C601-i Digital Thermometer
User Manual: Digital Thermometer
Specifications
- Temperature Measure Range:
- Power Supply: 1.5V (AG13) X 1
- Max and Min temperature memory function
- LED alarm Indicator light
Operation Instructions
- Open back cover and Install battery
- Button Function:
- [MAX/MIN]: Display the recorded highest and lowest temperature
value and long press to clear recorded values - [IN/OUT]: Change indoor and outdoor (in/out of freezer)
temperature display - [AL] : Setup outdoor temperature alarm range; turn on (off)
temperature alarm mode - [ADJ]: Adjust the setting projest value, temperature alarm mode
ON, if not, temperature alarm mode will be OFF.
- [MAX/MIN]: Display the recorded highest and lowest temperature
Note:
- As a multi-function thermometer, if used as a freezer
thermometer, you need put the sensor in the freezer/fridge, then
the ‘OUT’ reading is freezer temperature. - While testing outdoor temperature or freezer temperature, show
LL.L, please wait for 10s, if problem continue, please take out the
probe and reinsert. If show HH.H, please take out the probe and
reinsert. - If in the MIN condition, it display LLL, please press [MIN/MAX] for 2s to clear the data.
Notice:
- Please take out battery about 2s, and reinstall if the device
doesn’t work. - Please put battery on appointed place of government after using
up. - Don’t inform if any change on technology.
Product Information
The Digital Thermometer is a multi-function thermometer that can
measure temperature in both indoor and outdoor settings. It comes
with a temperature range display and a power supply of 1.5V (AG13)
X 1. The thermometer also features a Max and Min temperature memory
function and a LED alarm indicator light. The device is easy to
operate with its four button functions – MAX/MIN, IN/OUT, AL, and
ADJ. It is important to note that if used as a freezer thermometer,
the sensor needs to be placed in the freezer/fridge, and the ‘OUT’
reading will indicate the freezer temperature.
Product Usage Instructions
- To start using the Digital Thermometer, open the back cover and
install the battery. - Use the MAX/MIN button to display the highest and lowest
recorded temperature values. Long press this button to clear the
recorded values. - The IN/OUT button can be used to switch between indoor and
outdoor temperature displays. - The AL button is used to set up the outdoor temperature alarm
range. Turn on/off the temperature alarm mode using this
button. - The ADJ button is used to adjust the setting project value.
Ensure that the temperature alarm mode is ON; otherwise, it will be
OFF. - If testing outdoor or freezer temperature, wait for 10 seconds
if the display shows LL.L. If the problem persists, take out the
probe and reinsert it. If the display shows HH.H, take out the
probe and reinsert it. - If the thermometer is in the MIN condition and displays LLL,
press the MIN/MAX button for 2 seconds to clear the data. - After use, take out the battery for about 2 seconds and
reinstall it if the device doesn’t work. Dispose of the battery in
the appointed place of government after using it.
User Manual
Digital Thermometer
1. Specifications______________________
__
1-1. Temperature Measure Range:
Indoor: -10°C ~ 50°C ( 14°F ~ 122°F)
Outdoor/Fridge: -50°C ~ 70°C (-58 °F ~ 158°F)
1-2. Power Supply: 1.5V (AG13) X 1
2. Function Brief Introduction__________ 2-1. Indoor / outdoor temperature 2-2. Outdoor high and low temperature alarm 2-3. °C/°F temperature switching display
____
2-4. Max and Min temperature memory function
2-5. Frost Point Alarm: -1°C ~ 4°C(30.2°F ~ 39.2°F)
2-6. LED alarm Indicator light
3. Operation Instructions___
___________
3-1. Open back cover and Install battery
3-2. Button Function
[MAX/MIN]: Display the recorded highest and lowesttemperature value and long press to clear recorded values
[IN/OUT]: Change indoor and outdoor (in/out of freezer)temperature display
[AL] : Setup outdoor temperature alarm range; turn on (off)temperature alarm mode
[°C/°F]: Switch temperature unit between °C and °F [ADJ]: Adjust the setting projest value3-1. Press [IN/OUT], display current Indoor temperature when screen shows “IN”. Press [MAX/MIN], display recorded indoor highest or lowest temperature value: Press [MAX/MIN] and hold over 2s to clear recorded highest and lowest temperature value. 3-2. Press [IN/OUT], display current outdoor temperature when screen shows “OUT”. Press [MAX/MIN], display recorded outdoor highest or lowest temperature value. Press [MAX/MIN] and hold over 2s to clear recorded highest and lowest temperature value. 3-3. Just press [AL] turn on/off temperature alarm mode, show
, temperature alarm mode ON, if not, temperature alarm mode will be OFF.
3-4. Under temperature alarm mode, if you don’t do any Hi/Lo set, the default setting is frost point range -1°C ~ 4°C (30.2°F ~ 39.2°F) alarm, means when you put the cable sensor in the freezer, the thermometer will alarm if the temperature within this range. 3-5. The thermometer can be used as both ambient alarm temperature and freezer thermometer. If as freezer thermometer, put the sensor in freezer “OUT” refer to the freezer temperature, and if used as ambient thermometer please put probe outside of the window, but thermometer must be put indoor for non-waterproof.
4. How to set alarm 4-1. High and low temperature alarm setup: Under temperature alarm mode, long press [AL] button 2s enter into high and low temperature alarm setup state, and when value flash, press [ADJ] to adjust value (long press to fast adjust), then press [AL] to confirm setup. So, it will occur 2 situations: 1. When the 1st setup temperature LOWER than the 2nd setup temperature, the current alarm range is between the 1st setup temperature and the 2nd setup temperature. e.g. press [AL] hold 2s, then value flash, press [ADJ] to setup temperature value 5°C, press [AL] again to confirm value 5°C, then setup 2nd temperature, such as 17°C, then the thermometer will alarm if current temperature range is 5°C ~ 17°C.
2. When the 1st setup temperature HIGHER than the 2nd setup temperature, the current alarm range is over 1st setup temperature or below 2nd setup temperature. e.g. press [AL] hold 2s, then value flash, press [ADJ] setup temperature value 7°C, press [AL] again to confirm value 7°C, then setup the 2nd temperature, such as -5°C, the thermometer will alarm if current temperature over 7°C or below -5°C.
NOTE: 1. As a multi-function thermometer, if used as a freezer thermometer, you need put the sensor in the freezer/fridge, then the ‘OUT’ reading is freezer temperature. 2. While testing outdoor temperature or freezer temperature, show LL.L, please wait for 10s, if problem continue, please take out the probe and reinsert. If show HH.H, please take out the probe and reinsert.
3. If in the MIN condition, it display LLL, please press [MIN/MAX] for 2s to clear the data.
NOTICE: 1. Please take out battery about 2s, and reinstall if the device doesn’t work. 2. Please put battery on appointed place of government after using up. 3. Don’t inform if any change on technology.