Wonderfire FFB Fire Fan Box
Product Information
The WONDERFIRE FFB (Fire Fan Box) is a gas coal firebox designed
for decorative purposes. It is approved to be installed as a zero
clearance firebox and operates on Natural Gas. The product is not
certified as a space heater. The firebox is covered by a warranty,
which includes a 10-year warranty period for defects in the firebox
of the gas burner, and a 2-year warranty period for defects in the
gas valves or coals.
Usage Instructions
- Installation: The installation of this
appliance should only be carried out by an authorized person in
accordance with the Manufacturer’s Instructions, local gas fitting
regulations, AS/NZS5601.1-2013 installation code for gas burning
appliances, and any other relevant statutory regulations. Ensure
that the installation meets the requirements set out in
AS/NZS5601.1-2013. - Initial Use: When using the fire for the first
time, it is recommended to open windows in the room to allow any
slight smell from the heat resistant paint curing to dissipate. A
slight discolouration inside the firebox may occur, which is normal
and not covered by warranty. - Safety Precautions: Do not place articles on
or against the appliance and avoid using or storing flammable
materials near it. Avoid spraying aerosols in the vicinity of the
appliance while it is in operation. Ensure that any return air
register or exhaust system does not adversely affect the operation
of the appliance or the draught of chimney or flue. Do not modify
the appliance. It is designed to operate with luminous flames,
which may exhibit slight carbon deposits. - Ventilation: The room where the fire is
located must have permanent ventilation while the fire is in
operation. The room should have a minimum cross-sectional area of
40,000 square millimeters of effective ventilation. - Service: It is recommended to service the gas
fire every 2 years.
WARNING: The WONDERFIRE FFB is primarily a
decorative appliance and is not certified as a space heater.
WONDERFIRE FFB (Fire Fan Box)
INSTALLATION & OPERATING MANUAL
Nectre Wonderfire fire boxes are approved to be installed as a zero clearance firebox and are designed to operate on Natural Gas. Approval Number: AGA 4464 G
Installed primarily as a decorative appliance. Not certified as a Space Heater. VERSION 1.5
WARRANTY INFORMATION
The benefits provided to you under the following warranty are in addition to any other rights and remedies available to you under the law. 1. Warranty If: (a) during the first 10 years from the date of purchase (Firebox Warranty Period), there is a defect in the firebox of the
Gas Burner; or (b) during the first 2 years from the date of purchase (Parts Warranty Period), there is a defect in the gas valves or
other parts of the Gas Burner, due to improper workmanship or material, Glen Dimplex will replace or repair the Gas Burner without charge. Any replacement product is warranted only for the time remaining on the original Firebox Warranty Period or the Parts Warranty Period as relevant. 2. Registration All in and out of warranty claims and service requests are to be emailed to: [email protected] The email should include the following information: · Proof of purchase–A copy of the customer’s invoice. · Store details and contact person. (Please ensure ALL details are correct) · All relevant customer details, if not on the proof of purchase · Detailed report of the issue with pictures where possible showing any damage or technical issue. 3. Exclusions Glen Dimplex is not obliged to replace or repair the Gas Burner under clause 1 if: (a) it has been improperly stored, installed, connected, used, operated or repaired, or damaged, abused, tampered with, altered (without our written approval), or not maintained in strict accordance with our installation and operating instructions; or (b) it has been installed in an outdoor setting. 4. Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Gas Burner only, at our option. To the extent permitted by law, Glen Dimplex excludes liability for consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever, and damage arising from normal wear and tear. 5. Claiming under the Warranty In order to claim under this warranty you must, within the Firebox Warranty Period or the Parts Warranty Period (as relevant), contact Glen Dimplex, providing the original proof of purchase and the details below:
Supplier Name___________________________________________________________________________ Date Of Purchase / settlement of property if new home _________________ Model / Serial Number_______________________ This warranty does not cover the cost of claiming under the warranty or transporting the Real Flame Gas Burner to and from the supplier.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. If you would like to speak to someone about your Gas Burner or claiming under this warranty, please contact the Service Warranty Desk on 1300 554 155.
Glen Dimplex Australia Pty Ltd ACN 69 118 275 460 Head Office: 183L4a0keFveiernwtrDereivGe,uSllcyoRreosabdy,,VSICco3r1e7s9by 3179 Telephone: 1300 554 155 Facsimile: (03) 8706 2001
2
INSTALLATION NOTICE
The installation of this appliance is only to be carried out by an authorised person in accordance with the Manufacturer’s Instructions, local gas fitting regulations, AS/NZS5601.1-2013 installation code for gas burning appliances and any other relevant statutory regulations.
