Winegard Ds2000s Universal Mount W Adapter Plate User Guide

DS2000S Universal Mount w Adapter Plate

Product Information:

The Universal Mount w Adapter Plate DS2000S is a mounting system
designed for TV antennas. It includes U-bolts, an adapter plate,
flanged hex nuts, and a pipe & foot assembly. The mount is used
to securely attach the antenna to a wall or other solid
surface.

Product Usage Instructions:

  1. Locate a stud in the area where you want to install the
    mount.
  2. Drill a small pilot hole to help start threading the lag bolts
    (5/16x 3 recommended).
  3. Apply silicone sealant to the back of the base to seal
    holes.
  4. Use the lag bolts to tighten the base to the wall, ensuring
    that the mast is plumb.
  5. Insert the U-bolts through the slots in the adapter plate and
    secure loosely with the nuts.
  6. Position the adapter plate facing up and place the bottom
    U-bolt over the antenna mount pipe. Tighten the two bottom U-bolt
    nuts.
  7. Slide the auxiliary pipe through the upper U-bolt and into the
    antenna mount pipe as far as possible. The second guide rests on
    the top edge of the pipe mount. Tighten the nuts on the upper
    U-bolt until the pole is secure. Verify that the bottom U-bolt is
    also secure.

WARNING: Installation of this product near
power lines is dangerous. Follow the installation instructions for
your safety.

Lightning Protection Instructions:

  1. Mount the lightning arrestor as close as possible to where the
    downlead enters the house.
  2. The ground wires for both the mast and the downlead should be
    copper or aluminum wire, number eight (8) or larger.
  3. Secure the downlead wire from the antenna to the lightning
    arrestor every four (4) to six (6) feet to prevent whipping.
  4. If the mast extends four or more feet into the ground for a
    ground-up antenna installation, it may not be necessary to ground
    the mast. Consult a TV serviceman for proper depth in your
    location.

For more product information, warranty details, or assistance,
you can scan the provided QR code or contact Winegard Company at
800-288-8094.

Winegard Company is not affiliated with Starlink, Space
Exploration Technologies Corp., or any other trademark or
registered trademark mentioned in this manual.

Universal Mount w Adapter Plate DS2000S
INSTALLATION Not provided: 7/16″ wrench, lag bolts

CONTENTS:
2 – U-bolts 1 – Adapter plate 4 – Flanged hex nuts 1 – Pipe & foot assembly

stud a

b

lag holes

(5/16″x 3″ lag screw

recommended)

If siding is heavy enough, the outer holes can also be used to help secure the base.

1.0″ ­ 1.5″ auxiliary pipe dia. or Starlink
d

c

Quick Start Guide
1 LOCATE a stud in the area to be installed.
2 DRILL a small pilot hole to help start threading the lag bolts (5/16″x 3″ recommended) (a).
3 APPLY silicone sealant to the back of the base to seal holes (b).
4 USE the lag bolts to tighten the base to the wall. Make sure the mast is plumb.
5 INSERT the U-bolts through the slots in the adapter plate and secure loosely with the nuts (c).
6 POSITION the adapter plate facing UP, and place the bottom U-bolt over the antenna mount pipe (c). Tighten the two bottom U-bolt nuts.
7 SLIDE the auxiliary pipe through the upper U-bolt and into the antenna mount pipe as far as possible (d). The second guide rests on the top edge of the pipe mount. Tighten the nuts on the upper U-bolt until the pole is secure. Verify the bottom U-bolt is also secure. WARNING: INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS. For your safety, follow the installation instructions.
See back for grounding instructions

SCAN FOR

MORE PRODUCT INFORMATION

WARRANTY
OR CALL 800-288-8094

Winegard Company 2736 Mt. Pleasant St. | Burlington, IA 52601
Starlink is a trademark of Space Exploration Technologies Corp. All trademarks, registered trademarks and logos are the property of their respective owners and are not affiliated with Winegard Company.

Printed in U.S.A. © 2022 Winegard Company Rev 9-22 2452507

HOW TO PROVIDE LIGHTNING PROTECTION FOR TV ANTENNA AND SET
STEP 1. Mount the lightning arrestor as close as possible to where the downlead enters the house.
STEP 2. The ground wires for both the mast and the downlead should be copper or aluminum wire, number eight (8) or larger.
STEP 3. The downlead wire from the antenna to the lightning arrestor should be secured every four (4) to six (6) feet to prevent whipping.
NOTE: In the case of a “ground up” antenna installation, it may not be necessary to ground the mast if the mast extends four or more feet into the ground. Consult a TV serviceman for proper depth in your location.

ENxaatimoENnxapaatliemol EnpoallfeelacEontlfertaciecntnratienclnaaCnlgoaCrdogoedruo,enuA, dnANdiNnSiSngIgI//aNNasFsFPpPpAeeArr7700
Anntteennna aLead ILneWadire-in Wire

ElEelcetcrtircic SeSErqevruivcipicemeent Equipment

GCGClralroaommuunnppdd

AAnnteennnnaa Discharge Unit (D(NNiEsEcCChSaSregececttiiUoonnni8t81100–2200))

GGrroouunndd CCllampps

GGroouunnddininggCConodnudctuocrstors ((NNEECCSSeecction 81100-211))

PPoowweer rSSerevricveicGeroGurnoduinngding EElleecctrtordoedSeySstyesmtem
(NEECC Arrtt225500,,PPaarrttHH))

NECNE-CN-aNtaiotionnaall EElleecctrticriacl aCloCdeode