Monte Carlo 3obsr52xxxd Series Ceiling Fan Installation Guide

3OBSR52XXXD Series Ceiling Fan

Product Information: Product Name: 3OBSR52XXXD Series Fan
Model Number: 3OBSR52XXXD Weight: 6.9 kg (15.18 lbs) Manufacturer:
Monte Carlo Fans Customer Service Contact: 800-969-3347 Customer
Service Center Address: 7400 Linder Ave. Skokie, IL 60077 Website:
www.montecarlofans.com
Product Usage Instructions: 1. Before beginning the
installation, switch off the power at the service panel and lock
the service disconnecting means to prevent accidental power
activation. If the service disconnecting means cannot be locked,
securely attach a warning device, such as a tag, to the service
panel. Only use AC 120V/60HZ power supply. 2. Ensure that the
outlet box is properly installed to the house structure before
installing the fan. Mount the fan to an outlet box or supporting
system that is acceptable for fan support and can support at least
35 lbs (15.88 kg) of weight. 3. Use a metal outlet box suitable for
fan support and only use the screws provided with the outlet box.
Before attaching the fan to the outlet box, ensure that the outlet
box is securely fastened by at least two points to a structural
ceiling member to prevent the fan from wobbling. 4. Install the
mounting bracket onto the outlet box. Partially loosen the two
screws on the outlet box and slide the mounting bracket over the
screws. Position the mounting bracket correctly and tighten the set
screws. 5. Partially loosen the downrod set screws from the yoke at
the top of the motor assembly. Remove the preassembled keeper pin
and cross pin from the downrod. 6. Place the downrod over the
canopy, canopy bottom cap, and yoke cover. Thread the lead wires
and safety cable from the motor assembly through the downrod. 7.
Slip the downrod into the motor housing yoke, aligning the holes.
Install the cross pin and keeper pin. Insert the cross pin through
the yoke and downrod until the point appears on the other side,
then insert the keeper pin on the cross pin. Pull the downrod
tightly against the cross pin and evenly tighten the downrod set
screws on the motor housing yoke. Place the yoke cover on top of
the fan housing. Ensure that the cross pin and keeper pin are
securely installed to prevent serious injury. 8. For Canadian
installations and for fan and light kit combinations over 35 lbs
(15.88 kg) in both flush and downrod modes, the safety cable must
be installed into the house structure beams using the provided lag
screws, washers, and lock washers. Make sure that when the safety
cable is fully extended, the lead wires are longer than the cable
and no stress is placed on the lead wires. Note: Do not remove the
secondary support safety cable during installation in the U.S.
Please refer to the complete user manual for additional
instructions and safety information.

Owner’s Guide and Installation Manual

3OBSR52XXXD Series Fan
CUL Model NO. : 3OBSR52XXXD

Attach sales receipt to this card and retain as your proof of purchase

DATE OF PURCHASE: MODEL NUMBER:

RETAILER NAME: RETAILER ADDRESS:

To register your fixture, please visit our website www.montecarlofans.com

6.9 kg 15.18 lbs
Total fan weight with light

Cautions and Warnings
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70), including fire-rated construction. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and pushed carefully up into the outlet box. WARNING: Before you begin installing, servicing or cleaning the fan unit, switch the power off at the service panel and lock the service panel to prevent the power from being switched back on accidentally. If the service panel cannot be locked to prevent the power from being switched on accidentally, securely fasten a warning sign to the service panel. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or less” and use mounting screws provided with the outlet box. CAUTION: Comply with local codes and regulations. If installing the secondary support safety cable in the U.S., do not remove knockouts in the outlet box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the building structure or the ceiling joist. WARNING: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades. Attach the mounting bracket using only the hardware supplied with the outlet box. WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. UC9031 manufactured by Rhine Electronic Co., Ltd. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any other solid state fan speed control device, or variable speed control. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. Never place a switch where it can be reached from a tub or shower. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. CAUTION: To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing the light kit. CAUTION: The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the product should be returned to an authorized service facility for examination or repair. All set screws must be checked and tightened where necessary before installation.
Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers
Customer Service 800-969-3347
Customer Service Center 7400 Linder Ave. Skokie, IL 60077
www.montecarlofans.com

2 © 2022 Monte Carlo Fan Collections

11/2022

1

2

3

ON ON OFF OFF

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. Use AC 120V/60HZ power supply only.

Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. (Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan support and use only the screws provided with the outlet box (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member ( a loose box will cause the fan to wobble).

4

5

6

Mounting bracket

Downrod

Cross pin Yoke

Keeper pin

Canopy
Canopy bottom cap Yoke cover Downrod

Install the mounting bracket onto the outlet box. Partially loosen the two screws on the outlet box, attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration. Have the mounting bracket in position and tighten the set screws.

Partially loosen downrod set screws from yoke at top of motor assembly. Remove preassembled keeper pin and cross pin from downrod. Keep parts

Place downrod over canopy, canopy bottom cap and yoke cover. Thread lead wires and safety cable from motor assembly through downrod.

3 © 2022 Monte Carlo Fan Collections

11/2022

7

8

9

SAFETY CABLE INSTALLATION

Keeper pin

Cross pin

Tab

Lag screw

Slot

Safety cable

Washer Lock washer

Slip downrod into motor housing yoke, aligning holes and install cross pin and keeper pin. Insert cross pin through yoke and downrod until point appears on the other side, and insert keeper pin on cross pin. Pull the downrod up tight against the cross pin, and then evenly tighten the downrod set screws on motor housing yoke. Place yoke cover on top housing of fan. Warning: Cross pin and keeper pin must be installed securely, failure to install them will result in serious injury.

Install ball end of downrod into mounting bracket opening. Align (engage) slot on ball with tab on mounting bracket. Warning: Failure to align slot on ball with tab may result in serious injury. Important: If using the angle mount, make sure open end of mounting bracket is installed facing the higher point of the ceiling and make sure the ceiling angle is not steeper than 20º. Longer downrod may be necessary allowing the fan blades to rotate without obstructions.

For Canadian installation and for USA fan and light kit combinations over 35 lbs, in both flush and downrod modes the safety cable must be installed into the house structure beams using 3″ lag screws, washers and lock washers provided. Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires. Note: If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.

10
Black (Live) White (Neutral)
To Wall Outlet Box
Blue Ground/Green Ground/Green Blue Black White

11 Grounded wires

12
Ungrounded wires
Step screw

Step screw

Canopy bottom cap

Refer to page 7 for wiring, installation and operation of Wall controller. Do not operate the fan or light until it is installed completely.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box.

Partially loosen one and remove one preassembled step screw from mounting bracket (Do not remove the other set screws). Save the screw. Lift canopy up, aligning its keyhole slot with the preassembled step screw on mounting bracket and twist clockwise to lock in place. Reinstall the other step screw and tighten the screws securely. Attach canopy bottom cap onto canopy by aligning its holes with the step screws on mounting bracket and fix it with the magnet embraced.

4 © 2022 Monte Carlo Fan Collections

11/2022

13

14

15

Blade

Plate on motor

Light pan

Insert blade into the slot on flywheel. Install blade with screws and washers provided, aligning each of the holes as shown and tighten all screws securely. Repeat this process for remaining blades.

Loosen 2 and remove 1 preassembled screw from the plate on motor. Save screw for later use.

Place the lead wires from fan over the central hole of light pan Aligning the keyhole slots on the light pan with the preassembled screws on the plate. Twist clockwise till lock. Reinstall the screw removed in installation step 14. Tighten all screws securely.

16

17

18

light fixture

4000K 3000K 2700K

Color temperature converted switch

Loosen 2 and remove 1 preassembled screw from light pan. Save screw for later use.
© 2022 Monte Carlo Fan Collections

Connect white wire from fan to white wire from LED light fixture and then connect blue (or black) wire from fan to black (or blue) wire from LED light fixture. Be sure plugs connection clasped together firmly. Attach LED light fixture onto the light pan, aligning the keyhole slots on the LED light fixture with the preassembled screws on the light pan. Twist clockwise till lock. Reinstall the screw which was just removed. Tighten all screws securely.
This light kit includes 2700 (Warm white),
3000 (Soft white) and 4000K (Daylight)
correlated color temperatures (CCT). Get
desired CCT by operating the converted
switch.
5

Attach light shade by locating dimples in light pan with grooves on the light shade and twist clockwise until tight.
11/2022

19
Reverse switch
Setting the reverse switch on the left hand side will result in downward airflow and setting the switch on the right hand side will result in upward airflow. Note: Reverse switch must be set either way completely. If the reverse switch is set in the middle position, fan will not operate.

6 © 2022 Monte Carlo Fan Collections

11/2022

Wall Control Wiring, Installation and Operation
Warning: Before proceeding, be sure to shut off electricity at main switch or circuit breaker in order to avoid electrical shock.
Note: Before installing the wall transmitter, place it in OFF position. (Fig.2)
Make series-wound connection for the wall controller with HOT wire from house and lead wires from fan.
Connect the black/white wire marked “AC IN L” from wall controller to the HOT wire from house and then connect the black wire marked “TO MOTOR L” of wall controller to the fan lead wire from fan in outlet box. Connect the blue wire marked “FOR LIGHT” from wall controller to the light lead wire from fan (fan with light)
Connect green/yellow grounded wire to grounded wire from outlet box.
Install the wall controller to outlet box using machine screws provided.
Attach wall plate to wall control unit with screws provided. (Fig.1)

WHITE (Neutral)
120V/60HZ Power supply BLACK (Live)

BLUE BLACK

Operation
This wall controller provides 4 fan speeds, light on/off and light dimming control.(Fig.2)
1 – High – , 2 – Medium high , 3 Medium , 4 – Low , – Off.
Light on/off and dimming.

Wall controller
Black/White(AC IN L) Blue (FOR LIGHT) Black (TO MOTOR L)

Wall plate

Outlet box Green/Yellow (Grounding)

Fig.1

ON and Dimming Off
Fig.2
7 © 2022 Monte Carlo Fan Collections

11/2022

Troubleshooting

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

installation, please call our Customer Service Center at the number printed on your parts list insert sheet.
Warning and lock the service panel to prevent the power from being switched back on accidentally. If the service panel cannot be locked to prevent the power from being switched on accidentally, securely fasten a warning sign to the service panel.

Trouble

Suggested Remedy

1. If fan does not start: 1. Check main and branch circuit fuses or circuit breakers. 2. Check line wire connections to fan and switch wire connections in switch housing.
CAUTION

either way. Fan will not operate when switch is in the middle. 4. If this fan uses a remote controller, make sure dip switches are in the correct setting and make sure the battery works.

2. If fan sounds noisy:

1. Check to make sure all screws in motor housing are snug (not over tightened). 2. Check to make sure the screws which attach the fan blade holder to the motor are tight. 3. Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. CAUTION 4. Check to be sure lightbulb is tight in socket and not touching the glass shade. 5. Some fan motors are sensitive to signals from Solid State variable speed controls. 6. Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear after this period.

3. If fan wobbles:

1. If this is a downrod mount fan, make sure the ridge on mounting bracket engages the notch in the downrod ball. 2. Make sure that canopy, mounting bracket or mounting plate are tightened securely to

4. Check that all blade holders are tightened securely to motor. 5. Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure this distance from blade tip to ceiling. Keeping measure within 1/8″, rotate the fan until the next blade is positioned for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer (not supplied) between the blade and blade holder at the screw closest to the motor. To adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at the two screws farthest from the motor. Reverse the position of the washer if blades mount from top of blade. 6. If blade wobble is still noticeable, interchanging two adjacent blades can redistribute the weight and possibly result in smoother operation. If the above steps do not eliminate the wobble problem, you will need to dynamically balance your fan with balancing kit provided.
4. If light does not work: 1. Check blue wire from fan to make sure it is connected to hot wire from house. 2. Check for loose or disconnected wires in fan switch housing. 3. Check for loose or disconnected wires in light kit. 4. Check for faulty lightbulb and make sure bulb is tight in socket. 5. Remove light kit and check the plug connections if they are present. 6. If this fan uses a remote controller, make sure dip switches are in the correct setting and make sure the battery works.
CAUTION: Make sure main power is turned off before entering switch housing and/or canopy.

8 © 2022 Monte Carlo Fan Collections

11/2022

Nov.2022

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals