Panbio HIV Self Test
Product Information – PanbioTM HIV Self Test
Product Description
The PanbioTM HIV Self Test is a diagnostic kit designed for
individuals to test themselves for the presence of HIV antibodies
in their blood. The kit provides a convenient and reliable way to
determine HIV status in the comfort of your own home.
Product Usage Instructions
- STEP 1: PREPARE
- Watch the instructional video provided.
- Precautions:
- Do not eat or drink while performing the test.
- Read all the steps before testing to ensure accurate
results.
- STEP 2: COLLECT BLOOD
- Prepare a timer and tissue (not included in the kit, but
needed). - Open and place all materials on a flat and clean surface:
- A Test device
- B 2 alcohol pads
- C Plaster
- D Buffer
- G Disposal bag
- Wash hands in warm water and dry. If warm water is not
available, rub hands together. - Choose the ring finger or middle finger.
- Massage and rub hand and finger to increase circulation.
- Clean the finger with an alcohol pad (B) and let it dry for 10
seconds. - Remove the lancet cover and press the lancet (F) against the
finger until it clicks. - Massage from the base to the tip of the finger and let 2 drops
of blood fall into the basin (1). If you are having difficulty,
wipe the finger clean and squeeze again. - Wipe the finger with an alcohol pad (B) and apply the plaster
(C). If needed, press on the plaster to stop bleeding. Start the
next step immediately to transfer the blood.
- Prepare a timer and tissue (not included in the kit, but
- STEP 3: TEST
- Squeeze the top of the specimen dropper (E).
- Dip the dropper into the blood in the basin and release slowly
to draw the blood into the dropper. - Place the dropper over the well and squeeze the top of the
dropper to apply 1 drop of blood into the well (2). - Hold the buffer bottle (D) vertically and apply 1 drop of
buffer into the well (3). Do not tilt. - Wait for 15 minutes.
- STEP 4: READ RESULT
Read the result in a well-lit area.
- A line appears only in the control region (C) area. There is no
line in the test region (T) area. The test did not detect the
presence of HIV; however, very recent exposure cannot be excluded.
It is recommended to conduct a retest after 6 weeks from the latest
risk of exposure to HIV. - One line in the control region (C) area, together with one line
in the test region (T) area, no matter how faint, indicates the
potential to be HIV positive. Consult a healthcare provider. A
reactive result must be confirmed by a lab test. Protect yourself
and others. Avoid any activity that could transmit HIV to
others.
STEP 1: PREPARE
PanbioTM
HIV Self Test
Catalog Number: 29012M001 EN
FPO
Watch the instructional video here.
Precautions
Do not use: · If you have a bleeding disorder.
· If you are on HIV treatment (ARVs).
· If you are needle-phobic.
· If the kit box or components are broken.
· If the kit or components have been used.
Do not eat or drink while you perform the test.
Before testing, you must read all the steps. Conformance with the test procedure is necessary to ensure an accurate result.
STEP 2: COLLECT BLOOD
1 PREPARE a timer and tissue.
Not included in the kit, but needed
2 OPEN AND PLACE all materials on a flat and clean surface.
A Test device
B 2 alcohol pads
C Plaster
D Buffer
G Disposal bag
3 WASH hands in warm water and dry. If no warm water is available, rub your hands together.
4 CHOOSE ring finger or middle finger.
or
PanbioTM HIV Self Test
4 15-20 min
C T
2
3
PanbioTM HIV Self Test
4 15-20 min
C Result
T
2
3
Well
E Specimen dropper
F Lancet
1
Basin
1
It only pricks once
Avoid dominant hand
5 MASSAGE and rub your hand and finger to increase circulation.
6 CLEAN your finger with an (B) alcohol pad. Let it DRY for 10 seconds.
7 REMOVE the lancet cover.
Needle inside
8 PRESS the (F) lancet against the finger until it clicks.
It only pricks once
“CLICK”
Press hard
9 MASSAGE from the base to the tip, and let 2 DROPS of blood fall into the basin (1). If you are having difficulty, wipe the finger clean and squeeze again.
10 WIPE the finger with an (B) alcohol pad, and APPLY the (C) plaster. If needed, press on the plaster to stop bleeding. Start the next step immediately to transfer the blood.
Wipe finger
Apply plaster
1
10
seconds
C T
3
2 drops
4 15-20 min
HIV Self Test
PanbioTM
1
2
Symbols and Explanations
= Sterilized using irradiation
= Caution
See the flip side for Steps 3, 4 and 5.
C T
3
STEP 3: TEST
11
SQUEEZE the top of the (E) specimen dropper.
Squeeze
DIP the dropper into the blood in the basin, and RELEASE slowly to draw the blood into the dropper.
Release
PLACE the dropper over the well. SQUEEZE the top of the dropper to apply 1 DROP of blood into the well (2).
Squeeze
1 drop
Slow
Slow
12 HOLD the (D) buffer bottle vertically, and apply 1 DROP of buffer into the well (3). Do not tilt
1 drop
13 START the timer. READ the result in 1520 minutes (4). Do not read past 20 minutes.
0 15 minutes
Wait
15 minutes
Read
20 minutes
3
C T
3
C T
3
C T
PanbioTM HIV Self Test 4 15-20 min
PanbioTM HIV Self Test 4 15-20 min
PanbioTM HIV Self Test 4 15-20 min
PanbioTM HIV Self Test 4 15-20 min
1
2
1
2
1
2
1
2
STEP 4: READ RESULT
14 READ the test result in 1520 minutes.
Read the result in a well-lit area Control line
Test line
PanbioTM
HIV Self Test
4 15-20 min
C T
2
3
NONREACTIVE (Negative)
PanbioTM
HIV Self Test
4 15-20 min
C T
2
3
REACTIVE (Positive)
PanbioTM
HIV Self Test
4 15-20 min
C T
2
3
PanbioTM
HIV Self Test
4 15-20 min
C T
2
3
Place your test device here
1
A line appears only in the control region (C) area. There is no line in the test region (T) area. The test did not detect the presence of HIV; however, very recent exposure cannot be excluded.
It is recommended to conduct a retest after 6 weeks from the latest risk of exposure to HIV.
One line in the control region (C) area, together with one line in the test region (T) area, no matter how faint, indicates the potential to be HIV positive.
Consult a healthcare provider. A reactive result must be confirmed by a lab test. Protect yourself and others. Avoid any activity that could transmit HIV to others.
Product not available in all countries. For more information, please contact your local Abbott representative. © 2023 Abbott. All rights reserved. All trademarks referenced are trademarks of either the Abbott group of companies or their respective owners. COL-19429-01 03/23
TEST DID NOT WORK (Invalid)
PanbioTM
HIV Self Test
4 15-20 min
C T
2
3
PanbioTM
HIV Self Test
4 15-20 min
C T
2
3
If no line appears in the control region (C) area, even if a line appears in the test region (T) area, the test did not work.
Test again using a new kit, or consult a healthcare provider.
STEP 5: DISPOSE
15 PLACE all used components into the (G) disposal bag.
HPIVanSbelifoTMTest 4 15-20 min
C T 3
2
1
16 SEAL the (G) disposal bag tightly. “CLICK”
17 THROW AWAY the (G) disposal bag in the waste bin.
Blood can transmit infectious diseases. Clean up spills
Dispose in accordance with local regulations.