A305S Scent Diffuser Machine
Product Information
Product Name: A305S/M/L
Model Number: 50301-00001B1.0CYG-00117-B10-A305
Product Manual: SCENT MARKETING
Product Usage Instructions
- To download the APP, please search “scent marketing” in Google
Play or App Store. - To add a device, follow these steps:
- Enter the password.
- Set the device name and location.
- To delete a working period, use the time switch function.
- To set the time and date, use the time setting function.
- To turn on/off the fan, press and hold the corresponding button
for 3 seconds. - The button will be locked automatically if there is no further
manual manipulation within 60 seconds. Press the SET button for
about 5 seconds to unlock. - To adjust the concentration grade, use the touch buttons to
increase or decrease the grade. - To amend the password, press the reset button to restore the
factory settings (password: 8888). - To set the working time period, follow these steps:
- Select the working period (1-5).
- Choose ON or OFF for the selected period.
- Adjust the operation time and grade.
- Repeat the steps for other days.
- Confirm and exit the settings.
- Note: Customized grade settings can only be done through the
APP. - Ensure that the start working period is not the same as the
stop working time to avoid machine malfunction.
50301-00001B1.0CYG-00117-B10-A305
APP instructions
Where can I download this APP: Please search “scent marketing” in Google play or App store.
Add device
AAA
AAA
AAA
Input password
Name: AAA
Label: AAAAAA
Amend device name Remarks: location
Delete working period
Add working period Time switch
(PS: There are 5 working periods available to be set.)
Time setting
Date
Mon
TUES WED THUR FRI SAT SUN
ON/OFF
Local time Diffusing display
Current grade
Power on/off Connect power supply, power on with a sound “beep”, and the screen displays initial time and current grade. The screen will be off when disconnect the power.
Fan on/off Touch button (3s) to turn on fan, touch button (3s) to turn off fan.
Mon
Auto-lock and un-lock
TUES
WED
Button will be locked automatically if there is no any
THUR
FRI
further manual manipulation in 60s; Touch SET
SAT
(about 5s) comes out with sound “beep” and screen
SUN
lights on to unlock machine.
Local time setting Touch SET button (about 3s) till a sound “beep” comes out for day setting; touchorto adjust the day; touch ENT button for local time setting, touch orto adjust the time (Figure 1)
(1)
Mon TUES WED THUR FRI SAT SUN
Concentration grade setting
There are 20 grades available. Touchto increase
(2)
grade, touch to decrease grade(Figure 2).
Amend password
AAAA AAAA AAAA
If you forget the password, please press the reset button to restore the factory settings. The factory settings password is 8888.
Slide up and down to adjust
Select the day
Select grade
Work time period setting
There are 5 working periods available to be set every day Mon
(Figure 3).
TUES WED
Touch SET button to set working period (ON1) , touch
THUR FRI
or to choose working period (1-5); touch ENT button SAT
for the working period switch, touch or to choose ON SUN
or OFF, touch ENT button again to move to the operation
time, touch orto adjust number.
Touch ENT again for grade. Next touch ENT to choose the
(3)
day (MON), touch button to turn on the working period
(ON1) (Figure4), touch button to turn off the working
Mon
period (OFF1) (Figure5).
TUES WED
Touch ENT to move to the next day and repeat the steps
THUR FRI
for TUES to SUN.
SAT
Once finish, touch SET to confirm and exit, Repeat the
SUN
same setting steps of ON1 for ON2, ON3 ON4 and ON5.
PS:Grade display with “-Cu-” is for customized grade set
by APP only(Figure6).
(4)
Machine doesn’t work when the start working period is as
same as stop working time
Mon
TUES
Working time period
00:00 –
00:00
00:00 –
00:00
00:00 –
00:00
00:00 –
00:00
00:00 –
00:00
WED THUR FRI SAT
SUN
Mon
ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF
Thues
ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF
Wed
ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF
(5)
Thur Fri Sat
Sun
ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF ON/OFF
Mon
TUES WED THUR FRI SAT SUN
(PS: The first working period is factory defaults with
start working time 07:00 and stop working time 19:00,
Grade1, the rest are all with 00:00.)
(6)
PRODUCT MANUAL
SCENT MARKETING
A305S/M/L
Concentration and Consumption
Grade
Consumption(ml/h) work(s) intervals(s)
A305S-BLE A305M-BLE A305L-BLE
G1
15s
300s
0.10
0.1
0.2
G2
15s
150s
0.14
0.2
0.3
G3
20s
120s
0.18
0.3
0.5
G4
20s
85s
0.22
0.4
0.6
G5
25s
80s
0.26
0.5
0.8
G6
30s
75s
0.30
0.6
0.9
G7
30s
60s
0.34
0.7
1.0
G8
30s
50s
0.38
0.8
1.2
G9
30s
40s
0.45
0.9
1.3
G10
30s
33s
0.50
1.0
1.5
G11
33s
30s
0.55
1.1
1.8
G12
40s
30s
0.60
1.2
2.0
G13
50s
30s
0.65
1.3
2.3
G14
60s
30s
0.70
1.4
2.5
G15
75s
30s
0.75
1.5
2.8
G16
80s
25s
0.80
1.6
3.0
G17
85s
20s
0.85
1.7
3.3
G18
120s
20s
0.90
1.8
3.5
G19
150s
15s
0.95
1.9
3.8
G20
300s
15s
1.00
2.0
4.0
Cu
5-500s
5-500s
Up grade
Down grade
Notice:1. Above date is base on test trial. 2.Consumption data is for reference only. Different fragrance may be coming with different consumption.
12
Specification
Product Name Model
Coverage Dimension
Bottle Weight Power Voltage
: Aroma diffuser : A305S/ A305M/ A305L : 200m2/600m3 400m2/1200m3 : 295*222*112.5mm : 850ml : 2.05kg 2.45kg 2.60kg : 6W /6W / 9W : DC12V
800m2/2400m3
Overview
Atomized connector
Lock
Control Atomized
Mounting Mounting
panel
head Bottle
nail
bracket
DC connector
Instruction
Plug
Bottle Bottle cap PU tube
Manual
Atomized nozzle Key connector
Mounting bracket Sealing tape
Screw
Usage of sealing tape: 1.Before replacing atomizing core, wrap sealing tape around atomized core thread about 3-5 turns to avoid air leakage; 2.Before connecting atomized connector, wrap sealing tape around atomized connector thread about 3-5 turns to avoid air leakage.
1.Open the door by key 2.Unscrew the atomized nozzle, take out the bottle 3.Twist the bottle and fill essential oil 4.Put atomized head to bottle and screw the atomized nozzle 5.Finish time setting and lock machine
! Caution
Shall not modify, disassemble or repair the machine arbitrarily. Any failure happens, please contact technician in time. Shall not damage the power cord, force to bend, yank, heavy load, clip or reprocess. – Shall not use damaged plug or unmatched with the socket; – Shall not wet the machine or the plug; – Shall not use overloaded power socket, wire or broken plug. Shall not touch the wire or product shell when thundering or/and lightening. Shall not disassemble the machine when it is under operating.
Warning
1.Please keep the machine vertical. Tilt or lie flatly may cause oil over flow. Themachine efficiency may be affected.
2.Shall not modify, disassemble or repair the machine if you are not a technician. If any failure happens to the machine, please contact our technical personnel.
3.The machine is stop during off work time period, even the Atomization display is on
4.The button is invalid and no display on screen when machine locked
5.If the display is cluttered, freezes or other problem, please restart machine to reset to defaults(Method: Press ENT button and hold on about 5 seconds till hear a sound “beep”)
Installation
The method of using expansion bolts
Drill the wall, insert the expansion tube into the hole, put the screw into the expansion tube and tighten it
Installation steps
Direction
Idea for Hotels, Conference rooms, Malls, Exhibition halls, Major retailers, Bars, SPAs, Business places or anywhere you wanto a fragrance experience.
Troubleshooting
Before asking to have the machine repaired, please try to diagnose the problem first following to below instructions.
Breakdown
Solution
Does not diffuse
-Check whether the mode you choose is correct or not. -Check if the machine is during “Non-Working period” -Air pump may be damaged, change a new one. -Check whether the tube is loose or not
Weak diffuse Oil leaking Oil sprinkle
Abnormal noise
-The atomizing core is blocked, clean by alcohol or change a new component.
-Check whether the gasket is damange/loose or not. -Check whether the tube is loose or not
-Check whether the bottle is loose or not -The gasket in the atomized head is damaged or
-The atomized head is damaged, change a new one -The machine is tilled or lie down, keep the machine
-The air pump is loose, retighten the pump -The air pump is damaged, change a new one.
1.Aim at the position of the mounting bracket, then drill the hole in the wall and insert the expansion bolts into the hole in the wall; 2.Install the mounting bracket on the wall with screws, and finally hang the machine on the mounting bracket.
22
297*210mm 128g
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement.
33
CE Caution
Use the product in the environment with the temperature between -10 and 50; Otherwise, it may damage your phone. I t can be operated under 2000m. For the following equipment: Product Name: Aroma diffuser Model: A305 Guangzhou Chiyang Scent Technology Co., LTD. hereby declares that this [ Name: Aroma diffuser, Model: A305] is in compliance with the essential requirements and other relevant provisions of Directive 2014/ 53/ EU.
This product can be used across EU member states. CAUTI ON: RI SK OF EXPLOSI ON I F BATTERY I S REPLACED BY AN I NCORRECT TYPE. DI SPOSE OF USED BATTERI ES ACCORDI NG TO THE I NSTRUCTI ONS. Do not use other unauthorized chargers power supply for charging.
Do not use the product in environment below -10 or above 50 for charging.
Bluetooth Support Standard: Frequency Range: Max. RF Output Power: Type of Modulation: Data Rate: Quantity of Channels
802.15.1 2402-2480MHz 1.87dBm (EIRP) GFSK 1Mbps 40