REC Duo 150 Decentralized Heat Recovery Unit
Product Information
The REC Duo 150 is a decentralized heat recovery unit designed
for residential ventilation. It is compliant with the ErP Directive
2009/125/CE and EU Regulation 1253/2014. This double flow unit is
classified as a Residential Ventilation Unit with an energy class A
rating. It features a humidity sensor for improved performance.
The REC Duo 150 is equipped with a ceramic heat exchanger that
accumulates heat from extracted air during the pull cycle and
releases it to fresh air during the push cycle. It is an ideal
solution for noble rooms such as bedrooms and living rooms,
effectively addressing humidity and condensation problems.
Installation Examples
The REC Duo 150 can be installed in two configurations:
- Coupled installation in a single room
- Coupled installation in two separate rooms
Both installation examples offer maximum benefit, providing
efficient heat recovery ventilation.
Operating Scheme
The REC Duo 150 operates in push-pull mode with reverse flow. It
runs for 24 hours in push-pull modality at low speed, which can be
selected between two options during installation. When speed boost
is activated through a remote control switch or RLS controller, the
unit switches to extraction operation modality. The maximum speed
can be set using a timer, adjustable from 0 to 30 minutes. After
the timer concludes, the fan automatically switches back to
push-pull operation modality at low speed.
Models and Operation
| Code | Model | Duct |
|---|---|---|
| 2RC1500 | REC Duo 150 | 158 |
| 2RC1501 | REC Duo 150 MHY | 158 |
| 2RC1502 | REC Duo 150 PLUS RC | 158 |
Performance
*Lp(A) measured at 3 m in open field 230V-50Hz
Usage Instructions
To use the REC Duo 150 PLUS RC, follow these instructions:
- Press the desired button on the remote controller to activate
the corresponding operation modality:
- 0: On/off
- 1: Push-pull operation modality – 24 hours reverse flow running
at the selected speed - 2: Speed 1 – Low speed set up (preset at 35 m3/h)
- 3: Speed 2 – Low speed set up (preset at 50 m3/h)
- 4: Boost speed with timer (extraction mode only)
- 5: Sleep mode – Operation at low speed is frozen for 8 hours to
ensure high acoustic comfort during the night. Press any button
(except button 0) to unblock the function at any time. - 6: Flow control operation – Press once for extraction mode,
press twice for intake mode only. - 7: Free-cooling mode – Air exchange without heat recovery.
Press once to stop the reverse flow and keep the fans running at
the current flow. Press twice to reverse the flow of all fans and
run at the new selected flow.
received the signal every time a button is pressed.
uo
150
Decentralized Heat Recovery Unit Double flow with heat recovery
Coupled installation in a single room or 2 separate rooms
Comply with ErP Directive 2009/125/CE and EU Regulation 1253/2014 Classification: Residential Ventilation Unit.
Energy class A
(with humidity sensor)
Thermal efficiency up to 90% Ø150 Easy Installation and maintenance: – Magnetic coupling/uncoupling
of the unit – External grille with net, installable from
the inside – Telescopic duct Wireless technology (REC duo 150 PLUS RC) Drastic solution to humidity and condensation problems
DESCRIPTION
· Very high efficiency decentralized HRU with heat recovery up to 90%. · Ideal for residential applications and in any environment where it is necessary to ensure a constant
thermal comfort both in summer and in winter. · Suitable for any kind of room. · A coupled installation is recommended to optimize the system’s efficiency, in a single room or in
separate rooms. · Direct exhaust through walls with thickness from 340 to 500 mm (adaptable to other wall
thicknesses from 250 to 1000 mm: see section Dimensions). · Suitable for conveying air to a max. temperature of 40°C.
FEATURES
· Stylish and ultra-slim front cover. Very compact dimensions. · High efficiency ceramic heat exchanger. · Provided with G3-class filters both in intake and in extract, easily removable and
washable. · Free-cooling function. · EC brushless motor. · Complies with EN 60335-2-80, LVD 2014/35/EU, EMC 2014/30/EU. · IPX4 · CE marked
INSTALLATION EXAMPLES
Ideal in noble rooms such as bedrooms and living rooms. Maximum benefit with coupled installation.
Bedroom
PRINCIPLE OF OPERATION
REC duo 150 is a “push-pull” HRU with reverse flow. It is provided with a ceramic heat exchanger that accumulates the heat from the extracted air during the “pull” cycle and releases it to the new fresh air during the “push” cycle.
INSIDE
OUTSIDE INSIDE
OUTSIDE
60 REVERSE FLOW
SECONDS
Living room
Coupled installation in 2 separate rooms
OPERATING SCHEME
REC DUO 100 PLUS RC
MASTER
Coupled installation in a single room
Wireless communication
BEFORE
AFTER
Heat Recovery ventilation systems effectively contribute to preventing the mould forming on the walls when this is caused by insufficient natural ventilation.
SLAVE
As far as 6 appliances
SLAVE
SLAVE
MODELS AND OPERATION
REC DUO 150 Cod. 2RC1500
24 hours running in push-pull modality at low speed (selectable between 2 at installation). The unit switches to the extraction operation modality when speed boost is activated through remote control switch or RLS controller (available as accessory). The maximum speed is provided with a timer (adjustable from 0 to 30 minutes). Once concluded the overrun via timer, the fan automatically switches back to the push-pull operation modality at low speed.
REC DUO 150 MHY
Cod. 2RC1501
24 hours running in push-pull modality at low speed (adjustable by the end-user). Boost speed is available in push-pull modality and turns on automatically via humidistat (adjustable from 40 to 90% of R.H) and increases/decreases progressively according to the detected humidity level. In case of a persistent and high concentration of humidity, the unit automatically switches to the extraction operation modality. It then switches back to the push-pull operation modality at low speed when the humidity level goes below the pre-selected threshold. The unit is supplied with a remote controller for the selection and activation of advanced comfort ventilation functions.
RLS Cod. 2RV4158
Available upon request as accessory for REC DUO 150 and REC DUO 150 MHY
– On-Off – Boost speed
RC
REC DUO 150 PLUS RC Cod. 2RC1502
REC DUO 150 PLUS RC is supplied with a remote controller, to select the speed and activate the following operation modalities:
24 hours running in push-pull modality at low speed (selectable between 2 at installation). The unit switches to the extraction operation modality when speed boost is activated, manually or automatically: Manually via control switch or RLS controller (available as accessory). The maximum speed is provided with a timer (adjustable from 0 to 30 minutes). Once concluded the overrun via timer, the fan automatically switches back to the push-pull operation modality at low speed. Automatically via humidistat (adjustable from 40 to 90% of R.H). The fan speed increases/decreases according to the humidity level detected above the pre-selected threshold. It then switches back to the push-pull operation modality at low speed when the humidity level goes beneath the pre-selected threshold.
0 On/off
1 – Push-pull operation modality 24 hours reverse flow running at the selected speed
2 – Speed 1 Low speed set up (preset at 35 m3/h)
3 – Speed 2 Low speed set up (preset at 50 m3/h)
4 – Boost speed with timer (extraction mode only)
5 – Sleep mode the operation at low speed is frozen for 8 hours to ensure high acoustic comfort during the night. The function can be unblocked at any time by pressing any button (except button 0).
6 – Flow control operation in intake or extract mode only. Press once: extraction mode. Press twice: intake mode
7 – Free-cooling mode: air exchange without heat recovery. No reverse flow. Press once: the reverse flow stops and the fans go on running at the current flow. Press twice: all fans reverse their flow and go on running at the new selected flow.
Led signal: any time a button is pressed, a led switches on the remote controller to indicate that the signal has been received.
PERFORMANCE
CODE
MODEL
DUCT
Ø (mm)
2RC1500 REC Duo 150
158
2RC1501 REC Duo 150 MHY
158
2RC1502 REC Duo 150 PLUS RC
158
*Lp(A) measured at 3 m in open field 230V-50Hz
WALL THICKNESS
min-max (mm) 340 – 500 340 – 500 340 – 500
AIRFLOW min / max / only exhaust
m3/h 35 / 50 / 70 35 / 50 / 70 30 / 60 / 70
l/s 9,8 / 13,9 / 19,4 9,8 / 13,9 / 19,4 8,3 / 16,6 / 19,4
W min / max / only exhaust
2,2 / 3,8 / 6,2 2,2 / 3,8 / 6,2 1,6 / 5,7 / 6,2
dB (A)*
Lp 20 / 28 / 31 20 / 28 / 31 17 / 30 / 31
200 Ø149 Ø158 Ø186
DIMENSIONS (mm)
External grille installable from the inside
200
57 20
15 340 – 500 250 – 1000 ( I )
(I) For walls with thickness > 500 mm: It is necessary to use the telescopic duct available as accessory Cod. 2KT0015
For wall thickness between 250 and 340 mm: it is necessary to cut the duct and to use the external grille MFE, available as accessory Cod. 2GE2005