Futaba Gy701 Data Copy Tool Instructions

GY701 Data Copy Tool

Product Information

Product Name: GY701/CGY750V2.0 Data Copy Tool

Model Number: 1M23Z03008

Features

The GY701/CGY750V2.0 data copy tool allows you to store and
transfer setting data between the GY701 or CGY750V2.0 and your
PC.

Caution: The data copy tool is compatible with the following
firmware versions of the GY701 and CGY750V2.0:

  • GY701 Ver: 1.10 or later
  • CGY750 Ver.2.00 or later (Please use the previous version for
    Ver.1.20 – 1.40. For CGY750 Ver.2.0 and later, the previous version
    may not work correctly.)

Connection

  1. Connect the CIU-2/CIU-3 to the USB connector of your PC and the
    other end to the S.BUS input terminal of GY701/CGY750V2.0.
  2. Supply power to GY701/CGY750V2.0.

Note: Prior to operation, make sure to install the PC drivers of
the CIU-2/CIU-3 to your PC and decompress the downloaded GYLink
software.

Product Usage Instructions

Storing Setting Data to PC

  1. Run the GYLink.exe software that you downloaded.
  2. A dialogue box will appear when GYLink starts properly.
  • If the PC cannot recognize the CIU-2/CIU-3, an error message
    will appear. In this case, check the proper connection of the
    CIU-2/CIU-3 and ensure that the PC driver software is installed
    correctly.
  • Click the [READ] button on the box.
    • The PC will prompt you to select the destination folder and
      file name for storing the data.
    • Choose the desired folder on your PC and click the [Save] button. The box will show [Now reading…].
  • Once the reading process is complete, the box will display the
    model type and ID number.
    • If you encounter a read error message or the box does not show
      the ID number, ensure the wire connection and power supply are
      correct, and then retry the reading process.

    Transferring Setting Data to GY701/CGY750V2.0

    1. Run the GYLink.exe software that you downloaded.
    2. A dialogue box will appear when GYLink starts properly.
    • If the PC cannot recognize the CIU-2/CIU-3, an error message
      will appear. In this case, check the proper connection of the
      CIU-2/CIU-3 and ensure that the PC driver software is installed
      correctly.
  • Click the [WRITE] button on the box.
    • The PC will prompt you to select the destination folder and
      file name for the data transfer.
    • Select the file name and click the [Open] button on the box.
      The box will show [Now writing].
  • Once the transfer is completed, [The writing succeeded] will be
    displayed.
    • If a writing error message appears, try the writing process
      again.

    Contact Information:

    FUTABA CORPORATION

    Phone: +81 475 32 6982

    Facsimile: +81 475 32 6983

    1080 Yabutsuka, Chosei-mura, Chosei-gun, Chiba-ken, 299-4395,
    Japan

    Date: 2016, 6 (2)

    1M23Z03008
    The instruction of GY701/CGY750V2.0 Data copy tool
    1. The feature of GY701/CGY750V2.0 data copy tool Setting data of the GY701 or CG750V2.0 can be stored to PC. Setting data that are stored to the PC can be transferred to GY701 or CGY750V2.0.
    Caution: Data copy tool can work with later firmware version of the GY701 and CGY750V2.0 as listed below. Please update the GY701 and CGY750V2.0 prior to use this tool.
    GY701 Ver: 1.10 or later CGY750 Ver.2.00 or later (Please use the previous version for Ver.1.20 – 1.40. For instead of At CGY750 Ver.2.0 and later, the previous version can not work correctly.)
    2. Connection 1). Connect the CIU-2/CIU-3 to USB connector of the PC and other end to S.BUS input terminal of GY701/CGY750V2.0. 2). Supply the power to GY701/CGY750V2.0.
    * PC drivers of the CIU-2/CIU-3 must be installed to the PC prior to the operation. * Decompress the download file of the GYLink software.
    3. Direction of storing the setting data of the GY701/CGY750V2.0 to PC. 1). Run the GYLink.exe of downloaded software. 2). Dialogue box will appear when the GYLink start properly as below. The error message will appear when the PC can not recognize the CIU-2/CIU-3 as right below. In this case, check the CIU-2/CIU-3 is connected properly or the PC driver software are installed properly.
    3). Push the [READ] button on the box. PC will ask you the destination folder and file name it is to be stored.
    4). Put the file name to the desire folder of your PC and push the [Save] button. The box shows [Now reading…].

    5).Once the reading process is complete, the box shows model type and ID number. When you have Read error message or box does not show the ID number, make sure the wire connection and power supply and retry the reading process again.
    4. Direction of transferred the setting data on the PC to GY701/CGY750V2.0. 1). Run the GYLink.exe of downloaded software. 2). Dialogue box will appear when the GYLink start properly as shown below. The error message will appear when the PC can not recognize the CIU-2/CIU-3 as right below. In this case, check the CIU-2/CIU-3 is connected properly or the PC driver software are installed properly.
    3). Push the [WRITE] button on the box. PC will ask you the destination folder and file name it is to be transferred. 4). Select the file name and push [Open] button on the box. The box shows [Now writing]. When the transferred is completed, [The writing succeeded] is showed. In case of writing error message is appeared, try the writing process again.
    FUTABA CORPORATION Phone: +81 475 32 6982, Facsimile: +81 475 32 6983 1080 Yabutsuka, Chosei-mura, Chosei -gun, Chiba-ken, 299-4395, Japan 2016, 6 (2)

  • Documents / Resouces

    Download manual
    Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


    Related Manuals