Polar Ct330 Top Loading Bottle Cooler Instruction Manual

Polar Ct330 Top Loading Bottle Cooler Instruction Manual

POLAR LOGO

Top Loading Bottle Cooler
Instruction manual

POLAR CT330 Top Loading Bottle Cooler

Model
CT330 / CT331 / CT332

Safety Tips

  • Position on a flat, stable surface.
  • A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.
  • Consult Local and National Standards to comply with the following:
    – Health and Safety at Work Legislation
    – BS EN Codes of Practice
    – Fire Precautions
    – IEE Wiring Regulations
    – Building Regulations
  • DO NOT use jet/pressure washers to clean the appliance.
  • DO NOT use the appliance outside.
  • DO NOT use this appliance to store medical supplies.
  • DO NOT stand or support yourself on the base, drawers, or doors.
  • DO NOT allow oil or fat to come into contact with the plastic components or door seal. Clean immediately if contact occurs.
  • Bottles that contain a high percentage of alcohol must be sealed and placed vertically in the refrigerator.
  • Always carry, store and handle the appliance in a vertical position and move by holding the base of the appliance.
  • Always switch off and disconnect the power supply to the unit before cleaning.
  • Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.
  • If the power cord is damaged, it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • POLAR recommends that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity, and Functional Testing.
  •  POLAR recommends that this product be connected to a circuit protected by an appropriate RCD (Residual Current Device).

Caution Risk of FirePOLAR CT330 Top Loading Bottle Cooler -ICON

  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
    POLAR CT330 Top Loading Bottle Cooler -WARNINGWarning: Keep all ventilation openings clear of obstruction. The unit should not be boxed in without adequate ventilation.
  • Warning: Do not use mechanical devices or other means to accelerate the defrosting process, other than those
    recommended by the manufacturer.
  • Warning: Do not damage the refrigerant circuit.
  • Warning: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are the type recommended by the manufacturer.

Product Description

CT330 – Polar Top loading Bottle cooler – 935mm Width
CT331 – Polar Top loading Bottle cooler – 1255mm Width
CT332 – Polar Top loading Bottle cooler – 1634mm Width

Introduction

Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.

Pack Contents

The following is included:

  • POLAR Refrigerator
  • Instruction Manual

POLAR prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation

POLAR CT330 Top Loading Bottle Cooler -WARNINGNote: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before the operation. If in doubt allow standing.

  1.  Remove the appliance from the packaging.
    Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces.
  2. Maintain a distance of 20cm (7 inches) between the unit and walls or other objects for ventilation. NEVER LOCATE NEXT TO OR NEAR A HEAT SOURCE.
    POLAR CT330 Top Loading Bottle Cooler -WARNINGNote: Before using the appliance for the first time, clean the interior with soapy water.
  3. Level the appliance by adjusting the screw feet.

Operation

Control PanelPOLAR CT330 Top Loading Bottle Cooler -FIG

Set the Operating Temperature

  1. Hold the SET button for 3 seconds. The value of the current setpoint will be displayed.
  2. Press the POLAR CT330 Top Loading Bottle Cooler -ICON 11or POLAR CT330 Top Loading Bottle Cooler -ICON Mbuttons to display the required temperature.
  3. Press the SET button to store the temperature.

Manual Defrost
Press and hold the defrost button “aux” for 2 seconds to begin a manual defrost. The defrost light illuminates.

Cleaning, Care &Maintenance

POLAR CT330 Top Loading Bottle Cooler -WARNINGSwitch off and disconnect from the power supply before cleaning.

  • Clean the interior of the appliance as often as possible.
  • Do not use abrasive cleaning agents. These can leave harmful residues.
  • Clean the door seal with warm soapy water.
  • Always wipe dry after cleaning.
  • Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
  • Take care when cleaning the rear of the appliance. Sharp edges can be cut.
  • A POLAR agent or qualified technician must carry out repairs if required.

Cleaning the Condenser

  • Periodically cleaning the condenser can extend the life of the appliance.
  • POLAR recommend that a POLAR agent or qualified technician clean the condenser.

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.

Fault

Probable Cause

Solution

The appliance is not workingThe unit is not switched onCheck the unit is plugged in correctly and switched on
Plug and lead are damagedCall POLAR agent or qualified Technician
Fuse in the plug has blownReplace the fuse
Power supplyCheck power supply
Internal wiring faultCall POLAR agent or qualified Technician
The appliance turns on, but the temperature is too high/lowToo much ice on the evaporatorDefrost the appliance
Condenser blocked with dustCall POLAR agent or qualified Technician
Doors are not shut properlyCheck doors are shut and seals are not damaged
The appliance is located near a heat source or airflow to the condenser is being interruptedMove the refrigerator to a more suitable location
Ambient temperature is too highIncrease ventilation or move the appliance to a cooler position
Unsuitable foodstuffs are being stored in the applianceRemove any excessive hot foodstuffs or blockages to the fan
Appliance is overloadedReduce the amount of food stored in the appliance
The appliance is leaking waterThe appliance is not properly leveledAdjust the screw feet to level the appliance (if applicable)
The discharge outlet is blockedClear the discharge outlet
The movement of water to the drain is obstructedClear the floor of the appliance (if applicable)
The water container is damagedCall POLAR agent or qualified Technician
The drip tray is overflowingEmpty the drip tray (if applicable)
The appliance is unusually loudLoose nut/screwCheck and tighten all nuts and screws
The appliance has not been installed in a level or stable positionCheck installation position and change if necessary

Technical Specifications

ModelVoltagePowerCurrentTemperature
Range
RefrigerantDimensions
H x W x D mm
Weight
(kg)
CT330230V 50Hz160W1.4A2°C ” 8°CR600a 55g888 x 935 x 68752.5
CT331230V 50Hz250W1.4A2°C,- 8°CR600a 60g888 x 1255 x 68767
CT332230V 50Hz250W1.4A2°C,,, 8°CR600a 60g888 x 1634 x 68778

Electrical Wiring

POLAR appliances are supplied with a 3 pin BS1363 plug and lead The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:

  • Live wire (colored brown) to the terminal marked L
  • Neutral wire (colored blue) to terminal marked N
  • Earth wire (colored green/yellow) to terminal marked E

POLAR CT330 Top Loading Bottle Cooler -ICON FThis appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency, disconnection is required they must be readily accessible.

Disposal

EU regulations require refrigeration products to be disposed of by specialist companies who remove or recycle all gasses, metal, and plastic components.
Consult your local waste collection authority regarding the disposal of your appliance. Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally.
Alternatively, call the POLAR helpline for details of national disposal companies within the EU.

Compliance

POLAR CT330 Top Loading Bottle Cooler -SYMBOLThe WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.
POLAR CT330 Top Loading Bottle Cooler -ICON WPOLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
POLAR products have been approved to carry the following symbol:

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of POLAR.
Every effort is made to ensure all details are correct at the time of going to press, however, POLAR reserves the right to change specifications without notice.

DECLARATION OF CONFORMITY

  • Conformiteitsverklaring

Equipment Type

Model

G-Series Top loading Bottle cooler – 935mm Width G-Series Top loading Bottle cooler – 1255mm Width G-Series Top loading Bottle cooler – 1634mm WidthCT330 (& -E -A)
CT331 (& -E -A)
CT332 (& -E -A)
Application of Territory Legislation & Council Directives(s)
Toepassing van Europese Richtlijn(en)
Machinery Directive 2006/42/EC

EN 60335-1:2012 +A11:2014 +A13:2017 EN 60335-2-89:2010 +A1:2016 +A2:2017 EN 62233:2008
Electro-Magnetic Compatibility (EMC)
Directive 2014/30/EU – recast of 2004/108/EC EN 55014-1:2017
EN 55014-2:2015 EN 61000-3-2: 2014 EN 61000-3-3: 2013
Restriction of Hazardous Substances Directive (RoHS) 2015/863 amending Annex II to Directive 2011/65/EU

Electrical Safety
IEC 60335-1:2010 +A1:2013 +A2:2015 IEC 60335-2-89:2010 +A1:2012 +A2:2016
Electromagnetic Compatibility
EN 55014-1:2017 EN 55014-2:2015 EN 61000-3-2: 2014 EN 61000-3-3: 2013
Producer NamePolar

I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and Standard(s).

Date3rd December 2020
SignaturePOLAR CT330 Top Loading Bottle Cooler -ICON TPOLAR CT330 Top Loading Bottle Cooler -ICON QPOLAR CT330 Top Loading Bottle Cooler -ICON TTT
Full NameAshley HooperEoghan DonnellanJosie Holt
PositionTechnical & Quality ManagerCommercial Manager/ ImporterCommercial Manager/ Responsible Supplier
Producer AddressFourth Way, Avonmouth, Bristol, BS11 8TB United Kingdom42 North Point Business Park New Mallow Road Cork Ireland15 Bagdally Road, Campbelltown NSW 2560

POLAR CT330 Top Loading Bottle Cooler -CALL

UK+44 (0)845 146 2887
Eire
NL040 — 2628080
FR01 60 34 28 80
BE-NL0800-29129
BE-FR0800-29229
DE0800 — 1860806
ITN/A
ES901-100 133
PT[email protected]

POLAR LOGO

POLAR CT330 Top Loading Bottle Cooler -QR CODE

 http://www.polar-refrigerator.com/POLAR CT330 Top Loading Bottle Cooler -ICON FF

CT330-CT332_ML_A5_v2_20201208
2020/12/8 17:36

POLAR CT330 Top Loading Bottle Cooler -ICON AA

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals