Simalube 27764029 Automatic Single-point Lubricator Instruction Manual

Simalube 27764029 Automatic Single-point Lubricator Instruction Manual

simalube 27764029 Automatic Single-Point Lubricator LOGO

simalube 27764029 Automatic Single-Point Lubricator simalube 27764029 Automatic Single-Point Lubricator PRODUCT

Calculation and preparation of lubrication pointsimalube 27764029 Automatic Single-Point Lubricator FIG 1

Use „Calculation Pro“ to choose correct dispensing time and lubricator size.
(“Calculation Pro” is available at www.simatec.com, in the App Store, and in the Android Market.) simalube 27764029 Automatic Single-Point Lubricator FIG 2Clean lubrication pointsimalube 27764029 Automatic Single-Point Lubricator FIG 3

Remove connector nipple and screw in quick connection coupling simalube 27764029 Automatic Single-Point Lubricator FIG 4

Connect hose and prefill with a grease gun
(fill tubes completely)

Install and activate simalube and IMPULSEsimalube 27764029 Automatic Single-Point Lubricator FIG 5

Connect hose to mounting bracket simalube 27764029 Automatic Single-Point Lubricator FIG 6

Seal IMPULSE and screw onto lubrication point
ATTENTION: IMPULSE logo must face the front simalube 27764029 Automatic Single-Point Lubricator FIG 7

Cut off plug from lubricator or remove black plug simalube 27764029 Automatic Single-Point Lubricator FIG 8

Activate calculated dispensing time with 3 mm Allen key

simalube 27764029 Automatic Single-Point Lubricator FIG 9

Write in activation date simalube 27764029 Automatic Single-Point Lubricator FIG 10

Insert the battery pack simalube 27764029 Automatic Single-Point Lubricator FIG 11

Screw on lubricator, device will be activated, green LED will blink 2x. The first pump cycle will begin within 30 seconds simalube 27764029 Automatic Single-Point Lubricator FIG 12

Check simalube and IMPULSE regularly

Replace and recycle the lubricatorsimalube 27764029 Automatic Single-Point Lubricator FIG 13

Replace or refill the empty lubricator simalube 27764029 Automatic Single-Point Lubricator FIG 14

a) Remove cover disk
b) Remove gas generator with a socket wrench (SW21 mm) simalube 27764029 Automatic Single-Point Lubricator FIG 15

Dispose of intact gas generator in battery recycling and empty housing in plastic recycling.
(Warning: dispose of leftover grease separately) simalube 27764029 Automatic Single-Point Lubricator FIG 16

Remove the used battery pack and replace it with a new one

Put IMPULSE with new lubricator into operationsimalube 27764029 Automatic Single-Point Lubricator FIG 17simalube 27764029 Automatic Single-Point Lubricator FIG 17

Check and clean the gasket IMPULSE remains on lubrication point simalube 27764029 Automatic Single-Point Lubricator FIG 18

Screw refilled or new lubricator onto the lubrication point

Period of use of the simalube IMPULSE: simalube 27764029 Automatic Single-Point Lubricator FIG 19

simatec ag
Stadthof 2
CH-3380 Wangen a. Aare
Tel.: +41 (0)32 636 50 00
Fax.: +41 (0)32 636 50 19
[email protected]