In all cases the installation of this appliance shall meet the requirements as set out in AS/NZS5601.1-2013
NOTE: A slight smell may be apparent for the first few hours of use. This is due to the heat resistant paint curing. It is recommended to open windows in the room for the first lighting of the fire. In some instances a slight discolouration may occur inside the firebox. This is a normal condition and is not covered by warranty.
IMPORTANT SAFETY NOTICES
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE. DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION. CARE MUST BE TAKEN TO ENSURE THAT ANY RETURN AIR REGISTER OR EXHAUST SYSTEM DOES NOT ADVERSELY AFFECT THE OPERATION OF THE APPLIANCE OR DRAUGHT OF CHIMNEY OR FLUE. DO NOT MODIFY THIS APPLIANCE. THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES. THIS MAY EXHIBIT SLIGHT CARBON DEPOSITS.
VENTILATION REQUIREMENTS
Permanent ventilation of the room where the fire is to be situated is essential while fire is in operation. The room must have a minimum cross sectional area of 40,000sq mm of effective ventilation.
It is recommended that you service your gas fire every 2 years.
WARNING
This firebox has a naked flame, care should be taken when it is operating if children or the infirm are in close proximity. For protection of young children or the infirm, a secondary guard is required. A safety screen is recommended if constant supervision is not possible. It is recommended that a secondary guard complying with AS-NZS2286 be installed. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilitites, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
THIS IS PRIMARILY A DECORATIVE APPLIANCE AND IS NOT CERTIFIED AS A SPACE HEATER.
3
CONTENTS
Contents …………………………………………………………………………………………………..4 User Instructions………………………………………………………………………………………..5 Installation Instructions ……………………………………………………………………………….6 Servicing Details ………………………………………………………………………………………..8 Glen Dimplex contact information……………………………………………………………….12
4
WONDERFIRE FFB (FIRE FAN BOX)
Congratulations on your purchase of the Nectre Wonderfire. This gas coal fire has been bench tested in the factory to ensure satisfactory operation.
Safety First! · The appliance is designed to simulate a coal fire and as such the front grate, the entire front
and top vent are working surfaces which can become quite hot. Do not touch them. Always take extra care with young children or the infirm. · THE GUARD IS FITTED TO THIS APPLIANCE TO REDUCE THE RISK OF FIRE OR INJURY FROM BURNS AND NO PART OF IT SHOULD BE PERMANENTLY REMOVED. · FOR THE PROTECTION OF YOUNG CHILDREN OR THE INFIRM, A SECONDARY GUARD IS RECOMMENDED. · DO NOT OPERATE WITH PANELS, COVERS, OR GUARDS REMOVED FROM THIS APPLIANCE. · PRIMARILY A DECORATIVE APPLIANCE – NOT CERTIFIED AS A SPACE HEATER. · Have the unit installed and serviced by a qualified person. · Wash hands after handling coals and ensure children do not handle them as the colouring may contain toxic dies.
Caring for Your Wonderfire FFB Your Wonderfire has been designed for ease of use and is very easy to maintain. The Fire is a sealed unit and there is no user serviceable components inside. To clean: · Metal surfaces; simply wipe over with a damp cloth. Do not use harsh cleaning agents or
solvents. · Ceramic coals; Lightly vacuum with a soft brush attachment. · Pilot Light; check for lint and dust, vacuum as necessary. · For units with a fan, check the air intake at the front of the Fire is free of lint and dust, clean as
necessary. · Do not attempt to clean the unit whilst it is operating (including Pilot Light) or whilst it is hot. · After a number of hours of use of the Fire, there may be a slight blackening of some parts of the
coals. This is normal and helps enhance the realistic coal fire look.
If Your Fire Needs Servicing Your Fire is reliably designed and built to a fully tested design. Please be assured that if you have any concerns, they will be resolved quickly and to your satisfaction. If the Fire has been only recently installed and fails to operate, you should call the installer to solve any problems. Check with the installer that installation has been carried out correctly, that the gas lines have been bled and gas cocks are turned on. If the problem is not related to the installation, please call your place of purchase and let them know what model you have installed and a description of the problem. If necessary, they will refer back to the manufacturer. If after some use the appliance fails to operate, you can telephone us direct: 1300 554 155.
5
OPERATING INSTRUCTIONS – Customer
Please refer to the “Nectre Wonderfire” Operating, Installation and Servicing Instructions.
INSTALLATION INSTRUCTIONS
TO THE INSTALLER
This appliance must only be installed by an authorized person in accordance with these instructions and with the AGA gas installation code. Please ensure that your workmanship, like ours, is of the highest quality so that our customer is fully satisfied with the installation and operation of this Gas Fire. If you have any questions please call us: 1300 554 155.
Preliminary · This appliance must be installed in accordance with the AGA Gas Installation Code AS5601 /
AG601 Clauses 5.12.13.2 to 5.12.13.5 and appropriate Australian Standards to meet the zero clearance rating. · The Nectre Wonderfire Gas Fire is only to be used with the gas type specified for the unit. · It is recommended that a secondary guard complying with AS 2286 be installed. · As always, ensure that loose fabrics such as curtains and furniture cannot touch the appliance. It is recommended that a fire guard be used with the appliance. · The spacers on the sides and back of the box are to provide clearance to combustible materials. · Do not allow combustible materials to touch the box. · There must be a minimum of 50mm gap between the gather and any combustible materials. · The front opening of the box is 500mm wide and 570mm high. · The overall dimensions of the box is 650mm wide, 300mm deep and 805mm high. (Dimensions include zero clearance spacers and the gather but not the facia or guardette if fitted). · Packaging and transit protection must be removed from the appliance prior to installation. This includes pallet, plastic wrap, temporary labels and foam protection.
Fitting the unit · If fitting to an existing fireplace, it must be at least 505mm wide, 275mm deep and 575mm
high to suit the Nectre fan forced convector box (with the zero clearance spacers removed). · The chimney should also be swept and inspected to see if it is in sound condition. · The chimney must be a minimum area of 22 000mm2 (e.g. 150x150mm if masonry or 150mm
diameter if round metal flue). · A 150mm AGA approved Gas Cowl must be fitted.
6
INSTALLATION INSTRUCTIONS
Fitting the unit
FITTIN·G TFOorAaNnEeXwISfirTeIpNlaGcOe,PuEtilNiziFnIgRtEhePLZAerCoEClearance Box, the dimensions are 650mm wide,
295mm deep and 570mm high, plus the gather, which is the same width and depth but adds THIS APPLI2A0N5CmEmREtQo UthIReEhSeFigRhEtSoHf tAhIeR uTnOitO. PERATE SAFELY. THE ROOM WHERE THIS APPLIANCE IS INSTALL·EDPMlaUcSeTthHeACVoEnPvEeRcMtorABNoExNTinVthEeNTdIeLsAirTeIOd NpoFsRitOioMn. OUTDOORS. THIS VENTILATION MUST
NOT BE ·MOCDhIFeIcEkDw. here timbers are located in the roof to ensure a clear path for the flue and maintain 25mm gap clearance.
Note
to
·InstFZaietllraeor1C5le0amramncfleuead(adct2iv0e0)mtomgecathseinr gw.itBheannd
AGA approved gas cowl to out four equidistant 25mm
the top tags at
of the flue. For the top of the
There
are
2
o1frp5et0eiomtnomsmffolourveinetsowtaicltlheininngtroaeuWitteoirnnfdltuheeerfit2roe0a0FFlmloBmw:
flue. Flash the outer flue to the roof. The for thermal expansion and contraction.
inner
flue
will
be
Type 1 ·In Tanheexroisotmingmfiursetphlaacveewtoithalafipxerodvveedndtirlatuiognhte/qwuoarlktiongthcehcimhinmenyey / flue area. · The gather should be sealed to the fan box using a high temp silicon or a high temp fire / flue
In this scenasreioa, ltahnet.existing fireplace must be at least 505mm wide, 275mm deep and 575mm high to suit the Wonderfire FFB (with the zero clearance spacers removed).
Gas and electrical The chimney should also be swept and inspected to see if it is in sound condition.
· Gas connection is to a ½” BSP fitting connected to the gas regulator. This is located at the RHS The chimneoyfmthuestubneita. 1m4in5immmumuparferaomof t2h2e,0b0a0smema2n(di.e8.0ammminfimroummthoef 1fr5o0nxt1.50mm if square or 150mm diameter· if rNoounted:)D, aondnomt ubsrtinegxttehnedgtaosashuepigphlyt odfoawtnletahset 2a.c4tmiv.e chimney.
A
150mm·
AGTthhAeeaRp2Hp4rS0ovvneeedlaeGrctatrhsiceCaogl wacsol mncnouensctntbeioecntfiioftonter,dt5h.0emfamnuisp
a cord with a standard 10A from the base and 140mm
three pin plug, from the front.
also on The gas
To of
2e.n4smuroeftflhcbeeoaxWintbtteolreornielddusuen,crfiiottrrOe(raReFFm2riB4go0iddtevraflacwuocesntsaotarsot1ails2cmfVahcoidmtdocenrilPelyoylunilngilnyaP)eTria.sycIpnskeu.thp1epinlmiestadajolblaryittiyaonob,faiitnttisestrrayellqaputaiiocrenkdscitotounautatsiieonnainsmg, iti8nwiAmilAlubmseize
more practical to use flexible duct over rigid flue.
Commissioning
Type 2 ·In Oa fnrcaemtehoeubtusrintueartiisofnittweidthaandrigcoidnnfaebcrtiecdatteodthfleuegas, test the unit’s operation.
Fsdioeorpnatshnabereuw· t6afi5Aagdr0eredfmeptnselmeea2r cr0n1aew5t0te,moiurdmrimtnei(il,gnEits2uo.it9gnhtet5.gehsmaetfolhmushepmeeedW,iogrebaokheytintpniodtogrnaefantrtvfwfihrdeoreisrem5sut7Finon0cFifgmBot.pltmd(ahw,peithetephirgseotthrhrif,moepsremzlufetiesorreorktpheoclefalmectgahaeraeattcsnhohpcep)ierl.el,asnwgpinheagic,ceih.oresri.sacatatlthlnaepcohrpsoeayddm, u)ue,csttwhisneigoddftahicmsoamemnndob-kuestion
Place the Wonderfire FFB in the desired position.
Check where timbers are located in the roof to ensure a clear path for the flue and maintain 25mm gap clearance. Fit a 150mm flue (active) together with an AGA approved gas cowl to the top of the flue. For Zero Clearance add 200mm casing. Bend out four equidistant 25mm tags at the top of the 150mm flue to centre it in the 200mm flue. Flash the outer flue to the roof. The inner flue will be free to move within outer flue to allow for thermal expansion and contraction.
The flue must extend to a minimum height of 2.4m.
The room must have total fixed ventilation equal to the chimney / flue area.
The gather should be sealed to the fan box using a high temp silicon or a high temp fire / flue sealant.
7
INSTALLATION INSTRUCTIONS (continued)
· An AGA approved 150mm diameter Gas Cowl must be fitted. · The flue or chimney of an open gas fire must be kept clear at all times. Devices which close or
temporally close the flue or chimney are not permitted. (e.g. a damper must be removed or securely disabled in the fully open position.) · If these conditions are met the chimney should usually provide satisfactory draw. In any event, the chimney and final installation must be tested for spillage into the room. This can be done by lighting a paper fire in the fireplace (before the appliance is installed) and holding a smoking twist of paper or a smoking match by the front of the fireplace. Air conditioning vents near the fireplace may also cause spillage. · The fireplace must be at least 470mm wide (front), 325mm wide (rear) x 250mm Deep x 400mm high to suit the Type 1 burner. · The room must have total fixed ventilation equal to the chimney / flue area. · Refer also to “Wonderfire FFB Convector Box” instructions if fitting a Convector Box.
Fitting the unit · The unit should be fixed to the base of the fireplace with a screw to each front corner of the
burner.
Gas · Gas connection is to a ½” BSP male fitting connected to the RHS of the valve. It is located
100mm from front, 45mm up from floor and 170mm in from front RH corner of the appliance · Thoroughly blow out the supply pipe to clear any dust and debris. · Ensure all connections are gas tight. · Note: Do not bring the gas supply down the active chimney.
Coals The WONDERFIRE has ceramic coals and a burner designed to appear like a coal fire. · The unit is supplied with the ceramics assembled ready for operation. · When the unit is unpacked check that no damage has occurred in transport. · Carefully place the ceramic coal assembly on top of the burner making sure that it sits in place
correctly. · No other coals should be added as this will adversely affect the performance of the fire. · Wash hands after handling the ceramic base or coal assembly.
Commissioning · Once the fire is fitted and connected to the gas, test the unit’s operation. · After 10 minutes operation from cold, test for fireplace spillage, i.e. all products of combustion
are entering the flue, by traversing the perimeter of the opening or canopy, using a smoke generator (E.g. a smoking twist of paper or smoke match).
88
SERVICING / MAINTENANCE / FAULT FINDING DETAILS
Please refer to the “Nectre Wonderfire” Operating, Installation and Servicing Instructions.
WIRING DIAGRAM
89
10
11
GLEN DIMPLEX AUSTRALIA PTY LTD
ABN 69 118 275 460
Head Office/FHaecadtoOrfyfi/cSehowroom 8 L1a3k4e0vieFweDrnritvree,eScGoruelslybyR, VdI.C 3179 Scoresby Vic 3179