global sources HY312 Series Touch Screen Programmable Heating Thermostat User Manual - Manualsee

global sources HY312 Series Touch Screen Programmable Heating Thermostat User Manual

HY312 Series Touch Screen
Programmable Heating Thermostat

HY312 Series

Product Summary

This new design heating thermostat aims at market demand, it has large LCD display. Easy operation, complete functions .It can be control motorized ball valve, motorized valve, thermal valve, solenoid valve, heater, electric heating film, electric heating carbon crystal. It is used for floor heating.

Technical Data

  • Power Supply: AC200-240V, 50/60HZ (can customize 110V,24V,12V)
  • Load Current: 3A(Water Heating); 16A(Electric Heating)
  • Accuracy: ±1ºC
  • Set-point Temperature Range: 5ºC – 35ºC
  • Limit Temperature Range: 5-99℃
  • Consumption: <1.0W
  • Temperature Sensor: NTC

Features

  • Large LCD touch screen with blue backlight display and double temperature display mode
  • Time display (minutes, hours, weeks)
  • 6 period programmable controlling temperature setting
  • Internal and external temperature sensor for choice
  • Room temperature display precision is 0.5,inner precision is 0.1
  • Setting temperature meet user’s demand of room temperature
  • Memory function when power failure, protect your setting from power failure
  • Room temperature automatically calibration function

Button description

Button description

Function and display

Function and display

Operation diagram

Operation diagram

Time and time interval setting

Time and time interval setting

Time interval programming

Time interval programming

Time interval programming

  1. The factory default temperature value of time interval 3 and 4 are the same as period 2,please modify default temperature when it’s necessary.
  2. Setting temperature is“00”, this time interval is shutdown.
  3. View out temperature value (floor temperature)
    (1)Touch screen version: when internal control temperature and external limit temperature(high temperature protection),under power on state, press time key not move first, then press on/off key together to switch and view external temperature (this time measure temperature display zone displays OUT TEMP temperature value),press time key to display room temperature;

Advanced Setting(suggestion: operated by technician)

Advanced Setting

Note: hysteresis (return temperature) description: the factory default of external sensor limit temperature(OSV) set as 42℃, external sensor limit temperature hysteresis(dIF) set as 2,when temperature up to 44℃,relay stop output, when temperature drops to 40℃,relay output again and heating.(operation when room temperature lower than setting temperature)

Sensor fault hint

Please select internal, external sensor working mode correctly. If it is choose wrong or sensor is fault (breakdown),LCD  interface will display “Err” ,temperature controller stops heating until fault is eliminated. Special Hint :installation cable

Please select: water heating selects 1.5-2.5mm2 rigid line; electric heating select above 2.5mm2 rigid line.

Power wiring diagram

Advanced Setting

Note: 3 & 4 connect with power, 5 & 6 connect with gas boiler,1& 2 connect with thermal actuator, please do not connect 1&2 to gas boiler,If you connect it wrongly, there will be Short circuit.