IAQ Pro HEPA Filter Air Scrubber
Product Information:
| Product Name | IAQ Pro HEPA Filter 500CFM Air Scrubber |
|---|---|
| Fan Speed | 1600 rpm |
| Certifications | CE |
| Motor Rating | 450W |
| Power | 230 Volts, 50 Hz |
| Current | 2 amps |
| CFM | 600CFM |
Product Usage Instructions:
- Place the Air Scrubber upright on a level and stable surface
with the handle up. - Remove the dust cover.
- Plug the Air Scrubber into a grounded 230-volt outlet with the
correct voltage and amperage. Use a circuit protected by a ground
fault circuit interrupter for maximum electrical shock protection.
If unsure, consult a qualified electrician or service person. Do
not use an adapter or extension cord. - To switch the unit on, locate the control panel and turn the
variable speed switch clockwise to the desired speed setting.
Ensure that the Air Scrubber operates properly before leaving it
unattended. - Operate the unit until the area is clear of unwanted
contaminants or until filters need to be changed. The control panel
has a filter change light that illuminates when the HEPA filter
needs to be changed. Refer to the section on changing filters for
instructions.
Changing Filters:
WARNING: CONTAMINATION HAZARD
Always wear NIOSH compliant protective gear when changing
filters and dispose of used filters according to your local
regulations.
The IAQ Pro HEPA Filter 500CFM Air Scrubber requires the
following filters:
| Part Number | Description | Qty Req |
|---|---|---|
| MTHF500PF | Pre-Filter | 1 or 2 |
| MTHF500HF | HEPA Filter | 1 |
| MTHF500CF | Optional Charcoal/Carbon Filter | 1 |
Troubleshooting:
PROBLEM: Air Scrubber does not turn on
POSSIBLE CAUSE/SOLUTION: Check if the power
cord is securely plugged into a grounded outlet. Ensure that the
circuit breaker switch is in the ON position. If the problem
persists, consult a qualified technician.
PROBLEM: Air Scrubber starts and then shuts
off
POSSIBLE CAUSE/SOLUTION: Check for any
potential hazards or overload situations. Reset the circuit breaker
switch by pushing the button in. If the issue continues, contact
customer support.
PROBLEM: Air Scrubber vibrates
POSSIBLE CAUSE/SOLUTION: Ensure that the Air
Scrubber is placed on a level and stable surface. Check for any
loose parts or obstructions. If the problem persists, contact
customer support.
PROBLEM: Air Scrubber change light
illuminated
POSSIBLE CAUSE/SOLUTION: It indicates that the
HEPA filter needs to be changed. Refer to the section on changing
filters for instructions.
PROBLEM: Motor makes noises, but Air Scrubber
won’t turn on
POSSIBLE CAUSE/SOLUTION: Check if there are any
blockages in the inlet or outlet ducting. Clean the air pathways
using a slightly damp cloth. If the issue persists, contact
customer support.
IAQ Pro HEPA Filter 500CFM Air Scrubber
The IAQ Pro HEPA Filter 500CFM Air Scrubber is a portable filtration system that removes airborne particles including mold, pet dander, dust, pollen, drywall dust, and other miscellaneous debris as small as 0.3 microns. The IAQ Pro HEPA Filter 500CFM Air Scrubber utilizes up to 3 stages of filtration including a pre- filter, optional 2nd stage, and a HEPA filter. The IAQ Pro HEPA Filter 500CFM Air Scrubber will create cleaner air in any environment. The pre-filter and second stage filter capture larger particles and the HEPA filter captures smaller particles.
WARNINGS
· Do not move or carry the Air Scrubber while it is operating. When the Air Scrubber is operating, the powerful airflow can cause unpredictable movement.
· NEVER allow children to play with or around the Air Scrubber.
· Do not alter or modify your Air Scrubber in any way. Use only replacement parts authorized by Action Solution Products. Modifications or use of unauthorized parts could create a hazard and will void your warranty.
· Store the Air Scrubber in a clean, dry environment. Do not store outdoors or allow water inside the unit’s motor. If the motor becomes wet, allow it to thoroughly dry before use.
· The Air Scrubber should never be operated near water as it will create a risk of serious injury from electrical shock.
· Handle unit with care to avoid causing damage or injury.
· The Air Scrubber should always be operated on a flat surface. Do not operate where unit could fall, or on slippery surfaces, as this could increase the chance of injury, fire, or electrical shock.
· Keep all liquids from being drawn into the Air Scrubber and never operate unit without factory installed safety inlet and outlet grills in place.
· Do not use the Air Scrubber near combustible gas, or hot air as unit could melt and cause a fire or electrical hazard.
· Do not take the Air Scrubber apart or repair it unless you are qualified to do so. Never repair or service unit while Air Scrubber is plugged in.
· Make sure the air intake and outlet are free from all materials and away from obstructions, as any restrictions may cause the Air Scrubber to overheat and cause a shock or fire hazard.
