Fanmaster Asp-500-mf2 Masterfilter Air Scrubber Purifier Instruction Manual

ASP-500-MF2 Masterfilter Air Scrubber Purifier

Product Information

The Fanmaster Masterfilter air scrubber purifier is an
industrial-grade appliance designed to remove particles from the
air and surrounding surfaces, as well as eliminate odors. It
features a two-stage filtration process that captures 99.97% of
airborne particles, including dust, allergens, bacteria, and
viruses. The appliance is equipped with a UV-C light sterilization
function that deactivates the DNA of microorganisms, preventing
their ability to multiply and spread.

The ASP-500-MF2 model has a rated power of 0.21KW and operates
on AC220-240V/50Hz. It has an air flow rate of 241 L/s (CFM) and a
noise level of 78 dBa. The appliance weighs 15.5 kg and has
dimensions of (W)438x(D)328x(H)412 mm.

Product Usage Instructions

  1. Safety Precautions: Before using the
    appliance, carefully read and understand all the safety rules and
    warnings provided in the instruction manual.
  2. Disposal Guidelines: Do not dispose of the
    product with general household waste. Follow the laws governing
    Waste Electrical and Electronic Equipment for proper disposal.
    Contact local authorities for information on disposal
    facilities.
  3. Assembly: Remove the appliance from the
    carton. If any damage is observed, contact Fanmaster or the place
    of purchase for assistance.
  4. Filter Assembly: Open the cover by releasing
    the two latches. Remove the plastic packaging from all filters.
    Failure to do so may cause risks or damage to the appliance.
  5. Operation: Place the appliance in the desired
    location. Connect the appliance to a suitable power source using
    the provided 3-pin plug. Ensure the cable length is appropriate for
    your setup.
  6. Working Principle: The ASP-500-MF2 draws
    contaminated air into the air inlet, which then passes through a
    two-stage filtration process. The first stage involves the G4
    Pleated Disposable Cardboard Filter, which captures initial dust
    and allergen particles. The second stage utilizes the H13 HEPA
    Filter, which captures smaller particles up to 0.3 microns and
    helps control bacteria and mold growth. After filtration, the UV-C
    Light sterilizes the filtered air by deactivating microorganisms’
    DNA.
  7. Air Outlet: The clean, filtered air is
    expelled back out through the air outlet.
  8. Filter Replacement Indicator: The appliance is
    equipped with a filter replacement indicator light that illuminates
    when the HEPA filter needs to be replaced. Monitor this indicator
    and replace the filter accordingly.

For further details on product usage, maintenance, and
troubleshooting, refer to the complete instruction manual provided
with your purchase. Keep this document for future reference.

FANMASTER
cooling heating ventilation extraction
INSTRUCTION MANUAL
MASTERFILTER AIR SCRUBBER PURIFIER
MODEL: ASP-500-MF2
SCAN ME
TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS & INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS

FOR YOUR INFORMATION
Thank you for purchasing a Fanmaster Masterfilter air scrubber purifier. Please read this instruction manual carefully before using this appliance.
Disclaimer: Fanmaster reserves the right to make alterations to specifications, quantities, dimensions, for production or other reasons, subsequent to publication. While we believe the information is accurate and complete, we make no warranty or representation for any particular purposes. The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warnings in this document is at the sole discretion and risk of the user.
Disposal Guidelines: Do not dispose of this product with general household waste. This product must be disposed according to the laws governing Waste Electrical and Electronic Equipment. If required, contact your local authorities for information regarding the available disposal facilities.

