Saxby Lighting 99566 Nimbus Cct 12w Led Light Instruction Manual

99566 Nimbus CCT 12W LED Light

Product Information

  • Wiring: The product features a quick fit connection case
    that allows for easy wiring. No tools are necessary for
    installation.
  • Technical Data:
    • Supply Voltage: 220-240 V~, 50 Hz
    • Bulb: 99566 – 12W LED module (SMD) CCT, 3000K / 4000K /
      6000K; 99767 – 24W LED module (SMD) CCT, 3000K / 4000K / 6000K
    • Energy Efficiency: Class D
    • Light Source: Non-replaceable
    • Control Gear: Non-replaceable
    • Conformity: Conforms to all relevant UKCA Directive and
      EC Directive requirements
    • Class: Class 1 (must be connected to earth)
    • IP Rating: IP44
    • IK Rating: IK08
    • Suitable for Dimming: No
  • Care and Safety:
    • We recommend cleaning the product with a soft dry cloth. Do not
      use solvents or abrasive cleaners as they may damage the
      finish.
    • The shade can be removed and washed in warm water or cleaned
      with a damp cloth.
    • Always switch off the power supply before cleaning for
      safety.
    • If the shade becomes cracked or damaged, it must be replaced
      immediately. The fitting should not be used without the shade in
      place.
  • Disposal: Waste electrical products should not be
    disposed of with household waste. Please recycle where facilities
    exist. Check with your Local Authority or local store for recycling
    advice.

Product Usage Instructions

  1. Ensure that the existing light fitting is completely removed
    before installing the new product. Take note of the position of
    each set of wires.
  2. Isolate/switch off the power at the fuse board before
    proceeding with the installation.
  3. Seal the screws and cable entry points to maintain the IP
    rating of the product.
  4. Fix the plastic plugs supplied into the ceiling, ensuring that
    the ceiling is capable of holding the weight of the product. Avoid
    damaging any concealed wiring and pipes.
  5. Plug the cables directly into the wire fast connection block
    inside the quick fit connection case:
  • Live: Brown (or Red)
  • GND: Yellow Green
  • Neutral: Blue (or Black)
  • The wire stripping length should be between 11-13mm.
  • Three color rings are supplied: Red, Blue, and Yellow.
  • Choose your preferred color (WW – 3000K, CW – 4000K, DW –
    6000K) before installing by using the CCT switch on the back of the
    lamp body.
  • Wiring

    Having correctly identified the wiring from your existing light fitting, Pull the mains wire through the hole and directly plug to the connection block inside the quick fit connection case in the following way. No tools are necessary.

    SUPPLY

    LIGHT FITTING

    Red Green Blue

    SWITCHED LIVE

    Brown

    EARTH Yellow Green

    NEUTRAL

    Blue

    Check that…
    · You have correctly identified the wires. · The connections are tight. · No loose strands have been left out of
    the connection block.

    Technical data

    Supply Voltage:

    220-240 V~, 50 Hz

    Bulb

    99566—12W LED module (SMD) CCT, 3000K / 4000K / 6000K

    Type: 99767—24W LED module (SMD) CCT, 3000K / 4000K / 6000K

    This product contains a light source of energy efficiency class D.

    Non-replaceable light source

    Non-replaceable control gear

    Conformity with all relevant UKCA Directive requirements.

    Conformity with all relevant EC Directive requirements.

    This product is Class 1, must be connected to earth.

    Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.

    This product is not suitable for dimming.

    IP44

    This product is rated at IP44.

    IK08 This product is rated at IK08.

    Care and Safety
    We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. Shade – Remove and wash in warm water or just use a damp cloth. For your safety, always switch off the power supply before cleaning.

    Replace Cracked Shade

    This bulb is protected by a shade. This part must be replaced immediately should the shade become cracked or damaged. This fitting must not be used without the shade in place.

    For further information, please visit https://www.lighting-info.co.uk/99566

    V1 22/10/2021 UK Manufacturer: BH17 7BY EU Manufacturer: Brilliant AG, Brilliantstrasse 1, D-27442 Gnarrenburg

    Instruction manual
    Nimbus CCT
    99566, 99767
    www.saxbylighting.com

    Thank you for purchasing this light fitting. Please read the instruction carefully before use to ensure safe and satisfactory operation of this product. Please retain these instruction for future reference.
    Warning This is a Class 1 product and must be earthed. Please read these instructions carefully before commencing any work. This unit must be fitted by a competent and qualified electrician. Install in accordance with the IEE Wiring regulations and current Building Regulations. Check the pack and make sure you have all the parts listed. To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. This light fitting should be connected to a circuit with a 30mA RCD fitted. If replacing an existing fitting, make a careful note of the connections. This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped. Take care not to drill into any pipes or mains cables beneath the surface during mounting holes preparation. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
    Layout
    Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the junction box and the light fitting. Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged. The mains supply cable must have a minimum cross section area of 1.0mm2. Cables must be protected using suitable conduit or plastic trunking. This product has special protection against the ingress of moisture and is IP44 rated. This product is suitable for use in Zone 2 and outside zones of a bathroom. Please see diagram. If this unit is being fitted in a room containing a bath or shower, a 30mA RCD must be used – in accordance with IEE regulations.
    2.25m Zone 1 0.6m Outside zones

    Zone 2

    0.6m
    Zone 2

    Installation

    Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires. Note that the power needs to be isolated/switched off at the fuse board. Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.

    · Turn the Metal plate æ counterclockwise to remove from lamp body ç .

    · Using the Metal plate æ as a template, mark and drill the fixing holes.

    A

    Then fix plastic plugs supplied to into the celling. Ensure the ceiling is

    capable of holding the weight of the product. Take care to avoid damaging

    any concealed wiring and pipes.

    1

    · Wire as detailed Wiring diagram.

    · Fix the Metal plate to the celling using the screws supplied.

    · There are three colour rings supplied. Select suitable colorful ring to fix to

    2

    the lamp body, convex è aim at grooves éof lamp body.

    · Dip switch to the favorite color temperature, and follow the instructions ë to install the lamp body into Metal bottom plate æ in right direction.
    · Replace fuse or circuit breaker and switch on. Your light is now ready for use.

    B

    C

    Plug the cables directly to wire fast

    Brown(L) GND ( ) Blue (N)

    Live:Brown or Red GND:Yellow Green Neutral:Blue or Black

    Danger!High Voltage Wire stripping length

    11-13mm

    D

    E

    3

    4

    Three colour rings supplied: Red / Blue / Yellow
    F

    5 6
    WW CW DW

    This product is colur changing and can be either WW (3000K) or CW(4000K) or DW (6000K).
    Choose your preferred colour before installing by using the CCT switch on the back of the lamp body.

    WW CW DW

    CCT Switch

    References

    Documents / Resouces

    Download manual
    Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


    Related Manuals