISSE CORPORELLE ANALIZADOR DE GRASA CORPORAL ANALISADOR DE GORDURA DIGITAL KÖRPERFETTWAAGE ANALIZATOR TKANKI TLUSZCZOWEJ –
GBF-2008-B1 (27086)
Fabbricante / Manufacturer / Fabricant / Fabricante Fabricante / Hersteller / Producent / : ZHONGSHAN TRANSTEK ELECTRONICS CO., LTD 23, Jin’an Road, Minzhong, Zhongshan, 528441, Guangdong, China Made in China
Importato da / Imported by / Importé par / Importado por / Importado por Importiert von / Importowane przez / : Gima S.p.A. Via Marconi, 1 – 20060 Gessate (MI) Italy [email protected] – [email protected] www.gimaitaly.com
IP21
M27086-M-Rev.0-12.21
ENGLISH
12
Thank you very much for selecting the Transtek Body Fat Analyzer GBF-2008-B1. Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product, and keep the manual well for further reference in case you have problems.
Table of Contents
SAFETY INFORMATION Safety and usage information…………………………………………………………………………………………….13 Tips ………………………………………………………………………………………………………………………………..14
OVERVIEW Device components ………………………………………………………………………………………………………….14 List …………………………………………………………………………………………………………………………………15 LED Display…………………………………………………………………………………………………………………….15
INITIAL START-UP General instructions………………………………………………………………………………………………………….15 Insert the batteries……………………………………………………………………………………………………………16 Install APP and Pair-Up …………………………………………………………………………………………………….16
START MEASURING Select Measurement Unit ………………………………………………………………………………………………….17 Daily Measurement…………………………………………………………………………………………………………..17
MANAGE YOUR HEALTH Data transmission…………………………………………………………………………………………………………….18
TROUBLESHOOTING Error prompt ……………………………………………………………………………………………………………………18 When measuring … ………………………………………………………………………………………………………….19 When data transmitting……………………………………………………………………………………………………..19
SPECIFICATIONS ……………………………………………………………………………………………………………20 MAINTENANCE ………………………………………………………………………………………………………………20 WARRANTY ……………………………………………………………………………………………………………………21
13
ENGLISH
SAFETY INFORMATION
Safety and Usage Information
The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury.
CAUTION Transtek’s Body Fat Analyzer GBF-2008-B1 offers you a seamless way to manage your health. Please be aware that this device is designed for healthy population over 10 years old self-measuring and self-monitoring body compositions. Any information provided by this device is in no way meant to treat, cure or prevent any disease or illness from happening. If in doubt, contact your physician. This device is contraindicated for any female subject who may be suspected of, or is pregnant. Otherwise, the effects of this device on the fetus are unknown. This device is contraindicated for any person who is connected to a wearable or implantable electronic device or instrument such as a pacemaker or defibrillator. This device should not be used for anyone who is acutely or chronically ill because of suffering from a disease or taking medications that affect your water levels. The accuracy of readings for these patients has not been verified. Specific medical advice should be obtained from a physician. GBF-2008-B1 is equipped with data transmission function. It may emit electromagnetic energy so as to perform its intended function. Nearby portable and mobile RF communications equipment can affect the performance of GBF-2008-B1. And the device can interfere vicinity electrical equipment. Manufacturer will make available on request circuit diagrams, component parts list,etc. WARNING: No modifications of this equipment is allowed. This may result in increased EMISSIONS or decreased IMMUNITY of GBF-2008-B1. Please use the device according to the user manual. Any misuse can cause electric shock,burns, fire and other unexpected hazards. Please use and storage the device under the environment which was provided in the user manual. Don’t expose the device to extreme temperatures, direct sunlight, moist or corrosive environment. Do not step on the scale when your body or feet are wet, especially after bathing or showering to prevent slipping. Please keep the device out of reach of infants, children or pets, since inhalation or swallowing of small parts is dangerous or even fatal. Please don’t use the device out of lifetime any more because degraded sensors and electrodes, or loosened electrodes can degrade performance or cause other problems. If you have an allergy to stainless steel, please avoid to contact to the electrodes of the device. The patient is an intended operator. The patient can measure, transmit data and charge battery under normal circumstances and maintain the device and its accessories according to the user manual.
INDICATIONS FOR USE · The Transtek Body Fat Analyzer measures weight and uses bio-electrical impedance analysis (BIA)
technology to estimate body fat in generally healthy children 10-17 years old and healthy adults. · It is intended for use in the domestic setting only.
ENGLISH
14
Tips
To ensure the accuracy of measurement, please follow below instructions when you start measurement. · Place the scale on a flat, hard surface. Soft surface such as carpet will affect the performance of the
scale. · Step onto the platform with bare feet. Stand still and keep full contact with the electrodes until the meas-
urement is complete. · Start measurement at least two hours after Getting up or Dinning. · Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and dining. · Always start measurement in the same time slot and on the same scale located on the same flat, hard
surface. · For maximum accuracy and repeatability , it is recommended that you should use the device in the
same time of the day and on the same location. · The condition of the skin on the bottom of your feet can affect the reading. The natural effects of aging
or activity can make this skin hard. Take the reading with clean, slightly damp feet for best accuracy. If you are having a problem on operating this scale please contact customer service. · Body fat percentage estimates will vary with the amount of water in the body, and can be affected by dehydration or over-hydration due to such factors as alcohol consumption, menstruation, illness, intense exercise, etc.
OVERVIEW
Device Components
LED Display
Electrodes
Electrode
UNIT Button Battery Compartment
Sensor
15
List
1. Body Fat Analyzer GBF-2008-B1 2. Four AAA-size Batteries (1.5V per each) 3. User Manual
LED Display
ENGLISH
lb Pound kg Kilogram
Bluetooth Connection Indication
INITIAL START-UP
General Instructions
Transtek Body Fat Analyzer GBF-2008-B1 applies BIA (Bio-impedance Analysis) technology. A small amount of weak current flows through the human body so as to detect the bio-impedance and estimate body fat. The electrical current is small and may not be felt. This BIA technology is cheap, safe, non-invasive, toxic-free and harmless. It also possesses the characteristics of simple operation and abundant information. The current mentioned above is less than 0.5mA. However, please be aware that anyone with an wearable or implantable medical electronic instrument, such as a pacemaker, must avoid using this device. The intended use of this device is for healthy children 10-17 years old and healthy adults.
ENGLISH
16
Insert the Batteries
· Open the battery door in the back of the scale.
· Insert the batteries (4 x 1.5V AAA) into the battery compartment according to the polarity indications marked inside the compartment. * The digits ” 8888 ” will be shown on the LED.
· Close the battery door and wait until the digits “00.00” are shown on the LED
CAUTION · When the symbol “Lo” appears, the device will power off in about 4s. Then you shall replace with
a new set of batteries. Please replace all four batteries at the same time. Do NOT mix the old batteries with the new one. · Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. · Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries and scrapped device. · If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries before storing. · Do not mix alkaline, standard (carbon-zinc), or rechargeable (Ni-Cd, Ni-MH, etc) batteries.
Install APP and Pair-Up
With the advanced Bluetooth 5.0 technology applied, the mobile or portable equipments, which are equipped with Bluetooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG, are capable to receive your personal health data. Just simply install the Tuya Smart App and pair up your scale with your mobile or portable equipments. Then you may enjoy the comprehensive health solution provided by Tuya. Note: It is only available for the device which supports Bluetooth 5.0 technology.
· For the first time, the scale will automatically enter bluetooth pairing mode. · Turn on bluetooth and the Tuya Smart App. Make sure both are ON when pair-up is proceeding.
If SUCCEED, symbol ” ” will be shown on the LED.
17 If FAIL, symbol ” ” will not be shown on the LED.
ENGLISH
If symbol ” ” blinks, it means the device is being searched.
START MEASURING
Select Measurement Unit
With batteries correctly installed, press “UNIT” button in the back of the scale to select measurement unit. The default measurement unit is “kg”. You may press “UNIT” button to choose between kilogram and pound.
Daily Measurement
· With original SENSE ON patent technology, GBF-2008-B1 will switch on as you step on the platform barefooted.
· Stand still and keep full contact with the electrodes until the LED stops blinking digits.
ENGLISH
18
MANAGE YOUR HEALTH
Data Transmission
· With GBF-2008-B1 successfully pair-up with your smartphone, the measurement data will be transmitted to your mobile via Bluetooth.
· ONLY when the measuring results are attached to a specific User ID will it be transmitted to your mobile after measurement.
· The symbol will display after successful data transmission, and you may check your personal health data stored in your smartphone.
· If the data transmission fails, the symbol doesn’t display. The pending measurement data will be temporarily kept in the scale and transmitted to your smartphone when next measurement is complete.
CAUTION · Interference may occur in the vicinity of equipment marked with the following symbol .
And the Analyzer may interfere vicinity electrical equipment. · To enable the data transmission function, this product should be paired to a Bluetooth 5.0 or
above end.
How to mitigate possible interference? 1. The range between the Analyzer and the Bluetooth end should be reasonably close, from 1 meter
to 10 meters. Please ensure no obstacles between the Analyzer and the Bluetooth end so as to obtain quality connection. 2. To avoid interference, other electronic devices (particularly those with Bluetooth transmission / Transmitter) should be kept at least 1 meter away from the Analyzer.
TROUBLESHOOTING
Error Prompt
Error
Description Overload.
Low Battery.
Solution Stop using this scale for measurement.
Replace all four batteries in the same time. Please purchase the authorized batteries for replacement.
19
ENGLISH
When Measuring…
Problem
Root Cause
Solution
Abnormal measuring results: – Too high; – Too low; – Huge difference between two recent measurement.
Incorrect posture
The device is located on the soft ground such as a carpet or on a rugged surface.
Your feet are too dry.
Please step on the platform barefooted and stand still.
Please place the device on a flat, hard surface.
Wipe your feet with a damp cloth, keeping them slightly damp when starting measurement.
No display on LED when the device powers on.
Batteries not yet installed. Worn batteries.
Install the batteries. (Please refer to Insert the Batteries)
Replace all four batteries at the same time. Please purchase the authorized batteries for replacement.
CANNOT proceed to analyze body fat.
Step onto the platform wearing socks or shoes.
The system cannot identify the possible User ID with most similar data.
Please keep barefooted during the measurement, and keep full contact with the electrodes as well.
Please assign a User ID again on the APP.
The device powers off.
Low battery.
Replace all four batteries at the same time. Please purchase the authorized batteries for replacement.
When Data Transmitting…
Problem Data transmission failed.
Root Cause Bluetooth is OFF. The APP is OFF. Out of range of Bluetooth transmission. None of the user ID is assigned.
Solution Turn ON the Bluetooth via Settings. Press the icon to turn ON your APP. Place your smartphone closer to the scale. Please assign a User ID on the APP.
ENGLISH
20
SPECIFICATIONS
Product Name Dimension Net Weight Display Measurement Unit Measurement Range Division Accuracy
Working Environment
Storage Environment
Power Source Auto-ON Auto-OFF Accessories
Mode of Operation
Body Fat Analyzer (GBF-2008-B1)
Scale: 300x300x25.5mm (Approximately)
Approximately 1.72kg ( Including the dry cells)
Digital LED
Pound / Kilogram
11lb to 397lb / 5kg to 180kg
5-100kg: 0.05kg / 0.1lb; 100-180kg: 0.1kg / 0.2lb
5-50: ±0.2kg;
50.05-100: ±0.3kg;
100.1-150: ±0.4kg; 150.1-180: ±0.5kg
Temperature: 5 to 40 Relative Humidity: 90% RH Atmospheric pressure: 86kPa to 106kPa
Temperature: -20 to 60 Relative Humidity: 90% RH Atmospheric pressure: 50kPa to 106kPa
6V (Four AAA-size Batteries)
SENSE ON technology
The scale will turn off after about 30s if there is no operation.
1. Four AAA Size Batteries 2. User Manual
Continuous Operation
About the Accuracy of This Product · This product passes strict inspection before delivery and therefore its accuracy is guaranteed by the
manufacturer. Please refer to the above table for the descriptions on accuracy. · This product is specially designed for body fat analysis as well as weight measurement. It should NOT be used by anyone during the process of transaction for verification of goods’ weight.
MAINTENANCE
When carrying out usual maintenance, please ensure practice of the following Do’s and Don’ts: · DO use a dry soft cloth to wipe the dust. · DO use a wet soft cloth, dipped into water and wrung out, to wipe the dirt. Then use a dry soft cloth to
dry up the device. · DON’T wash the device with water or immerse it in water. · DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of discolor or malfunc-
tion. · DON’T disassemble this device. If you have any problems, please contact Transtek.
(Please refer to Warranty for contact information)
21
Product code Direct current
Keep in a cool, dry place Product complies with European Directive Caution: read instructions (warnings) carefully Follow instructions for use Serial number
ENGLISH
Lot number Date of manufacture Keep away from sunlight Covering Protection rate Type BF applied part WEEE disposal
Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment.