Hygiplas Digital Fridge/freezer Thermometer Handleiding User Manual

Hygiplas Digital Fridge/freezer Thermometer Handleiding User Manual

HYGIPLAS Digital Fridge/Freezer Thermometer Handleiding

Safety Tips

  • Clean the probe immediately after each measurement to avoid cross contamination.
  • Do not expose the appliance to temperatures over 50ºC/122ºF or use in ovens

Installation

Battery
  1. Open the battery compartment on the bottom of the appliance.
  2. Remove the insulation strip and close the battery cover.
Wall Mount Appliance
  1. Clean the surface area where the appliance is to be mounted.
  2. Attach the velcro pads to the mounting surface and to the back of the appliance and join together.
Wall Mount Sensor
  1. Clean the surface area where the appliance is to be mounted.
  2. Attach the double-sided tape to the sensor holder and fix in place
    or
    Fix the sensor holder using the screw provided.

Operation

Temperature Measurement
  1. Press the IN/OUT button to select either the sensor in the appliance (IN) or the probe (OUT) to read the temperature.
  2. The correct temperature is displayed when the value remains constant.
Units of Measurement
  1. Press the red ºC/ºF button on the back of the appliance to alternate between Centigrade and Fahrenheit.
Maximum/Minimum Readings

The thermometer can store and display the maximum and minimum temperature readings taken since the last reset:

  1. Press the IN/OUT button to select the required temperature reading.
  2. Press the MAX/MIN button. The MAX icon and the maximum temperature taken displays on the screen.
  3. Press the MAX/MIN button again. The MIN icon and the minimum temperature taken displays on the screen.
  4. Press the button again to resume normal operation.
Note: To reset the memory press and hold the MAX/MIN button. A beeps sounds when the memory is reset. Always reset the memory before taking new readings to ensure accurate readings.
High/Low Temperature Alarm (OUT sensor only

The thermometer can sound an alarm when a set temperature range is exceeded.

  1. Press and hold the ALARM SET button. The HIGH value flashes on the display.
  2. Press and hold the ºC/ºF button to scroll to the required HIGH temperature.
  3. Press the ALARM SET button to then display the LOW temperature.
  4. Press and hold the ºC/ºF button to scroll to the required LOW temperature.
  5. Press the ALARM SET button to store the settings.
Note: When the alarm sounds; press the ALARM SET button to turn it Off.

Technical Specification

Temperature range-10 ~ 50ºC/ 14 ~ 122ºF (IN)
-50 ~ 70ºC/-58 ~ 158ºF (OUT)
Temperature reading accuracy± 1.5ºC/2.7ºF
Resolution0.1º over full range
Temperature display refresh rate10 seconds
Display size20(h) x 47(w) mm
BatteryAAA
Probe cable length3 metres
Thermometer dimensions (hxwxd)52.5 x 73.5 x 18 mm
Ambient operating temperature52.5 x 73.5 x 18 mm

Compliance

Dispose of depleted batteries in accordance with local regulations, within the
EC there are nominated disposal points for batteries.
The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your
your area.

HYGIPLAS parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
HYGIPLAS products have been approved to carry the following symbol:

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of HYGIPLAS.
Every effort is made to ensure all details are correct at the time of going to press, however, HYGIPLAS reserve the right to change specifications without notice.

DECLARATION OF CONFORMITY

Equipment TypeModel
Digital Fridge Freezer ThermometerF343
Application of Territory Legislation & Council Directives(s)Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU recast of 2004/108/EC EN 61326-1
Restriction of Hazardous Substances Directive (RoHS) 2015/863 amending Annex II to Directive 2011/65/EU
Producer NameHygiplas

The undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and Standard(s).

Date7th January 2021
Signature
Full NameAshley HooperEoghan DonnellanJosie Holt
PositionTechnical & Quality ManagerCommercial Manager/ ImporterCommercial Manager/ Responsible Supplier
Producer AddressFourth Way, Avonmouth, Bristol, BS118TB United Kingdom42 North Point Business Park New Mallow Road Cork Ireland15 Bagdally Road, Campbelltown SW2560

 

UK0845 146 2887
Eire
NL040 – 2628080
FR01 60 34 28 80
BE-NL0800-29129
BE-FR0800-29229
DE0800 – 1860806
ES901-100 133
PTv[email protected]
AU1300 225 960

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.