GENEQ CC4648-000 Vaccine Fridge Thermometer Temperature Monitoring System

FEATURES
- Triple display for current, minimum, and maximum temperature
- Programmable low and high alarm limit
- Outdoor temperature display
- °C / °F exchange
- Low battery indication
- Foldaway stand
- Mounting keyhole

SPECIFICATIONS
| Measuring range | 0 ~ 50°C / 32 ~ 122°F – internal probe (ambient) – 50 ~ 70°C / -58 ~ 158°F – external probe (bottle) |
| Display accuracy | -20 ~ 50 ± 0.3°C |
| Display resolution | 0.1° |
| Display reading update | 10 seconds |
| Battery | 1.5 volt, type AAA x2 pieces |
| Accessories | 1) Outdoor sensor with 3 meters long and glycol bottle 2) Battery 1.5 volt x2 pieces |
INSTALLATION
- Plug outdoor sensor into the unit.
- Install battery with correct polarity positioning.
- The unit will perform a self-test and then display readings normally after 3 seconds.
- Press (°C/°F) to select the temperature unit.
- Place the unit at the place away from direct sunlight, rain, or extreme heat.
- Click on OUT to display the refrigerator temperature.
OPERATION LOW AND HIGH ALARM LIMIT SETTING
- Press (MODE) to enable alarm setting.
- Press (LO ) to set a low alarm limit
- Press (HI ) to set a high alarm limit
- Press (MODE) to return to the normal display.
- When the current reading is lower or higher than the alarm limit the alarm will sound.
- To stop the alarm sound press any button once. The LO or HI icon will still be flashing until the current reading is within the alarm limit.
- Press ( ) to disable or enable the alarm function.
Holding down the button will increase the value automatically.
RESET MINIMUM (MIN) and MAXIMUM (MAX) READING MEMORY
- In MIN-MAX display mode, press (MIN-RESET) to reset minimum reading memory to the current reading.
- Press (MAX-RESET) to reset maximum reading memory to the current reading.
- Reset the memory once before taking a new minimum or maximum reading.
IN / OUTDOOR TEMPERATURE DISPLAY
Press (IN-OUT) to select outdoor or indoor temperature display.
NOTE:
- When the low battery symbol( )appears, replace the battery with the same type of new battery.
- If the thermometer is not in use for a long period of time then remove the battery from battery compartment to avoid battery leakage.
- If there is an abnormal operation or display then press (RESET) once.