1. GENERAL SAFETY RULES & WARNINGS
· PLEASE READ INSTRUCTIONS CAREFULLY. · PLACE INSTRUCTION MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. DO NOT ALLOW
ANYONE WHO HAS NOT READ THESE INSTRUCTIONS TO ASSEMBLE, ADJUST OR OPERATE THIS APPLIANCE. · IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT IN CAUSING PROPERTY DAMAGE, SERIOUS INJURY OR LOSS OF LIFE. · FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS APPLIANCE, CAN RESULT IN DEATH, SERIOUS INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, AND/OR ELECTRICAL SHOCK. · ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS APPLIANCE. IF YOU NEED ASSISTANCE OR REQUIRE INFORMATION SUCH AS AN INSTRUCTION MANUAL, LABELS, ETC. CONTACT FANMASTER. · DO NOT STORE OR USE GASOLINE, PETROL OR ANY OTHER FLAMMABLE OR COMBUSTIBLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS APPLIANCE. · THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE IS CONNECTED MUST COMPLY WITH LOCAL REGULATIONS. A RESIDUAL-CURRENT DEVICE (RCD) MUST BE INSTALLED. · UNPLUG THE APPLIANCE BEFORE PERFORMING ANY MAINTENANCE OPERATIONS. · ALWAYS CHECK THE POWER CABLE BEFORE USING THE APPLIANCE. IT MUST NOT BE BENT, TAUT, STRETCHED, CRUSHED OR ANY WAY DAMAGED. · IF THE POWER CORD AND/OR PLUG IS DAMAGED, IT MUST BE REPLACED BY FANMASTER, A SERVICE AGENT OR A QUALIFIED PERSONS. · DO NOT LEAVE THE APPLIANCE UNATTENDED WHEN IN USE. · NEVER USE THE APPLIANCE WITH WET HANDS OR WHEN EITHER THE APPLIANCE OR THE POWER CABLE IS WET. · CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. · THE APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LOCK OF EXPERIENCE & KNOWLEDGE. · PLEASE MAKE SURE ALL PLASTIC PACKAGING IS REMOVED FROM ALL FITLERS BEFORE OPERATION. · THIS APPLIANCE CONTAINS A UV EMITTER. DO NOT STARE AT THE LIGHT SOURCE. · DO NOT USE AN ADAPATER WITH THIS APPLIANCE. · BREATHING HAZARD – WHEN USING THIS APPLIANCE IN A CONTAINMENT AREA, ALWAYS TURN OFF POWER TO OPEN COMBUSTION APPLIANCES SUCH AS FIREPLACES, FURNACES, WATER HEATERS & HVAC SYSTEMS TO AVOID THE RISK OF BACK-FLOW CARBON MONOXIDE FUMES. · IF THE FILTER CHANGE LIGHT ILLUMINATES DURING THE REMEDIATION PROCESS, IMMEDIATELY CHANGE THE HEPA/ACTIVATED CARBON FITLER. · TIPPING HAZARD – ONLY STACK THIS UNIT IN STORAGE, NOT IN USE. DO NOT STACK MORE THAN TWO (2) UNITS ON TOP OF EACH OTHER. · THIS APPLIANCE IS NOT DESIGNED TO BE CONTINUOUSLY USED 24 HOURS 7 DAYS A WEEK AS IT WILL SHORTEN THE PRODUCT LIFE.

2. PRODUCT DESCRIPTION & SPECIFICATIONS
PRODUCT DESCRIPTION Industrial air scrubber purifier designed to remove particles from the air and surrounding surfaces and odours.

SPECIFICATIONS

MODEL Air Flow (L/s) (CFM) Rated Power Voltage (V/Hz) Current Rating (A) Plug Connection Cable Length (m)
Filters
Filter Size (mm)
Fan Dia (mm) Air outlet Dia (mm) Filtered Aream (m2) Fan Speed Hour Meter Filter Replacement/Clean Indicator Light Noise (dBa) Weight (kg) Product Dimensions (mm) Packaged Dimensions (mm)

ASP-500-MF2 241
0.21KW AC220-240V/50
0.87 3 Pin 10amp
5 1st stage: G4 Pleated Disposable Cardboard Filter 2nd stage: H13 HEPA Filter UV-C Light Sterilisation
Pre Filter: 290x290x22 H13: 280x280x105 220 197 up to 40 Variable Yes
Yes
78 15.5 / 17 (W)438x(D)328x(H)412 (W)505x(D)390x(H)465

· When the unit total working time adds up to 2000 hours, the filter warning light will flash with an alarm on the control panel. (To reset the machine, push the UV-C light switch 3 times continuously in 5 seconds after Reset the filter service time)

· UV-C sterilization lamp fault detection function: when the UV-C sterilization lamp does not work, the alarm will keep ringing.

