levenhuk MC60 Wezzer Air Quality Monitor User Manual
Overview

- Power button
- UP button
- DOWN button
- Micro USB port
- Current CO2 value (ppm)
- Temperature
- Humidity
Caution! Please remember that mains voltage in most European countries is 220–240V. If you want to use your device in a country with a different mains voltage standard, remember that use of a converter is absolutely necessary.
Charging the device
Connect the micro USB cable to the device. Then, with a DC adapter (not included) via a USB plug connect it to the AC power supply. Attention! The device operates from the AC power supply, as the voltage of the computer’s USB port is insufficient for the proper operation of the device.
Using
Press (1) for 3 seconds to turn the device on/off.
Settings
Press (1) twice. Press (2) or (3) to change the value, and then press (1) to continue.
The setting order: date > time > temperature unit (°C/°F) > alarm sound on/off > temperature offset.
History record
Press (2)/(3) to navigate the trend screen. The graph shows the last 5 CO2 data values every 10 minutes over the past 50 minutes.
CO2 scale
| Air quality level | Current CO2 value (ppm) | Indication |
| Good normal outdoor air CO2 level | 400–800 | Green |
| Ok ventilation is recommended | 800–1200 | Yellow |
| Poor is associated with such symptoms as headache, sleepiness, poor attention, increased heart rate, and nausea | 1200–5000 | Red |
Specifications
Operating CO2 range: 400–5000ppm
Air humidity, units of measurement: % (RH)
Operating humidity range: 20… 85%
Temperature, units of measurement: °C, °F
Operating temperature range: –10… +50°C (+14… +122°F)
Power supply: Li-ion battery (3000 mA∙h), DC adapter 5V 1000mA (not included)
Micro USB cable: included
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Take the necessary precautions when using the device with children or others who have not read or who do not fully understand these instructions. Make sure that the air flow channels at the back of the device are not blocked or covered. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts!
If a part of the device or battery is swallowed, seek medical attention immediately. Children should use the device under adult supervision only.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met.
For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.
References
Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
Levenhuk optical instruments store | Levenhuk - best optical equipment
Levenhuk lifetime warranty details | Levenhuk - best optical equipment
Doživotní záruka společnosti Levenhuk – Oficiální webové stránky Levenhuk pro Českou republiku
Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
Garantía internacional de por vida Levenhuk – Compre desde el sitio web oficial de Levenhuk en España
Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
Gwarancja bezterminowa Levenhuk – Oficjalna witryna internetowa Levenhuk w Polsce
Поддержка - Гарантийное обслуживание Левенгук - Levenhuk Russia