· Unplug the Air Scrubber before performing any service or changing filters
· Do not stack more than 2 units high in order to avoid a tipping hazard falling equipment can cause bodily harm.
OPERATION
1) Place the Air Scrubber upright on a level and stable surface with the handle up.
2) Remove the dust cover.
3) Plug the Air Scrubber into a grounded 230-volt grounded outlet with the correct voltage and amperage. For maximum protection against electrical shock, ALWAYS use a circuit that is protected by a ground fault circuit interrupter. If you are unsure about the outlet, check with a qualified electrician or service person. Do not use an adapter or extension cord.
4) To switch the unit on, locate the control panel and turn the variable speed switch clockwise to the desired speed setting. Check that the Air Scrubber operates properly before leaving it unattended.
5) Operate unit until area is clear of unwanted contaminates or until filters need to be changed. The control panel has a filter change light which illuminates when the HEPA filter needs to be changed. See section on changing filters for instructions.
AUXILIARY/GFCI OUTLET/DAISY-CHAIN
You can interconnect (“daisy-chain”) up to three IAQ Pro HEPA Filter 500CFM Air Scrubber to customize your air filtration needs. The GFCI will “trip” if it detects a sudden “ground fault,” or overload and interrupt the electric current. When the GFCI “trips,” unplug the unit and look for potential hazards such as standing water, frayed cords, or anything that would cause a dangerous electrical problem. If such a situation exists, plug the IAQ Pro HEPA Filter 500CFM Air Scrubber into a different outlet and then push the “reset” button which is located between the 2 outlets on the GFCI. If the unit will not operate check the circuit breaker section below.
CIRCUIT BREAKER SWITCH
The IAQ Pro HEPA Filter 500CFM Air Scrubber is equipped with a circuit breaker switch to protect the Air Scrubber. The switch is located directly above the GFCI outlet and cuts off power to the unit when it detects an unsafe amount of electricity passing through the unit. If the switch “trips,” unplug the unit and look for potential hazards or anything that may be creating an overload situation. “Reset” breaker by pushing button in and continue normal operation.
CHANGING FILTERS
WARNING: CONTAMINATION HAZARD
Always wear NIOSH compliant protective gear when changing filters and dispose of used filters according to your local regulations.
Filters should be changed after every remediation job and whenever the filter change indicator light comes on. The unit should also be cleaned after each job to prevent cross-contamination. Make sure the unit is dry before installing clean filters. To change filters: 1) Unplug the Air Scrubber 2) Open door by releasing sliding latches outward, away from the air scrubber body. 3) Remove used filters and install new filters. 4) Latch door closed and plug the unit in a grounded outlet before operating.
IAQ Pro HEPA Filter 500CFM Air Scrubber SPECIFICATIONS
Fan Speed:
1600 rpm
Certifications:
CE
Motor Rating:
450W
Power:
230 Volts, 50 Hz
Current:
2amps
CFM:
600CFM
Pre-Filter
G4 40x40x2cm
Prime-Filter
H13 48.3×40.5x10cm
Specifications are subject to change without notice.
IAQ Pro HEPA Filter 500CFM Air Scrubber PARTS LIST
Ref
Part Number
Description
Qty Req
1
MTHF5001
Removable Dust Cover
1
2
MTHF5002
Inlet Housing
1
3
MTHF5003
Housing
1
4
MTHF5004
Outlet Grill
1
5
MTHF5005
Airflow Guide
1
6
MTHF5006
1/3 HP Motor
1
7
MTHF5007
Motor Support
1
8
MTHF5008
Motor Seal Panel
3
9
MTHF5009
Switch Panel
1
10
MTHF5010
GFCI Panel
1
11
MTHF5011
Power Cord – 25′
1
12
MTHF500HF
HEPA Filter
1
13
MTHF500PF
Pre-Filter
1 or 2
14
MTHF500CF
Optional Charcoal/Carbon 1
Filter
15
MTHF5015
Foot Pad
4
16
MTHF5016
Pre-Filter Harness
1
TROUBLESHOOTING
PROBLEM Air Scrubber does not turn on
Air Scrubber starts and then shuts off Air Scrubber vibrates
Air Scrubber change light illuminated Motor makes noises, but Air Scrubber won’t turn on
POSSIBLE CAUSE/SOLUTION
· Switch not turned on-turn · Circuit breaker or GFCI has tripped-push rest button · No power to scrubber-make sure unit is plugged in; check
power supply · Faulty switch-replace · Obstructed inlet/outlet remove obstruction · Faulty motor – replace
· Motor shaft is bent replace motor · Fan blade is bent replace · Excessive dirt built up on fan blade clean by wiping with a
slightly damp cloth.
· HEPA filter needs replacement – replace · Air intake restricted remove restriction or bends/kinks in
ducting
· Damaged/faulty motor or motor shaft replace · Broken/loose wire to capacitor tighten · Damaged/faulty capacitor replace · Damaged housing/fan so fan will not spin replace housing
or fan wheel · Motor shaft set screw holding fan wheel is loose – tighten