Prem-i-air Eh1927 Air Conditioner Casement Window Seal Kit User Manual

EH1927 Air Conditioner Casement Window Seal Kit

EH1927 Air Conditioner Casement Window Seal Kit Manual

Product Information:

  • The EH1927 Air Conditioner Casement Window Seal Kit is designed
    to work with casement windows only with a perimeter of up to
    4m.
  • The kit contains 1 x 8m reel of hook and loop tape and 1 x 4m
    material seal fitted with hook and loop tape.
  • The product is fitted with hook and loop tape that allows the
    product to be quickly installed and removed from the window.
  • The kit comes with two zips which can be adjusted to produce a
    suitable aperture for the exhaust hose of your air conditioner to
    fit through.
  • The product is guaranteed from defects for a period of 12
    months however damage caused by wind or user misuse is not
    covered.

Product Usage Instructions:

  1. Check the kit contains all items mentioned in the manual.
  2. Measure both the dimensions of your window frame and the
    casement window as per the diagram.
  3. Cut the hook and loop tape into 8 sections matching the
    measurements you have taken from the window and window frame. 2 x
    size A, 2 x size B, 2 x size C, 2 x size D.
  4. In turn remove the backing from the tape and fix the strips to
    the corresponding place on the window as indicated in the
    diagram.
  5. Lay the material section flat onto a tabletop.
  6. Find the middle point of the straight side of the material and
    fix this on to the tape attached to the casement window close to
    the handle of the window by pressing the hook and loop tapes
    together. Work out from this point on both sides fixing the
    material in place.
  7. Find the mid-point of the material section on the curved side
    and begin to fix this to the tape on the window frame starting at a
    point close to the handle. Work out on both sides fixing the
    material in place as you go.
  8. Any spare material should be rolled up and tied in place.
  9. Slowly open the window until the material is taught between the
    frame and the window.
  10. The material section is fitted with two zips which can be
    adjusted to produce a suitable aperture for the exhaust hose of
    your air conditioned to fit through. After adjusting these zips
    feed the exhaust hose through the aperture making sure that the
    exhaust hose is at least 5 inches through this gap. Close the zips
    to clamp the hose in place. If the zips are moving out of position
    fix a cable tie (not supplied) through each of the zip puller tags
    and tighten until the hose is fixed in place.
  11. The material section can be removed and reinstalled onto the
    hook and loop as required.

EH1927 Air Conditioner Casement Window Seal Kit Manual
IMPORTANT
Installers and Users Please Note:
These instructions should be read careful and left with the product for future reference.
BEFORE USE
Check your kit contains the following items.
1 x 8m reel of hook and loop tape and 1 x 4m material seal fitted with hook and loop tape
Important Safety Information and Advice
1) This kit is designed to work with casement windows only with a perimeter of up to 4m. 2) Do not use this product in strong or gusty winds. Windows should be secured and locked in
place. 3) Do not allow children and pets to play in the vicinity of this product. Fall risk. 4) Windows are not secure when using this product. Close windows and lock in place when not
in the room Security/fall risk.
How to Install This Product.
The product is fitted with hook and loop tape that allows the product to be quickly installed and removed from the window. Follow these simple instructions below to understand how to install this product.
1) Measure both the dimensions of your window frame and the casement window as per the diagram.
2) Using these measurements cut the hook and loop tape into 8 sections matching the measurements you have taken from the window and window frame. 2 x size A, 2 x size B, 2 x size C, 2 x size D.
3) In turn remove the backing from the tape and fix the strips to the corresponding place on the window as indicated in the diagram
4) Lay the material section flat onto a tabletop. 5) Find the middle point of the straight side of the material and fix this on to the tape attached
to the casement window close to the handle of the window by pressing the hook and loop tapes together. Work out from this point on both sides fixing the material in place.

6) Find the mid-point of the material section on the curved side and begin to fix this to the tape on the window frame starting at a point close to the handle. Work out on both sides fixing the material in place as you go.
7) Any spare material should be rolled up and tied in place. 8) Slowly open the window until the material is taught between the frame and the window. 9) The material section is fitted with two zips which can be adjusted to produce a suitable
aperture for the exhaust hose of your air conditioned to fit through. After adjusting these zips feed the exhaust hose through the aperture making sure that the exhaust hose is at least 5 inches through this gap. Close the zips to clamp the hose in place. If the zips are moving out of position fix a cable tie (not supplied) through each of the zip puller tags and tighten until the hose is fixed in place. 10) The material section can be removed and reinstalled onto the hook and loop as required.
This product is guaranteed from defects for a period of 12 months however damage caused by wind or user misuse is not covered.
Prem-i-air Appliances Ltd Lancots Lane Sutton Oak St. Helens WA9 3EX 01744 745 000
[email protected] www.prem-i-air.co.uk

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals