Juno Trac Adapter Instruction Manual

Trac Adapter

Product Information:

The Juno Trac Adapter is a versatile accessory that allows for
easy installation of fixtures onto Juno track systems. It is
compatible with various sizes and styles of Juno Trac adapters.

Key Features:

  • Easy installation
  • Compatible with Juno track systems
  • Versatile design

Product Usage Instructions:

Fixture Installation:

  1. Find the latch and the polarity line on the adapter box.
  2. Align the parts as shown in Fig. 1.
  3. Insert the adapter box into the track.

    Figure 1 - Fixture Installation

  4. Pull down the latch while rotating the adapter box 90 degrees
    clockwise.

    Figure 2 - Fixture Installation

  5. The latch should snap into place between the extrusion rails.
    Ensure that the arrows on the latch point toward the polarity
    line.

    Figure 3 - Fixture Installation

Second Circuit Positioning:

  1. Raise the contact marked P (on switch side) by inserting a thin
    screwdriver blade under the contact. Pull it up into position as
    shown in Fig. 4.

    Figure 4 - Second Circuit Positioning

  2. Insert the contact support (supplied with the 2-circuit Trac
    section) by tilting and snapping it into position under the P
    contact as shown in Fig. 5.

    Figure 5 - Second Circuit Positioning

  3. Ensure that the contact support is snapped and locked into
    position as shown in Fig. 6.

    Figure 6 - Second Circuit Positioning

Troubleshooting:

If you encounter any issues with the fixture, refer to the
following troubleshooting steps:

ProblemCauseRemedy
Fixture doesn’t turn onTrack not energized
Adapter switch is in the Off position
Fixture installed incorrectly
Ensure track has power
Ensure the power switch on the track fixture adapter is in the On
position, see Fig. 9
Ensure fixture is installed correctly, with the arrows on the latch
pointing towards the polarity line as shown in Fig.
3
P Contact adjusted incorrectlyEnsure P contact isn’t bent from adjusting incorrectly, see
Fig. 8
Bent contact from adjusting the wrong contact, see Fig.
4
, 5, & 6 for proper
adjustment method
Adjust the P contact correctly as shown in Fig.
8

Note: The correct single circuit and two circuit positions are
shown in Fig. 8 and Fig. 9
respectively.

Always make sure the switch on the adapter is in the On position
for proper functionality.

For further assistance, refer to the complete user manual or
contact customer support.

INSTALLATION INSTRUCTIONS
For Juno Trac Adapter*

WARNING Read all of these installation instructions before installing.
SAVE THESE INSTRUCTIONS

FIXTURE INSTALLATION Step 1 Find the latch and the polarity line. Align parts as shown and insert the adapter box into the track. (Fig. 1)

Fig. 1
LATCH

POLARITY LINE

Fig. 2

Coming Soon

Step 2 Pull down the latch while rotating the adapter box 90 degrees clockwise. (Fig. 2)

Step 3 Final Position: Latch snaps into place between extrusion rails. Arrows on latch point toward the polarity line. (Fig. 3)

Fig. 3

SECOND CIRCUIT POSITIONING
Step 1 Raise the contact marked “P” (on switch side) by inserting a thin screwdriver blade under contact. Pull up into position as shown. (Fig. 4)

(INSERT)

(PULL)

(ROTATE)

Fig. 4
“P” CONTACT

(LIFT)

Step 2 Insert contact support (supplied with 2-circuit Trac section) by tilting and snapping into position under the “P” contact as shown. (Fig. 5)

Fig. 5

Step 3 Ensure contact support is snapped and locked into position. (Fig. 6) Follow instructions for inserting into track.

CONTACT SUPPORT

Fig. 6

FINAL POSITION OF CONTACT SUPPORT

*Juno Trac adapter size and style may vary.

One Lithonia Way · Conyers, GA 30012 · 1-800-705-SERV (7378) · www.acuitybrands.com

©2020 Acuity Brands Lighting, Inc.

P6300 Rev 10/2022

1 of 2

Coming Soon

INSTALLATION INSTRUCTIONS
For Juno Trac Adapter*

TROUBLESHOOTING

Problem
Fixture doesn’t turn on

Cause Track not energized Adapter switch is in the
“Off” position
Fixture installed incorrectly

Remedy Ensure track has power
Ensure the power switch on the track fixture adapter is in the “On” position, see Fig. 9
Ensure fixture is installed correctly, with the arrows on the latch pointing towards the polarity line as shown in Fig. 3
Ensure contacts aren’t bent from installing the fixture incorrectly, see Fig. 7

Fig. 7

“P” Contact adjusted incorrectly

Ensure “P” contact isn’t bent from adjusting incorrectly, see Fig. 8
Bent contact from adjusting the wrong contact, see Fig. 4, 5, & 6 for proper adjustment method

Correct

Single Circuit Position
Used with T, TU, and R Series Track

Incorrect

Bent Contact

Raised Contact

Fig. 8

Correct

Two Circuit Position
Used with TU Series Track

Incorrect

Bent Contact

Raised Contact

Fig. 9

Move Switch To “On” Position

Off

On

One Lithonia Way · Conyers, GA 30012 · 1-800-705-SERV (7378) · www.acuitybrands.com

©2020 Acuity Brands Lighting, Inc.

P6300 Rev 10/2022

2 of 2