3. GETTING TO KNOW YOUR APPLIANCE

4. HOW IT WORKS
The ASP-500-MF2 works by drawing the contaminated air into the air inlet which passes through a 2 stage filtration process that removes 99.97% of airbourne particles and is then sterlised with a UV-C Light.
The clean filtered air is then expelled back out via the air outlet. It removes dust particles and other airborne contaminants that carry mould spores, germs, viruses from the air and surrounding surfaces. The ASP-500-MF2 is fitted with a filter replacement indicator which will light up when the HEPA filter needs to be replaced.
Two (2) stage filtration & UV-C Light proces:
1st Stage: Pre-filter G4 Pleated Disposable Cardboard Filter – captures initial dust & allergen particles.
2nd Stage: H13 HEPA Filter – captures even smaller particles, up to 0.3 microns. Helps control and prevent the growth of bacteria and mould. Capturing 99.97% of dust & allergen particles.
UV-C Light: UV-C Light sterlises the filtered air. UV-C technology works by deactivating the DNA of mircoorganisms like bacteria & viruses disrupting their ability to multiply & spread.
5. USES & APPLICATIONS
USES
· Air purifcation · Dust control · Odour control · Remediation & Restoration works (wate, fire & mould damage)
APPLICATIONS
· Constructions sites · Offices · Commerical – hotels, kitchens · Warehouses, workshops, factories · Rental/Hire

6. ASSEMBLY & OPERATING INSTRUCTIONS
Remove the appliance from the carton. If the appliance is damaged, please contact Fanmaster or where you purchased the appliance from.
ASSEMBLY
There is minimal assembly required. REMOVE PLASTIC PACKAGING FROM FILTERS open the cover via releasing the two (2) latches and remove the plastic packaging from all filters. Failure to do so will cause risks or damage to the appliance. The appliance will not work.
OPERATING INSTRUCTIONS
1. Place the appliance so that it is in an upright vertical position (placed on the rubber feet). 2. Connect the plug to the relevant power source. 3. Open the air inlet cover on the opposite side of the control panel (filters) 4. Turn the appliance on by turning the Variable Speed Control. 5. To turn appliance off turn the Variable Speed Control anti-clockwise.
CONTROL PANEL
Variable Speed Control – controls the air flow (clockwise to increase) Hour Meter – indicates the running time of the unit UVC On/Off – controls the UV-C Lamp Change HEPA Filter – indicates when to replace/clean the HEPA Filter

7. CLEANING, MAINTENANCE & STORAGE
· Before starting any maintenance task, shut down, unplug the appliance. · Do not attempt any electrical repair yourself. If the appliance needs service or
repair, contact a qualified person. · When cleaning, make sure that water does not enter the unit. · Do not open the enclosure to clean the inner parts. Do not spray water into the
appliance. · Never use solvents, gasoline, toluene and similar aggressive chemicals to clean
the appliance.
Regularly wipe the enclosure using a soft sponge or cloth. For very dirty parts, use a sponge wetted with lukewarm water and a mild detergent, then dry using a clean cloth. Clean or replace the filters as required. Check the power cord and plug for any damages, if damaged replace the cord or plug immediately by a qualified person only.
STORAGE · Clean the unit before storing for long periods of time. · Keep stored inside. · Maximum stack of 2 units.
8. WIRING DIAGRAM

9. TROUBLESHOOTING

PROBLEM No Power
No air flow UV-C Lamp not working

CAUSE
Plug is loose or not connected correctly Faulty or damaged power cord Filters are blocked Air inlet or outlet is blocked Drain pipe is clogged Faulty Not positioned correctly

SOLUTION
Check plug connection
Check & replace
Replace filters Check for bloackages Clean out drain pipe Replace Check placement

· When the unit total working time adds up to 2000 hours, the filter warning light will flash with an alarm on the control panel. (To reset the machine, push the UV-C light switch 3 times continuously in 5 seconds after Reset the filter service time)
· UV-C sterilization lamp fault detection function: when the UV-C sterilization lamp does not work, the alarm will keep ringing.

10. WARRANTY
Any claim under this warranty must be made within 12 months of the date of purchase of the product. To make a claim under the warranty, take the product (with proof of purchase) to the store where you purchased the product or go to https://www.fanmaster.com.au/support.
This warranty is given by Fanmaster Pty Ltd ABN: 45 353 934 457 Unit 1/6-8 Yalgar Rd, KIRRAWEE NSW 2232 P: 1300 900 345 E: [email protected]
This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees which cannot be excluded under the Australian Consumer Law. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Exclusions: This warranty does not cover:
· Any defects caused by an accident, misuse, abuse, improper installation or operation, lack of reasonable care, unauthorized modification, loss of parts, tampering or attempted repair by a person not authorized by the distributor.
· Any product that has not been installed, operated or maintained to a satisfactory level.
· Any damage caused by improper power input or improper cable connection.

FANMASTER
cooling heating ventilation extraction
Fanmaster Pty Ltd | 1/6-8 Yalgar Road, KIRRAWEE NSW 2232 1300 900 345 | [email protected] | www.fanmaster.com.au
N11664 MADE IN CHINA

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals